Description

Application 

The Cerabar PMP71 is a digital pressure transmitter featuring a metallic membrane, ideal for various process applications including pressure, level, volume, or mass measurement in both liquids and gases. It is specifically engineered for high-pressure environments, supporting applications up to 700 bar. The device offers a Quick Setup feature, allowing for freely adjustable measuring ranges without requiring specific pressure inputs. It is designed in accordance with IEC 61508 standards, making it suitable for use in SIL2/3 safety systems, and it comes with a MID Parts Certificate, making it appropriate for custody transfer applications.

The transmitter is housed in a robust two-chamber aluminum or 316L stainless steel casing.

Available process connections include thread and flange options.

It operates within a process temperature range of -40 to +125°C (-40 to +257°F).

Measuring ranges span from -1/0 up to 700 bar (-15/0 up to +10,500 psi).

The device offers high accuracy, with a standard of ±0.05%, and a "Platinum" accuracy option of ±0.025%.

It also comes with international explosion protection certifications, WHG overfill prevention, hygienic and marine approvals, and SIL compliance.

 

 


 

Benefits

  • Delivers exceptional accuracy, reproducibility, and long-term stability.
  • Ensures maximum safety with a gas-tight feedthrough, capable of supporting SIL2/3 applications, certified to IEC 61508 standards.
  • Features an easy, menu-guided setup process via a local display, supporting 4 to 20 mA with HART, PROFIBUS PA, and FOUNDATION Fieldbus communication protocols.
  • Includes the HistoROM data management concept, facilitating quick and straightforward commissioning, maintenance, and diagnostics.
  • The device is overload-resistant and continuously monitors functionality from the measuring cell to the electronics.
  • Available with pre-mounted manifolds that are fully tested for leaks, ensuring a perfect fit.
  • Offers seamless and independent system integration through HART, PROFIBUS PA, or FOUNDATION Fieldbus.

SPECIFICATIONS

Pressure Specifications

Measuring principle Absolute and gauge pressure

Characteristic

Digital transmitter with piezoresistive sensor and welded metallic membrane

Modular transmitter

Long term stability

Enhanced safety via self diagnostic functionsSecondary process barrier

Supply voltage

4...20 mA HART

10,5...45V DC (Non Ex):

Ex ia: 10,5...30V DC

PROFIBUS PA:

9...32 V DC (Non Ex)

FOUNDATION Fieldbus:

9...32 V DC (Non Ex)

Reference Accuracy

Standard: 0.05%

Platinum: up to 0.025%

Long term stability

0.05 % of URL/ year

0.07 % of URL/ 5 years

0.1 % of URL/ 10 years

Process temperature

-40°C...125°C

(-40°F...257°F)

Ambient temperature

-50°C...85°C

(-58°F...185°F)

Measuring cell

400 mbar...700 bar

(5.8 psi...10.500 psi)

relative/ absolute

Smallest calibratable span

5 mbar (0.075 psi)

Vacuum resistance 10 mbar (0.15 psi)

Max. Turn down

100:1
Max. overpressure limit 1050 bar (15.750 psi)
Process connection

Thread:

G1/2...G2, R1/2, MNPT1/2...MNPT2, R1/2

Flange:

DN25...DN80,

ASME 1"...4",

JIS 10K...20K

Material process membrane

316L, AlloyC,

Rhodium> Gold

Material gasket None, measuring cell welded
Fill fluid

Silicone oil,

Inert oil

Material housing

Die-cast aluminum,

AISI 316L

Communication

4...20 mA HART

1- 5V DC Low Power

PROFIBUS PA

FOUNDATION Fieldbus

Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC, UK Ex
Safety approvals SIL
Design approvals

EN10204-3.1

NACE MR0175

Marine approvals

GL/ABS

Drinking water approvals NSF
Specialities Diagnostic functions
Successor PMP71B

Continuous / Liquids Specifications

 

Measuring principle Absolute and gauge pressure
Characteristic / Application

Digital transmitter with piezoresistive sensor and welded metallic membrane

Modular transmitter

Long term stability

Enhanced safety via self diagnostic functions

Secondary process barrier

Specialities

diagnostic functionalities

different languages in software

Supply / Communication

4...20mA HART:

10,5...45V DC

Ex ia: 10,5...30V DC

PROFIBUS PA /

FOUNDATION Fieldbus:

9...32V DC

 Accuracy  Standard: 0.05%

Platinum: up to 0.025%

 Long term stability  0,05% of URL/year
 Ambient temperature  -50°C...85°C

(-58°F...185°F)

 Process temperature  -40°C...125°C

(-40°F...257°F)

 Process pressure / max. overpressure limit 1050bar (15,750psi)
 Pressure measuring range 400 mbar...700 bar

(5.8 psi...10.500 psi)

 Main wetted parts  Alloy C276

316L

Rhodium

 Process connection  Threads

Flanges (DIN, ASME, ...) with flush membrane

 Max. measurement distance  7000m (22.966ft) H2O
 Communication  4...20 mA HART

1- 5V DC Low Power

PROFIBUS PA

FOUNDATION Fieldbus

 Certificates / Approvals  ATEX, FM, CSA, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC
 Safety approvals  SIL
 Design approvals  EN 10204-3.1

NACE MR0175, MR0103

 Marine approval  GL/ ABS
 Drinking water approvals  NSF
 Options HistoROM/M-Dat

4-line digital display

SS- or Aluminiumhousing

Separate housing

 Successor  PMP71B
 Application limits  Measuring cell: Metal

welded

If pressurized, possibly

use differential pressure

meas-urement with two

pressure transmitters

(electronic dp). Observe