null
Endress+Hauser

Absolute and gauge pressure Cerabar PMP51 SERIES

(No reviews yet) Write a Review
SKU:
Absolute and gauge pressure Cerabar PMP51SERIES
Weight:
0.00 Grams
Call us: +971 4 259 5133

Description

Application

The Cerabar PMP51 digital pressure transmitter, featuring a metal membrane, is ideal for use in both process and hygienic applications, providing precise measurement of pressure, level, volume, or mass in liquids or gases. It is specifically engineered for high-pressure environments, capable of handling pressures up to 400 bar. The device offers a Quick Setup feature with an adjustable measuring range, enabling straightforward commissioning, which helps to minimize costs and save time. It is certified to SIL2 standards according to IEC 61508 and IEC 61511.

The PMP51 is housed in a single-chamber design, available in either aluminum or stainless steel (316L).

Process Connections: Available in threaded, flanged, or hygienic options.

Process Temperature: Operates within a range of -40 to +130°C (-40 to +266°F), with the capability to handle up to 150°C (302°F) for one hour.

Measuring Range: From -1/0 to +400 bar (-15/0 to +6,000 psi).

Accuracy: ±0.1%, with an enhanced "Platinum" accuracy of ±0.075%.

The device also meets international standards for explosion protection, SIL certification, hygienic approvals, and marine approvals.

 

 


 

 

Benefits

  • Provides highly accurate process value measurements, even with fluctuating process temperatures.
  • Ensures process safety with compact, flush-mounted process connections suitable for hygienic applications.
  • Supports process pressure monitoring up to SIL2, with certification in line with IEC 61508 and IEC 61511 standards.
  • Features a modular design, allowing for easy replacement of the display or electronics as needed.
  • Simplifies commissioning with an intuitive, menu-guided interface accessible via the on-site display, supporting 4 to 20mA with HART, PROFIBUS PA, and FOUNDATION Fieldbus protocols.
  • Enables seamless and independent integration into systems (HART/PA/FF).
  • Available with pre-mounted manifolds that are guaranteed to fit and have been tested for leaks.

SPECIFICATIONS

Pressure Specifications

Measuring principle Absolute and gauge pressure

Characteristic

Smart and reliable pressure transmitter, with piezoresistive measuring cell

and metal welded process isolating

diaphragm

Supply voltage

4...20mA HART

11,5...45V DC (Non Ex):

Ex ia: 11,5...30V DC

PROFIBUS PA:

9...32 V DC (Non Ex)

FOUNDATION Fieldbus:

9...32 V DC (Non Ex)

Reference Accuracy

Standard 0.1%

Platinum 0.075% 

Long term stability

0.1% of URL/year

0.2% of URL/ 5 years

0.25% of URL/ 10 years

Process temperature

 

-40°C...+130°C

(-40°F...+266°F

+150°C for 1h

(+302°F for 1h)

Ambient temperature

 

-40°C...+85°C

(-40°F...+185°F)

Measuring cell

 

400mbar...400bar

(5.8 psi...6000psi)

relative/ absolute

Smallest calibratable span 20 mbar (0.3 psi)

Vacuum resistance

 

10 mbar (0.15 psi)

Max. Turn down

 

20:1
Max. overpressure limit

600bar (9000psi)

Process connection

Thread:

G1/2...G2, MNPT1/2...MNPT2

Flange:

DN25...DN80,

ASME 1 1/2"...4",

Process connection hygienic

Tri-Clamp

DIN11851

NEUMO

Varivent N

SMS

DRD

Material process membrane

316L, AlloyC,

Rhodium>Gold

Material gasket

None, measuring cell welded

Fill fluid

 

Silicone oil,

Inert oil

Material housing

Die-cast aluminum,

AISI 316L

Communication

 

4...20 mA

4...20 mA HART

PROFIBUS PA

FOUNDATION Fieldbus

IO-Link

Certificates / Approvals

ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex

Safety approvals SIL
Design approvals

EN10204-3.1

NACE MR0175

Hygienic approvals

3A, EHEDG

CoC ASME-BPE

Marine approvals GL/ ABS/ LR/ BV/ DNV
Drinking water approvals

NSF

Successor PMP51B

Continuous / Liquids Specifications

Measuring principle

Absolute and gauge pressure

Characteristic / Application

Smart and reliable pressure transmitter, with piezoresistive measuring cell

and metal welded process isolating

diaphragm

Supply / Communication

 

4 ..20 mA HART:

11,5...45 V DC

Ex ia: 11,5...30 V DC

PROFIBUS PA

FOUNDATION Fieldbus

Accuracy

Standard 0.1%

Platinum 0.075%

Long term stability

< 0,1% von URL/ year

0,2% of URL/ 5 years

0,25% of URL/ 10 years

Ambient temperature

-40°C...85°C

(-40°F...185°F)

Process temperature

-40°C...130°C

(-40°F...266°F)

Process pressure / max. overpressure limit

600 bar (9000 psi)

Pressure measuring range

1 bar...400 bar

(15 psi...6000 psi)

Main wetted parts

316L

Process connection

Threads

Flanges (DIN, ASME, JIS)

Hygienic connections

Tri-Clamp ISO2852

Max. measurement distance

4000 m (13.123 ft) H2O

Communication

4...20 mA HART

PROFIBUS PA

FOUNDATION Fieldbus

IO-Link

Certificates / Approvals

 

ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI

Safety approvals

 

SIL

Design approvals

 

EN 10204-3.1

NACE MR0175, MR0103

AD2000

Hygienic approvals

3A, EHEDG

CoC ASME-BPE

Marine approval

GL/ ABS/ LR/ BV/ DNV

Drinking water approvals

NSF

Options

Local display

Successor

PMP51B

Application limits

Measuring cell: Metal welded

If pressurized, possibly use differential pressure meas-urement with two pressure transmitters (electronic dp). Observe ratio head pressure : hydrostatic pressure

 

Documents

You may want to read this product's catalog. If so, please click to view the Endress+Hauser Absolute and gauge pressure Cerabar PMP51 Series datasheet.