null
Endress+Hauser

Clamp-on Ultrasonic Flowmeter Proline Prosonic Flow P 500

(No reviews yet) Write a Review
SKU:
Proline Prosonic Flow P 500 Series
MPN:
Proline Prosonic Flow P 500
Weight:
0.00 Grams
+971 4 259 5133

Description

Application

The Prosonic Flow P 500 is an ultrasonic clamp-on flowmeter designed for safe, maintenance-free measurement of both conductive and non-conductive liquids, even in challenging conditions. It measures flow noninvasively and bidirectionally, unaffected by pressure, density, or conductivity, without interrupting the process. With FlowDC, mounting flexibility is maximized, maintaining the specified accuracy with an inlet run of just 2 x DN, even when flow profiles are disturbed. Special coupling pads make this ultrasonic clamp-on system maintenance-free throughout its entire product life cycle. Furthermore, the Prosonic Flow P 500 is available with:

  • High-temperature sensors capable of measuring up to 550 °C (1022 °F)
  • A Petroleum Application Package (PAP) for calculating the standard volume of liquid hydrocarbons
  • Heartbeat Technology, which provides continuous process transparency to detect build-up before it impacts operations

Benefits

  • Flexible mounting – FlowDC minimizes the required inlet runs to an absolute minimum.
  • High safety standards – The Prosonic Flow P 500 is developed according to IEC 61508 functional safety standards and holds international approvals for use in hazardous areas, including Zone 1 and Class I, Division 1.
  • Reliable measurement performance – Proven sensors and a maintenance-free mounting system ensure long-term stability, even in high-temperature applications (up to 550 °C/1022 °F).
  • User-friendly operation – Full remote access is available via the web server, and the touch display provides convenient on-site interaction.
  • Transparent process insights – Heartbeat Technology integrates diagnostics, verification, and monitoring functions, ensuring compliance and process safety at all times.
  • Low capital investment – The cost-effectiveness of the Prosonic Flow P 500 increases as the pipe diameter grows (up to DN 4000/160").

SPECIFICATIONS

Liquids Specifications

Measuring principle

 

Ultrasonic flow

 

Product headline

 

Clamp-on flowmeter for limited spaces in process industries with up to 3 I/Os.

Constant accuracy even when mounted with short inlet run thanks to FlowDC.

Bidirectional measurement of various fluids, e.g. liquid hydrocarbons and chemicals.

 

Sensor features

 

High safety standards – SIL by design,

international hazardous area approvals. Long-term stable signal – maintenance-free

permanent mounting from outside with coupling pads. Reliable measurement on various pipe materials – sensor for GRP and plastic pipes available.

Mounting without process interruption. Wide nominal diameter range: DN 15 to 4000 (½ to 160"). Medium temperature: –40 to +550 °C (–40 to +1022 °F).

 

Transmitter features

 

Full access to process and diagnostic information – numerous, freely combinable I/Os. Reduced complexity and variety –

freely configurable I/O functionality. Integrated verification – Heartbeat Technology.

Remote version with up to 3 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.

 

Nominal diameter range

 

Dual channel, 1 or 2 paths : DN 15 to 4000 (1/2 to 160")

 

Sensor materials

 

Clamp on system:

Sensor holder 1.4301/304, 1.4404/316L

Sensor housing 1.4301/304, 1.4404/316L

Strapping bands 1.4301/304, 1.4404/316L

 

Measured variables

 

Volume flow, sound velocity, flow velocity, totalizer

 

Max. measurement error

 

Volume flow:

±3% o.r. for DN 15

±2% o.r. for DN 25 to DN 200

±2% o.r. above DN 200

 

Measuring range

 

0 to 15 m/s (0 to 50 ft/s)

 

Max. process pressure

 

N/A

 

Medium temperature range

 

DN 15 to 65 (½to 2½"): –40 to +150°C (–40 +302 °F)

DN 50 to 4000 (2 to 160"): –40 to +170°C (–40 to +338 °F)

DN 50 to 600 (2" to 24"): 150°C to 550°C (+302 to +1022 °F)

 

Ambient temperature range

 

–40 to +60 °C (–40 to +140 °F)

–50 to +60 °C (–58 to +140 °F) optional

 

Sensor housing material

 

N/A

 

Transmitter housing material

 

AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L

 

Degree of protection

 

Sensor remote version: IP68 type 6P

Transmitter remote version: IP66/67, Type 4X enclosure

 

Display/Operation

 

4-line backlit display with touch control(operation from outside)

Optional: WLAN

Configuration via local display and operating tools possible

 

Outputs

 

 

 

3 outputs:

4-20 mA HART (active/passive)

4-20 mA (active/passive)

Pulse/frequency/switch output (active/passive)

Double pulse output (active/passive)

Relay output

 

 

Inputs

 

 

Status input

4-20 mA input

 

 

Digital communication

 

 

HART, Modbus RS485

 

Power supply

 

DC 24 V

AC 100 to 230 V

AC 100 to 230 V / DC 24 V (non-hazardous area)

 

Hazardous area approvals

 

ATEX, FM/CSA, EAC, UK Ex, KC

 

Other approvals and certificates

 

 

Other approvals and certificates

 

 

Product safety

 

 

CE, C-tick, EAC-marking

 

Functional safety

 

Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

 

Metrological approvals and certificates

 

Flowmeter verification for all frequencies except 0.3 MHz, reference line size: 5 MHz DN 50, all other frequencies DN 100

 

Verification performed on accredited calibration facilities (acc. to ISO/IEC 17025)

Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a

 

 

Documents

Can't find the information you need? Our datasheets have all the details. Access them here: