Description

Application


The Cerabar PMC51 digital pressure transmitter, equipped with a capacitive, oil-free ceramic sensing cell, is ideal for use in both process and hygienic applications, providing accurate pressure, level, volume, or mass measurements in liquids and gases. Its vacuum-resistant ceramic membrane, featuring integrated breakage detection, ensures a high level of system safety. The Quick Setup function with an adjustable measuring range facilitates easy commissioning, saving both time and costs. This device is SIL2 certified according to IEC 61508 / IEC 61511.

The transmitter is available with a single chamber housing made of either aluminum or stainless steel (316L).

Process Connections: Available with threaded, flanged, or hygienic connections.
Process Temperature: Ranges from -40 to +130°C (-40 to +266°F), with a capability of 150°C (302°F) for up to 1 hour.
Measuring Ranges: From -1/0 up to +40 bar (-15/0 to +600 psi).
Accuracy: ±0.1%, or "Platinum" ±0.075%.
Certifications: International explosion protection certificates, SIL, hygienic approvals, marine approvals.

 

 


 

 

Benefits

  • Optimal for vacuum applications and those involving corrosive or abrasive media.
  • Ensures process safety with membrane breakage detection.
  • Features an overload-resistant, high-purity ceramic sensor (99.9% Al2O3).
  • Condensation-resistant, making it suitable for hygienic applications.
  • Simplifies commissioning with an easy-to-navigate menu via the local display; supports 4 to 20mA with HART, PROFIBUS PA, and FOUNDATION Fieldbus.
  • Certified for process pressure up to SIL2, in accordance with IEC 61508 and IEC 61511.
  • Available with pre-assembled manifolds: always a perfect fit, always tested for leaks.

SPECIFICATIONS

Pressure Specifications

Measuring principle Absolute and gauge pressure
Characteristic

Smart and reliable pressure transmitter with capacitive measuring cell and ceramic process isolating diaphragm Ceraphire)

Supply voltage

 

4...20 mA HART

11,5...45V DC (Non Ex):

Ex ia: 11,5...30V DC

PROFIBUS PA:

9...32 V DC (Non Ex)

FOUNDATION Fieldbus:

9...32 V DC (Non Ex)

Reference Accuracy

Standard 0.1%

Platinum 0.075%

Long term stability

0.2% of URL/ year

0.4% of URL/ 5 years

0.5% of URL/ 10 years

Process temperature

-40°C...+130°C

(-40°F...+266°F

+150°C for 1h

(+302°F for 1h)

Ambient temperature

 

-40°C...+85°C

(-40°F...+185°F)

Measuring cell

100 mbar...40 bar

(1.5 psi...600 psi)

relative/ absolute

Smallest calibratable span

10 mbar (0.15 psi)

Vacuum resistance

0 mbar abs.

Max. Turn down

20:1

Max. overpressure limit

60 bar (900 psi)
Process connection

Thread:

G1/2...G2, R1/2, MNPT1/2

Flange:

DN25...DN80,

ASME 1"...4",

JIS 10K

Process connection hygienic

Tri-Clamp

DIN11851

DIN11864-1

NEUMO

Varivent N

SMS

DRD

Material process membrane Ceramic
Material gasket Viton, EPDM, NBR, Kalrez
Fill fluid None, dry measuring cell
Material housing

Die-cast aluminum,

AISI 316L

Communication

4...20 mA

4...20 mA HART

PROFIBUS PA

FOUNDATION Fieldbus

IO-Link

 Certificates / Approvals  ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex
 Safety approvals

SIL

 Design approvals  EN10204-3.1

NACE MR0175

 Hygienic approvals  CoC ASME-BPE

3A, EHEDG

 Marine approvals  GL/ ABS/ LR/ BV/ DNV
 Drinking water approvals

NSF

 Successor  PMC51B

 

Continuous / Liquids Specifications

Measuring principle Absolute and gauge pressure
Characteristic / Application

Smart and reliable pressure transmitter, with capacitive measuring cell and

ceramic process isolating diaphragm

(Ceraphire)

Supply / Communication

4 ..20 mA HART:

11,5...45V DC

Ex ia: 11,5...30V DC

PROFIBUS PA

FOUNDATION Fieldbus

Accuracy

Standard 0.1%

Platinum 0.075%

Long term stability

< 0,1% of URL/ year

< 0,25% of URL/ 5 years

< 0,4% of URL/ 10 years

Ambient temperature

-40°C...85°C

(-40°F...185°F)

Process temperature

-20°C...130°C

(-4°F...266°F)

Process pressure / max. overpressure limit 60 bar (900 psi)
Pressure measuring range

100 mbar...40 bar

(1.5psi...600psi)

Main wetted parts

Ceraphire

Sealing

Alloy C276

316L

Process connection

Threads

Flanges (DIN, ASME, JIS)

Max. measurement distance 400 m (1312 ft) H2O
Communication

4...20 mA HART

PROFIBUS PA

FOUNDATION Fieldbus

IO-Link

Certificates / Approvals ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI
Safety approvals SIL
Design approvals

EN 10204-3.1

NACE MR0175, MR0103

Hygienic approvals

3A, EHEDG

CoC ASME-BPE

Marine approval

GL/ ABS/ LR/ BV/ DNV
Drinking water approvals NSF
Options Local display
Successor PMC51B
Application limits

Measuring cell: ceramics

If pressurized, possibly use differential pressure measurement with two pressure transmitters (electronic dp). Observe ratio head pressure : hydrostatic pressure

 

 

Documents

You may want to read this product's catalog. If so, please click to view the Endress+Hauser Absolute and gauge pressureCerabar PMC51 Series datasheet.
View AllClose