Endress+Hauser
Absolute and gauge pressure Cerabar PMP75 series
- SKU:
- Absolute and gauge pressure Cerabar PMP75 series
- Weight:
- 0.00 Grams
Description
Application
The Cerabar PMP75 is a digital pressure transmitter equipped with a metal diaphragm seal, designed primarily for process and hygiene applications involving the measurement of pressure, level, volume, or mass in liquids or gases. It is particularly well-suited for high-pressure environments and extreme process temperatures, ranging from -70°C to +400°C (-94°F to 750°F). The device offers a Quick Setup feature with an adjustable measuring range, streamlining the commissioning process, reducing costs, and saving time. Built in accordance with IEC 61508 standards, the Cerabar PMP75 is suitable for use in SIL2/3 safety applications.
The transmitter is available with a dual-chamber housing made of either aluminum or stainless steel (316L).
Process connections: Options include threads, flanges, or hygienic connections.
Process temperature range: -70°C to +400°C (-94°F to 752°F).
Pressure range: -1/0 up to 400 bar (-15/0 up to +6,000 psi).
Accuracy: ±0.075%.
The Cerabar PMP75 comes with international certifications for explosion protection, overfill prevention (WHG), SIL compliance, hygienic approvals, and marine approvals.
Benefits
- Wide selection of process connections and diaphragm materials to suit various applications.
- The innovative TempC Membrane reduces the impact of ambient and process temperature fluctuations.
- The HistoROM data management system enables quick and easy commissioning, maintenance, and diagnostics.
- User-friendly menu-driven setup via local display, with options for 4 to 20mA HART, PROFIBUS PA, or FOUNDATION Fieldbus communication.
- Enhanced safety with gas-tight feedthroughs, supporting SIL2/3 applications and certified to IEC 61508 standards.
- Cost efficiency through a modular design that allows easy replacement of sensors, displays, or electronics.
- The system is resistant to overload and continuously monitored from the sensor to the electronics.
SPECIFICATIONS
Pressure Specifications
Measuring principle | Absolute and gauge pressure |
Characteristic |
Digital transmitter with piezoresistive sensor and diaphragm seal Modular transmitter Long term stability Minimum oil volume process connection Enhanced safety via self diagnostic functions Secondary process barrier |
Supply voltage | 4...20 mA HART
10,5...45V DC (Non Ex): Ex ia: 10,5...30V DC PROFIBUS PA: 9...32 V DC (Non Ex) FOUNDATION Fieldbus: 9...32 V DC (Non Ex) |
Reference Accuracy | 0,075% + influence of diaphragm seal |
Long term stability | 0.05 % of URL/ year
0.07 % of URL/ 5 years 0.1 % of URL/ 10 years |
Process temperature | -70°C...400°C
(-94°F...752°F) |
Ambient temperature | -50°C...85°C
(-58°F...185°F) |
Measuring cell | 400 mbar...400 bar
(5.8 psi...6000 psi) relative/ absolute |
Smallest calibratable span | 5 mbar (0.075 psi) |
Vacuum resistance | 10 mbar (0.15 psi) |
Max. Turn down | 100:1 |
Max. overpressure limit | 1050 bar (15.750 psi) |
Process connection | Thread:
G1/2...G2, R1/2, MNPT1/2...MNPT2, NPT1/2...NPT1 Flange: DN25...DN100, ASME 1"...4", JIS 10K Diaphragm seal |
Process connection hygienic | Tri-Clamp
DIN11851 NEUMO Varivent SMS DRD Universal adapter |
Material process membrane | 316L, AlloyC,
Tantal Rhodium> Gold PTFE |
Material gasket | None, diaphragm welded |
Fill fluid | Silicone oil,
Inert oil, Vegetable oil, High temperature oil, Low temperature oil, |
Material housing | Die-cast aluminum,
AISI 316L |
Communication | 4...20 mA HART
PROFIBUS PA FOUNDATION Fieldbus |
Certificates / Approvals | ATEX, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC |
Safety approvals | SIL |
Design approvals | EN10204-3.1
NACE MR0103 |
Hygienic approvals | 3A, EHEDG |
Marine approvals | GL/ ABS |
Specialities | Diagnostic functions
TempC Membrane |
Successor | PMP71B |
Continuous / Liquids Specifications
Measuring principle | Absolute and gauge pressure |
Characteristic / Application |
Digital transmitter with piezoresistive sensor and diaphragm seal Modular transmitter Long term stability Minimum oil volume Enhanced safety via self diagnostic functions Secondary process barrier |
Specialities |
Diagnostic functionalities Different languages in software |
Supply / Communication |
4...20mA HART: 10,5...45V DC Ex ia: 10,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC |
Accuracy | 0,075% + influence of diaphragm seal |
Long term stability | 0,05% of URL/year |
Ambient temperature |
-50°C...85°C (-58°F...185°F) |
Process temperature |
-70°C...400°C (-94°F...752°F) |
Process pressure / max. overpressure limit |
1050bar (15,200psi) |
Pressure measuring range |
400 mbar...400 bar (5.8 psi...6000 psi) |
Main wetted parts |
Alloy C276 316L Monel Tantalum PTFE-Foil |
Process connection |
Threads Flanges (DIN, ASME, JIS) with flush membrane Tri-Clamp ISO02852 Hygienic connections |
Max. measurement distance | 7000m (22.966ft) H2O |
Communication |
4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus |
Certificates / Approvals | ATEX, FM, CSA, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC |
Safety approvals |
SIL |
Design approvals |
EN 10204-3.1 NACE MR0175, MR0103 |
Hygienic approvals | 3A, EHEDG |
Marine approval |
GL/ ABS |
Options |
HistoROM/M-Dat 4-line digital display SS- or Aluminiumhousing Separate housing |
Successor |
PMP71B |
Application limits |
Measuring cell: Metal welded If pressurized, possibly use differential pressure meas-urement with two pressure transmitters (electronic dp). Observe ratio head pressure : hydrostatic pressure |
Documents
You may want to read this product's catalog. If so, please click to view the Endress+Hauser Absolute and gauge pressure Cerabar PMP75 Series datasheet.