null
Endress+Hauser

Absolute and gauge pressureCerabar PMC71 series

(No reviews yet) Write a Review
SKU:
Absolute and gauge pressureCerabar PMC71 series
Weight:
0.00 Grams
Call us: +971 4 259 5133

Description

Application


The Cerabar PMC71 is a digital pressure transmitter featuring a capacitive, oil-free ceramic measuring cell, designed for use in both process and hygienic applications. It is ideal for measuring pressure, level, volume, or mass in liquids and gases. The device ensures a high level of system safety, equipped with a vacuum-proof ceramic membrane and integrated breakage detection. The Quick Setup function with an adjustable measuring range facilitates simple commissioning, reducing both costs and time. It is also SIL2/3 compliant according to IEC 61508 standards.

The transmitter is available with a two-chamber housing made of aluminum or stainless steel (316L).

Key Specifications:

  • Process connections: Available in threaded, flanged, or hygienic designs

  • Process temperature range: -40 to +150°C (-40 to +302°F)

  • Measuring ranges: From -1/0 up to +40 bar (+1.5 to +600 psi)

  • Accuracy: ±0.05%, with "Platinum" option offering ±0.025%

  • International certifications: Explosion protection, overfill prevention (WHG), SIL, hygienic, marine approvals 

 


 

Benefits

  • Optimal for vacuum applications and environments with corrosive or abrasive media.
  • Enhanced process safety through membrane breakage detection.
  • Equipped with an overload-resistant, high-purity ceramic sensor (99.9% Al2O3).
  • Features the HistoROM data management concept for quick and easy commissioning, maintenance, and diagnostics.
  • Supports straightforward menu-driven commissioning via a local display, with 4 to 20mA HART, PROFIBUS PA, and FOUNDATION Fieldbus communication options.
  • Ensures maximum safety with a gastight feedthrough, supporting SIL2/3 compliance and certified to IEC 61508.
  • Available with pre-mounted manifolds, ensuring a perfect fit and leak-tested integrity.

SPECIFICATIONS

Pressure Specifications

Measuring principle Absolute and gauge pressure
Characteristic

Digital transmitter with capacitive sensor and ceramic membrane

Modular transmitter

Long term stability

Enhanced safety via self diagnostic functions

Secondary process barrier

Supply voltage

4...20 mA HART

10,5...45V DC (Non Ex):

Ex ia: 10,5...30V DC

PROFIBUS PA:

9...32 V DC (Non Ex)

FOUNDATION Fieldbus:

9...32 V DC (Non Ex)

Reference Accuracy

Standard: 0.05%

Platinum: up to 0.025%

 

Long term stability

0.05 % of URL/ year

0.08 % of URL/ 5 years

0.1 % of URL/ 10 years

Process temperature

-20°C...150°C

(-4°F...257°F)

Ambient temperature

-40°C...85°C

(-40°F...185°F)

Measuring cell

100 mbar...40 bar

(1.5 psi...600 psi)

relative/ absolute

Smallest calibratable span

5 mbar (0.075 psi)

Vacuum resistance 0 mbar abs.
Max. Turn down 100:1
Max. overpressure limit 60 bar (900 psi)
Process connection

Thread:

G1/2...G2, R1/2, MNPT1/2...MNPT2

Flange:

DN25...DN80,

ASME 1"...4",

JIS 10K

Process connection hygienic

Tri-Clamp

DIN11851

Varivent N

SMS

DRD

Material process membrane Ceramic
Material gasket

Viton, EPDM, Chemraz, Kalrez, NBR

Fill fluid

none, dry measuring cell

Material housing

Die-cast aluminum,

AISI 316L

Communication

4...20 mA HART

PROFIBUS PA

FOUNDATION Fieldbus

Certificates / Approvals

ATEX, FM, CSA, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC, UK Ex

Design approvals

EN10204-3.1

Hygienic approvals

3A, EHEDG

Marine approvals

GL/ ABS

Drinking water approvals NSF
Specialities Diagnostic functions
Successor

PMC71B

 

Continuous / Liquids Specifications

 

Measuring principle Absolute and gauge pressure
Characteristic / Application

Digital transmitter with capacitive sensor and ceramic membrane

Modular transmitter

Long term stability

Enhanced safety via self diagnostic functions

Secondary process barrier

 

Specialities

diagnostic functionalities

different languages in software

Supply / Communication

4...20mA HART:

10,5...45V DC

Ex ia: 10,5...30V DC

PROFIBUS PA /

FOUNDATION Fieldbus:

9...32V DC

Accuracy

Standard: 0.05%

Platinum: up to 0.025%

Long term stability

0,05% of URL/year

Ambient temperature

-40°C...85°C

(-40°F...185°F)

Process temperature

-40°C...150°C

(-40°F...302°F)

Process pressure / max. overpressure limit

60bar (900psi)

Pressure measuring range

100mbar...40bar

(1.5psi...600psi)

Main wetted parts

Ceraphire ceramic

Alloy C

316L

Monel

PVDF

Process connection

Threads

Flanges

Tri-Clamp ISO2852

Hygienic connections

Max. measurement distance 400m (1312ft) H2O
Communication

4 ... 20 mA HART

PROFIBUS PA

FOUNDATION Fieldbus

Certificates / Approvals

ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC

Design approvals EN 10204-3.1

Marine approval

GL/ ABS
Drinking water approvals

NSF

Options

HistoROM/M-Dat

4-line digital display

SS- or Aluminiumhousing

Separate housing

Successor PMC71B
Application limits

Measuring cell: ceramics

If pressurized, possibly

use differential pressure

measurement with two

pressure transmitters

(electronic dp). Observe

ratio head pressure :

hydrostatic pressure

 

Documents

You may want to read this product's catalog. If so, please click to view the Endress+Hauser Absolute and gauge pressureCerabar PMC71 Series datasheet.
View AllClose