Description

Application

The Proline Promag 55S is designed for measuring inhomogeneous, abrasive, and corrosive fluids. Its robust sensor, equipped with industry-optimized liners, makes it ideal for challenging environments such as sewage treatment plants, pulp and paper manufacturing, and the primary and metals industries. Thanks to its high-performance transmitter, the Promag 55S not only ensures reliable flow measurement but also calculates solids content with minimal maintenance needs.

Its bidirectional measuring principle is unaffected by pressure, density, temperature, or viscosity, making it well-suited for demanding applications involving high solids content and significant abrasion.

Device Properties:

  • Enhanced coil system
  • Wide selection of liners
  • Measures solids content up to 80% by weight
  • 4-line backlit display with touch control
  • Two switch outputs
  • Compatible with HART, PROFIBUS PA/DP, and FOUNDATION Fieldbus

Benefits

  • Outstanding signal stability thanks to advanced signal processing
  • Maximum safety with industry-optimized measuring electrodes and linings
  • Energy-efficient flow measurement with no pressure loss due to cross-section constriction
  • Maintenance-free operation with no moving parts
  • Exceptional performance, including integrated solids measurement for challenging fluids
  • Enhanced safety with built-in electrode cleaning
  • Automatic data recovery during servicing for added convenience

 

SPECIFICATIONS

Pressure Specifications

Measuring principle Electromagnetic
Product headline

The flowmeter with outstanding abrasion resistance and integrated solids content diagnostics.

Superb signal stability due to unique signal processing.

Ideal for the most demanding applications with high solids content and high abrasion.

Sensor features

Maximum safety – industry-optimized measuring electrodes and linings. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.

Intensified coil system. Large range of liners. Solids content up to 80 % by weight.

Transmitter features

Highest performance – with integrated solids measurement for demanding fluids. Highest safety – integrated electrode cleaning. Automatic recovery of data for servicing.

4-line backlit display with touch control. Two switch outputs. HART, PROFIBUS PA/DP, FOUNDATION Fieldbus.

Nominal diameter range

DN 15...600

1/2"...24"

Wetted materials

Liner: Polyurethane, Hard rubber, PFA, PTFE, Natural rubber

Electrodes: 1.4435/304L, Alloy C-22, Tantalum, Platinum, Duplex 1.4465, Tungsten carbide, Titanum

Measured variables Volume flow, electrical conductivity, mass flow
Max. measurement error

Volume flow: ±0.5 % o.r.± 1 mm/s (0.04 in/s)

Option: ±0.2 % o.r. ± 2 mm/s (0.08 in/s)

Measuring range 0.06 dm3/min to 600 m3/h (0.015 gal/min to 2650 gal/min)
Max. process pressure PN 40, Cl. 300, JIS 20 K
Medium temperature range 0 to +60 °C (+32 to +140 °F), 0 to +80 °C (+32 to +176 °F), –20 to +50 °C (–4 to +122 °F), –20 to +180 °C (–4 to +356 °F), –20 to +150 °C (–4 to +266 °F)
Ambient temperature range –40 to +60 °C (–40 to +140 °F)
Sensor housing material Aluminum coated AlSi10Mg, carbon steel with protective varnish
Transmitter housing material Powder-coated die-cast aluminum
Degree of protection

Standard: IP 67 (Type 4X enclosure) for transmitter and sensor

Optional: IP 68 (Type 6P enclosure) for remote version of Promag S sensor

Display/Operation

Liquid-crystal display: illuminated, four lines with 16 characters per line

Onsite operation with three optical sensor keys

Outputs

4...20mA

(active/passive) Pulse-/ Frequency output (active/passive)

Two status outputs

Inputs

Status

Current input

Digital communication HART, PROFIBUS DP/PA, FOUNDATION Fieldbus
Power supply

AC 20 to 260 V

DC 20 to 64 V

Hazardous area approvals ATEX, FM, CSA, UK Ex
Product safety

CE, C-tick, EAC marking

Pressure approvals and certificates CRN, PED
Material certificates 3.1 material
Hygienic approvals and certificates Drinking water approval:ACS, KTW/W270, NSF 61, WRAS BS 6920

 

Documents