Application

The Prosonic Flow E Heat is an ideal heat flow sensor for optimizing energy management across various industries. It is equipped with recognized approvals for custody transfer in heating and cooling applications, making it suitable for flexible industrial use. Its measuring principle is independent of pressure, density, temperature, and conductivity, ensuring reliable performance. This device is the optimal choice for managing energy in water-related applications, such as heating and cooling, across all sectors. Device Features:

  • Accuracy Class 2, adhering to international standards such as MI-004, EN 1434, OIML R75
  • Full stainless steel sensor housing
  • Operates at process temperatures up to 150 °C (302 °F)
  • Certified pulse output for accurate readings
  • Cost-effective transmitter designed for specific applications

Benefits

  • Full compliance with custody transfer regulations
  • Long-term stability with a durable, industrial-grade sensor
  • Energy and cost efficiency with an optimized sensor for fully insulated pipes
  • Dependable flow measurement with a high turndown ratio
  • Easy and safe operation without commissioning, with locked pulse output preventing unauthorized access
  • Clear process indication with direct status information displayed through color LEDs
  • Enhanced reliability with comprehensive diagnostic features

SPECIFICATIONS


Liquids Specifications

 

Measuring principle

 

 

 

Ultrasonic flow

 

 

Product headline

 

 

Industrial, certified heat flow sensor for improved energy consumption measurement.

Full compliance with custody transfer regulations.

Best choice for energy management of water (e.g. heating and cooling) across all industries.

 

 

Sensor features

 

 

Long-term stability – reliable sensor with robust industrial design. Energy and cost savings – optimized sensor for fully insulated pipes. Dependable flow measurement – high turndown.

Accuracy Class 2 according to international approvals such as MI-004, EN 1434, OIML R75. Entire sensor housing made of stainless steel. Process temperatures up to 150 °C (302 °F).

 

 

Transmitter features

 

 

Effortless, safe operation – no commissioning needed, no unauthorized device access due to locked pulse output. Simple process indication – direct reading of status information via color LEDs. Increased reliability – comprehensive diagnostics.

Certified pulse output. Cost-efficient, application-optimized transmitter.

 

 

Nominal diameter range

 

 

DN 50 to 150 (2"to 6")

 

 

Wetted materials

 

 

Measuring tube: 1.4301 (F304)

Process Connection: 1.4571; 1.4404 (F316L); 1.0038 (S235JR); 1,4306 (F304L); 1.4307 (F304L); A105

 

 

Measured variables

 

 

Flow velocity, sound velocity

 

 

Max. measurement error

 

 

MID 004 accuracy class II (2%)

 

 

Measuring range

 

 

0.025 to 5 m/s (0.02 to 16.4 ft/s)

0 to 6360 dm3/min (0 to 1680 gal/min)

 

 

Max. process pressure

 

 

PN 25/ ASME Cl. 150

 

 

Medium temperature range

 

 

0 to 150° (17.8 to 302 °F)

 

 Ambient temperature range  

-20 to 60 °C (-4 to 140 °F)

 

 

Sensor housing material

 

 

Stainless steel

 

Transmitter housing material

 

Compact: AlSi10Mg, coated

 

 Degree of protection  

Standard: IP66/67, Type 4X enclosure

With opened housing: IP20, Type 1 enclosure

 

 

Display/Operation

 

 

direct reading of status information via color LEDs

 

 

Outputs

 

 

Pulse/Frequency

 

Inputs

 

None

 

Digital communication

 

None

 

Power supply

 

 

DC 19.2 to 28.8 V

 

Hazardous area approvals

 

 

None

 

 

Product safety

 

 

CE, C-Tick, EAC marking

 

Metrological approvals and certificates

 

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)

 

Pressure approvals and certificates

 

 

PED

 

 

Material certificates

 

 

3.1 material

 

 