Endress+Hauser
Cerabar PMC51B - pressure transmitter
- SKU:
- Cerabar PMC51B - pressure transmitter series
- Weight:
- 0.00 Grams
Description
Application
The Cerabar PMC51B pressure transmitter is part of the latest generation of Cerabar devices, offering a blend of durability and advanced features. It provides straightforward local or remote operation and supports condition-based maintenance. The software is designed for user-friendliness, featuring intuitive wizards that guide users through commissioning and proof testing, significantly reducing the risk of operational errors. Additionally, the transmitter can be controlled remotely via a mobile app using a secure Bluetooth connection.
- Pressure measuring range: up to 40 bar (600 psi)
- Vacuum resistance: fully resistant up to +100°C (212°F) process temperature
- Accuracy: up to +/-0.055%
Benefits
- Wireless device control in the process area using the SmartBlue App, eliminating the need for process interruption.
- Minimizes systematic failures with error-free SIL commissioning and guided proof testing.
- Enhances safety by reducing on-site accidents and protecting equipment in hard-to-reach areas.
SPECIFICATIONS
Pressure Specifications
Measuring principle
|
Absolute and gauge pressure
|
Characteristic |
Pressure transmitter with ceramic process membran for accurate measurement in liquid or gases. Intuitive and clear wizard for commissioning
|
Supply voltage
|
Ex d, Ex e, non-Ex: 10.5...35V DC Ex i: 10.5...30V DC
|
Reference Accuracy
|
Standard: up to 0.075 % Platinum: up to 0.055 %
|
Long term stability
|
0.10% of URL/ year 0.25% of URL/ 5 years 0.40% of URL/ 10 years
|
Process temperature
|
-40°C...+100°C (-40°F...+212°F)
|
Ambient temperature
|
-40°C...+85°C (-40°F...+185°F)
|
Measuring cell
|
100 mbar...40 bar (1.5 psi...600 psi)
|
Smallest calibratable span
|
5 mbar (0.075 psi)
|
Vacuum resistance
|
0 mbar abs.
|
Max. Turn down
|
100:1
|
Max. overpressure limit
|
60 bar (900 psi)
|
Process connection
|
Thread: G1/2...G2, R1/2, MNPT1/2...MNPT2, FNPT1/2 Flange: DN25...DN80, NPS 1"...4"
|
Material process membrane
|
Ceramic
|
Material gasket
|
FKM, EPDM, HNBR, FFKM
|
Fill fluid
|
none, dry measuring cell
|
Material housing
|
Aluminium
|
Communication
|
4...20 mA, 4...20 mA HART PROFINET with Ethernet-APL Bluetooth® wireless technology and app (optional)
|
Certificates / Approvals
|
ATEX, CSA, IECEx, JPN Ex, INMETRO, NEPSI, UK Ex
|
Safety approvals
|
SIL
|
Design approvals
|
EN10204-3.1 NACE MR0175, NACE MR0103
|
Drinking water approvals
|
NSF, KTW
|
Specialities
|
Bluetooth® Operation and maintenance SmartBlue App, RFID TAG for easy identification, Plug and play functionalities
|
Continuous / Liquids Specifications
Measuring principle
|
Absolute and gauge pressure
|
Characteristic / Application
|
Pressure transmitter with ceramic process membran for accurate measurement in liquid or gases. Intuitive and clear wizard for commissioning
|
Specialities
|
Bluetooth® Operation and maintenance SmartBlue App, RFID TAG for easy identification, Plug and play functionalities
|
Supply / Communication
|
Ex d, Ex e, non-Ex:: 10.5...35V DC Ex i: 10.5...30V DC
|
Accuracy |
Standard: up to 0.075 % Platinum: up to 0.055 %
|
Long term stability
|
0.10 % of URL/ year 0.25 % of URL/ 5 years 0.40 % of URL/ 10 years
|
Ambient temperature
|
-40°C...+85°C (-40°F...+185°F)
|
Process temperature
|
-40°C...+100°C (-40°F...+212°F)
|
Process pressure / max. overpressure limit
|
40 bar (600 psi)
|
Pressure measuring range
|
100 mbar...40 bar (1.5 psi...600 psi)
|
Main wetted parts
|
Ceraphire ceramic FKM, EPDM, HNBR, Perlast, Kalrez
|
Process connection
|
Thread: G1/2...G2, R1/2, MNPT1/2...MNPT2, FNPT1/2 Flange: DN25...DN80, NPS 1"...4"
|
Max. measurement distance
|
400 m (1312 ft) H2O |
Communication
|
4...20 mA, 4...20 mA HART PROFINET with Ethernet-APL Bluetooth® wireless technology and app (optional)
|
Certificates / Approvals
|
ATEX, IEC Ex, CSA C/US, NEPSI
|
Safety approvals
|
SIL |
Design approvals
|
EN 10204-3.1 NACE MR0175, NACE MR0103
|
Drinking water approvals
|
NSF, KTW
|
Application limits
|
Measuring cell: ceramics If pressurized, possibly use differential pressure measurement with two pressure transmitters (electronic dp). Observe ratio head pressure : hydrostatic pressure
|
Documents
You may want to read this product's catalog. If so, please click to view the Endress+Hauser Cerabar PMC51B - pressure transmitter series datasheet.