Autonics
Digital Panel Meter, Various Input Mode - MP5W-4N
- SKU:
- MP5W-4N
- MPN:
- MP5W-4N
- Weight:
- 400.00 Grams
- Minimum Purchase:
- 1 unit
Description
Autonics Multi Pulse Meters - MP5W-4N
5-digit 7-segment LED, -1999 to 9999 display Range, Indicator
As a quick report, this panel meter provides:
- Display method: 5-digit 7-segment LED
- Character height: 14 mm
- Max. display Range: -19999 to 99999
- 16 operation modes: Frequency, Revolutions, Speed, Cycle, Time, Ratio, Density, Error, Length measurement, Interval, Accumulation, Addition/Subtraction, etc.
- Measurement range: 0.0005Hz to 50kHz, 0.01 to max. of each time range, 0 to 99999, -19999 to 99999
- Input method: Voltage input (PNP), No-voltage input (NPN)
- Power supply: 100-240 VAC ~ 50/60 Hz
- External Power Supply: Max. 12 VDC ±10% 80 mA
- Output_Main Output (Comparative Value): Indicator
Temperature
There are limitations in temperature and humidity in which MP5W-4N panel meter is used:
- Storage temperature: -20 … 60°C
- Storage humidity: 35 to 85%RH
- Ambient temperature: -10 … 50°C
- Ambient humidity: 35 to 85%RH
Environment resistance is rated at no freezing or condensation.
Industries / applications
- Rubber Extrusion / Plastic Injection Molding Process
- Frame Assembly: measure the movement speed of car frames on conveyor belts during assembly process.
Click on the following link to view other Autonics Digital Panel Meter series.
Series Information
MP5S/MP5Y/MP5W Series
High Performance Digital Pulse Meters
The Autonics MP5S/MP5Y/MP5W series high performance digital pulse meters can display various values using pulse inputs including rotation speed, speed, frequency, and more with 16 different operation modes. The meters can be applied in various industrial applications for accurate measurement and clear readings.
*Select features of the MP5S/MP5Y/MP5W series have been upgraded. Please refer to the specifications table for upgrade details.
MP5S/MP5Y/MP5W Series Main features
- 16 operation modes
- Various output options
- Relay triple / quintuple output, NPN / PNP open collector quintuple output, BCD dynamic output, PV transmission output (current output), RS485 communication output
- Various functions
- Prescale function, delay monitoring function, hysteresis, auto-zero, parameter lock function, data bank function (MP5W only)
- NPN input (non-contact / contact) or PNP input (non-contact / contact)
- Display range: -19999 to 99999
- Various display units
- rpm, rps, Hz, kHz, sec, min, m, mm, mm/s, m/s, m/min, m/h, â„“/s, â„“/min, â„“/h, %, counts, etc.
- Power supply
- 100-240VAC 50/60Hz (AC type)
- 24VAC 50/60Hz, 24-48VDC (AC/DC type)
About Autonics Digital Panel Meter
"Autonics" is a leading provider of automation solutions from South Korea. Autonics products are trusted and adopted by engineers in various industrial applications and their technology is widely applied in day-to-day automation devices. This company represents 17 Digital Panel Meter:
- MX4W Series: LCD Display Multi Panel Meter
- M4V Series: Digital Panel Meters for Mosaic Panels
- M4N Series: Compact Digital Panel Meters
- M4NN Series: Compact Digital Panel Meters with Diverse Input Options
- MT4Y/MT4W Series: Digital Panel Meters with Diverse Input/Output Options
- MT4N Series: Compact Digital Panel Meters with Diverse Input/Output Options
- M4NS/M4YS Series: Loop-Powered Digital Scaling Meters
- M4Y, M5W, M4W, M4M (Scaling) Series: Digital Scaling Meter
- M4Y, M5W, M4W, M4M (Voltmeter) Series: Digital Voltmeters
- M4Y, M5W, M4W, M4M (Wattmeter) Series: Digital Wattmeters
- M4Y, M5W, M4W, M4M (Ammeter) Series: Digital Ammeters
- MP5S/MP5Y/MP5W Series: High Performance Digital Pulse Meters
- MP5M Series: High Performance Digital Pulse Meters (Thumbwheel Switch Type)
- M4W-P Series: Power Factor Display Digital Panel Meters
- LR5N-B Series: Compact Digital Pulse Meters (Indicator Only)
- M4Y, M5W, M4W, M4M (Tachometer / Speed Meter) Series: Digital Tachometers (Speed Meters)
Autonics Digital Panel Meter are mainly used in:
- Measure and display voltage and current of processes on LCD inspection machines
- Plastics/Rubber Industry
- Logistics Industry
- Measure and display voltage and current of processes on distribution panels
- Automotive
Documents
You may be interested to see this product's catalog. If so, please click to view the MP5W-4N datasheet.Additional Information
Display method: |
7 segment LED (zero blanking method). |
Digit size: |
W 7 x H 14mm. |
Display range: |
-19999~99999. |
Power supply: |
AC voltage 100-240VAC (50/60 Hz). |
Power supply: |
AC/DC voltage 24VAC (50/60Hz), 24-48VDC. |
Power consumption: |
AC voltage Max. 15 VA. (100-240VAC 50/60Hz). |
Power consumption: |
AC/DC voltage Max. 11 VA (24VAC 50/60Hz). Max. 7W (24-48VDC). |
Permissible voltage range: |
90~110% of rated voltage. |
External power supply: |
Max. 12VDC ±10% 80mA. |
Sub-power supply: |
Max. 24VDC 30mA |
Input freq.: |
Solid-state input 1: max 50KHz (pulse width: min 10µs). Solid-state input 2: max 5KHz (pulse width: min 100µs). For F7, F8, F9, F10 operation mode, max 1 KHz (pulse width min 500µs). Contact input max. 45Hz (pulse width: min 11ms). |
Input method: |
[Voltage input] High: 4.5-24VDC, Low: 0-1VDC. Input impedance: 3.9KΩ. [no voltage input] Short circuit impedance: Max. 80Ω. Residual voltage: Max 1VDC. Open circuit impedance: Min. 100KΩ. |
Measurement range: |
Operation mode F1, F2, F7, F8, F9, F10: 0.0005Hz to 50kHz. Operation mode F3, F4, F5, F6: 0.01 to each of max. range. Operation mode F11,F12, F13, F16: 0 to 99999. Operation mode F14, F15: -19999 to 99999. |
Measurement accuracy (23◦C±5◦C): |
Operation mode F1, F2, F7, F8, F9, F10: FS±0.05%rdg±1-digit. Operation mode F3, F4, F5, F6: FS±0.01%rdg±1-digit. |
Display cycle: |
OFF (for F2, F16 operation mode), 0.05, 0.5, 1, 2, 4, 8 sec (same as update output cycle). |
Operation mode: |
Frequency/revolution/speed (F1), Passing speed (F2), Cycle (F3), Passing time (F4), Time interval (F5), Time differential (F6), Absolute ratio (F7), Error ratio (F8), Density (F9), Error (F10), Length measurement 1 (F11), interval (F12), Accumulation |
Pre-scale function: |
Direct input method (0.0001x10-9 to 9.9999x109). |
Hysteresis: |
0-9999x1. |
output: |
Main Relay triple 250VAC, 3A. 30VDC, 3A resistive load. |
output: |
Main Relay quintuple 250VAC, 3A. 30VDC, 3A resistive load. |
output: |
Main NPN/PNP open collector quintuple Max. 30VDC, 30mA. |
output: |
Sub BCD dynamic Max. 30VDC, 30mA. |
output: |
Sub PV transmission DC4-20mA/DC0-20mA max load 500Ω. |
output: |
Sub Communication RS-485 communication output (Modbus RTU method). |
Memory retention: |
Non-volatile memory (no. of inputs 100,000 operations). |
Insulation resistance: |
100MΩ (at 500VDC megger). |
Dielectric strength: |
2000VAC 50/60Hz for 1 min. |
Noise immunity: |
±2KV the square wave noise (pulse width 1µs) by the noise simulator. |
Vibration: |
Mechanical 0.75mm Amp. at freq. 0f 10-55Hz (for 1min.) in each X, Y, Z directions for 1 hour. |
Vibration: |
Malfunction 0.5mm Amp. at freq. 0f 10-55Hz (for 1min.) in each X, Y, Z directions for 10 min. |
Shock: |
Mechanical 300m/s2 (approx. 30G) in each X, Y, Z directions for 3 times. |
Shock: |
Malfunction 100m/s2 (approx. 10G) in each X, Y, Z directions for 3 times. |
Relay life cycle: |
Mechanical Min. 10,000,000 operations. |
Relay life cycle: |
Electrical Min. 100,000 operations (250VAC 3A resistive load). |
Environment: |
Ambient temp. -10~55â—¦C, storage -20~60â—¦C. |
Environment: |
Ambient humidity 35-85% HR, storage: 35-85% HR. |
Approval: |
CE. |
Unit weight: |
Approx. 334g. |