Endress+Hauser
Chemically Resistant Coriolis Flowmeter Proline Promass H 100
- SKU:
- Proline Promass H 100 Series
- MPN:
- Proline Promass H 100
- Weight:
- 0.00 Grams
Description
Application
The Promass H, with its chemically resistant single-tube design, is specifically suited for applications requiring high corrosion resistance. Its compact transmitter housing, one of the smallest available, ensures maximum performance in a minimal space. This makes the Promass H 100 an ideal choice for system integrators, skid builders, and equipment manufacturers where space is limited. The measuring principle operates independently of fluid properties such as viscosity or density, ensuring highly accurate measurement of liquids and gases in environments that demand maximum corrosion resistance. Device Properties:
- Measuring tube material: Tantalum, Zirconium
- Nominal diameters: DN 8 to 50 (3/8 to 2")
- Medium temperature range: up to +205°C (+401°F)
- Ultra-compact and robust transmitter housing
- High ingress protection: IP69K
- Optional local display available
Benefits
- Ensures maximum safety when handling chemically aggressive fluids due to corrosion-resistant wetted parts.
- Reduces the need for multiple process measuring points with multivariable measurement capabilities (flow, density, temperature).
- Saves space during installation, as there are no requirements for in/outlet runs.
- Compact transmitter offers full functionality in the smallest possible footprint.
- Streamlines local operation with an integrated web server, eliminating the need for additional software or hardware.
- Features Heartbeat Technology for integrated verification, enhancing system reliability.
Documents
You may want to read this product's catalog. If so, please click to view the Proline Promass H 100 Series datasheet.SPECIFICATIONS
Liquids Specifications
Measuring principle | Coriolis |
Product headline | Chemically resistant single-tube flowmeter with an ultra-compact transmitter. Measuring highly accurately liquids and gases in applications requiring highest corrosion resistance. |
Sensor features | Maximum safety for chemically aggressive fluids – corrosion-resistant wetted parts. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space-saving installation – no in-/outlet run needs. Measuring tube made of Tantalum, Zirconium. Nominal diameter: DN 8 to 50 (³⁄₈ to 2"). Medium temperature up to +205 °C (+401 °F). |
Transmitter features | Space-saving transmitter – full functionality on the smallest footprint. Time-saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology. Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available. |
Nominal diameter range | DN 8 to 50 (³⁄₈ to 2") |
Wetted materials | Measuring tube: Tantalum 2.5W; 702 (UNS R60702). Connection: Tantalum; 702 (UNS R60702) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.1 %. Volume flow (liquid): ±0.1 %. Mass flow (gas, Tantalum only): ±0.5 %. Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 70 000 kg/h (0 to 2570 lb/min) |
Max. process pressure | PN 40, Class 300, 20K |
Medium temperature range | Tantalum: –50 to +150 °C (–58 to +302 °F). Zirconium: –50 to +205 °C (–58 to +401 °F) |
Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F). Option: –50 to +60 °C (–58 to +140 °F) |
Sensor housing material | 1.4301 (304), corrosion resistant |
Transmitter housing material | Compact: AlSi10Mg, coated. Compact/ultra-compact: 1.4301 (304) |
Degree of protection | Standard: IP66/67, type 4X enclosure. Option: IP69 |
Display/Operation | 4-line backlit display available (no local operation). Configuration via web browser and operating tools possible |
Outputs | 4-20 mA HART (active), Pulse/frequency/switch output (passive) |
Inputs | None |
Digital communication | HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET |
Power supply | DC 20 to 30 V |
Hazardous area approvals | ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC |
Product safety | CE, C-Tick, EAC marking |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025). Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 – Section 7.6a (TÜV SÜD attestation) |
Pressure approvals and certificates | PED, CRN |
Material certificates | 3.1 material |
Gas Specifications
Measuring principle | Coriolis |
Product headline | Chemically resistant single-tube flowmeter with an ultra-compact transmitter. Measuring highly accurately liquids and gases in applications requiring highest corrosion resistance. |
Sensor features | Maximum safety for chemically aggressive fluids – corrosion-resistant wetted parts. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space-saving installation – no in-/outlet run needs. Measuring tube made of Tantalum, Zirconium. Nominal diameter: DN 8 to 50 (³⁄₈ to 2"). Medium temperature up to +205 °C (+401 °F). |
Transmitter features | Space-saving transmitter – full functionality on the smallest footprint. Time-saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology. Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available. |
Nominal diameter range | DN 8 to 50 (³⁄₈ to 2") |
Wetted materials | Measuring tube: Tantalum 2.5W; 702 (UNS R60702). Connection: Tantalum; 702 (UNS R60702) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.1 %. Volume flow (liquid): ±0.1 %. Mass flow (gas, Tantalum only): ±0.5 %. Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 70 000 kg/h (0 to 2570 lb/min) |
Max. process pressure | PN 40, Class 300, 20K |
Medium temperature range | Tantalum: –50 to +150 °C (–58 to +302 °F). Zirconium: –50 to +205 °C (–58 to +401 °F) |
Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F). Option: –50 to +60 °C (–58 to +140 °F) |
Sensor housing material | 1.4301 (304), corrosion resistant |
Transmitter housing material | Compact: AlSi10Mg, coated. Compact/ultra-compact: 1.4301 (304) |
Degree of protection | Standard: IP66/67, type 4X enclosure. Option: IP69 |
Display/Operation | 4-line backlit display available (no local operation). Configuration via web browser and operating tools possible |
Outputs | 4-20 mA HART (active), Pulse/frequency/switch output (passive) |
Inputs | None |
Digital communication | HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET |
Power supply | DC 20 to 30 V |
Hazardous area approvals | ATEX, IECEx, cCSAus, INMETRO, NEPSI |
Product safety | CE, C-Tick, EAC marking |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR. Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 – Section 7.6a (TÜV SÜD attestation) |
Pressure approvals and certificates | PED, CRN |
Material certificates | 3.1 material |
Density/Concentration Specifications
Measuring principle | Coriolis |
Product headline | Chemically resistant single-tube flowmeter with an ultra-compact transmitter. Measuring highly accurately liquids and gases in applications requiring highest corrosion resistance. |
Sensor features | Maximum safety for chemically aggressive fluids – corrosion-resistant wetted parts. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space-saving installation – no in-/outlet run needs. Measuring tube made of Tantalum, Zirconium. Nominal diameter: DN 8 to 50 (³⁄₈ to 2"). Medium temperature up to +205 °C (+401 °F). |
Transmitter features | Space-saving transmitter – full functionality on the smallest footprint. Time-saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology. Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available. |
Nominal diameter range | DN 8 to 50 (³⁄₈ to 2") |
Wetted materials | Measuring tube: Tantalum 2.5W; 702 (UNS R60702). Connection: Tantalum; 702 (UNS R60702) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.1 %. Volume flow (liquid): ±0.1 %. Mass flow (gas, Tantalum only): ±0.5 %. Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 70 000 kg/h (0 to 2570 lb/min) |
Max. process pressure | PN 40, Class 300, 20K |
Medium temperature range | Tantalum: –50 to +150 °C (–58 to +302 °F). Zirconium: –50 to +205 °C (–58 to +401 °F) |
Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F). Option: –50 to +60 °C (–58 to +140 °F) |
Sensor housing material | 1.4301 (304), corrosion resistant |
Transmitter housing material | Compact: AlSi10Mg, coated. Compact/ultra-compact: 1.4301 (304) |
Degree of protection | Standard: IP66/67, type 4X enclosure. Option: IP69 |
Display/Operation | 4-line backlit display available (no local operation). Configuration via web browser and operating tools possible |
Outputs | 4-20 mA HART (active), Pulse/frequency/switch output (passive) |
Inputs | None |
Digital communication | HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET |
Power supply | DC 20 to 30 V |
Hazardous area approvals | ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC |
Product safety | CE, C-Tick, EAC marking |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025). Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 – Section 7.6a (TÜV SÜD attestation) |
Pressure approvals and certificates | PED, CRN |
Material certificates | 3.1 material |