Endress+Hauser
Compact Coriolis Flowmeter Cubemass DCI
- SKU:
- Cubemass DCI Series
- MPN:
- Cubemass DCI
- Weight:
- 0.00 Grams
Description
Application
The Cubemass DCI is a reliable sensor designed for measuring extremely low flow rates in applications such as skids, test rigs, and industrial robotics, including tasks like lacquering or surface finishing. It maintains high accuracy even under high pressure or fluctuating flow conditions. Equipment manufacturers appreciate the compact design of the Cubemass DCI and its versatile communication capabilities. The measurement principle is unaffected by physical properties of the fluid, such as viscosity or density. It provides precise measurement of very small quantities of liquids and gases. Device Properties:
- Nominal diameter: DN 1 to 6 (1/24 to 1/4")
- Process pressure capacity: up to 400 bar (5800 psi)
- Medium temperature range: up to +200°C (+392°F)
- Available in both compact and remote versions
- Flexible output options
- Modbus RS485 communication interface
Benefits
- Accurate measurement of small quantities of liquids and gases
- Space-efficient installation with a compact single-tube design
- Reduced need for multiple measuring points with multivariable measurement (flow, density, temperature)
- Ideal for skids due to its lightweight sensor design
- High adaptability for system integration through a wide range of communication interfaces
- Quick and easy commissioning with pre-configured devices
- Automatic data recovery during servicing
Documents
You may want to read this product's catalog. If so, please click to view the Cubemass DCI Series datasheet.SPECIFICATIONS
Liquids Specifications
Measuring principle | Coriolis |
Product headline | Compact sensor for smallest quantities with seamless system integration. Measuring accurately smallest quantities of liquids and gases. |
Sensor features | Space-saving installation – compact single-tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Suitable for skids – lightweight sensor. Nominal diameter: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +200 °C (+392 °F). |
Transmitter features | High flexibility in system integration – wide range of communication interfaces. Fast commissioning – pre-configured devices. Automatic recovery of data for servicing. Device as compact or remote version. Flexible outputs. Modbus RS485. |
Nominal diameter range | DN 1 to 6 (¹⁄₂₄ to ¹⁄₄") |
Wetted materials | Measuring tube: 1.4539 (904L) Connection: 1.4539 (904L); 1.4404 (316/316L) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.5 % Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 1000 kg/h (0 to 37 lb/min) |
Max. process pressure | PN 40, Class 300, 10K, 400 bar (5800 psi) |
Medium temperature range | –50 to +200 °C (–58 to +392 °F) |
Ambient temperature range | Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F) |
Sensor housing material | 1.4301 (304), corrosion resistant |
Transmitter housing material | Powder‐coated die‐cast aluminium |
Degree of protection | IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure |
Display/Operation | 4‐line backlit display with touch control (operation from outside). Configuration via local display and operating tools possible. |
Outputs | 4 modular outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive), phase‐shifted pulse Relay |
Inputs | 1 modular input: status |
Digital communication | HART, Modbus RS485 |
Power supply | DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz) |
Hazardous area approvals | ATEX, IECEx, NEC/CEC, NEPSI |
Other approvals and certificates | 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, CRN |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR |
Material certificates | 3.1 material |
Gas Specifications
Measuring principle | Coriolis |
Product headline | Compact sensor for smallest quantities with seamless system integration. Measuring accurately smallest quantities of liquids and gases. |
Sensor features | Space-saving installation – compact single-tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Suitable for skids – lightweight sensor. Nominal diameter: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +200 °C (+392 °F). |
Transmitter features | High flexibility in system integration – wide range of communication interfaces. Fast commissioning – pre-configured devices. Automatic recovery of data for servicing. Device as compact or remote version. Flexible outputs. Modbus RS485. |
Nominal diameter range | DN 1 to 6 (¹⁄₂₄ to ¹⁄₄") |
Wetted materials | Measuring tube: 1.4539 (904L) Connection: 1.4539 (904L); 1.4404 (316/316L) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.5 % Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 1000 kg/h (0 to 37 lb/min) |
Max. process pressure | PN 40, Class 300, 10K, 400 bar (5800 psi) |
Medium temperature range | –50 to +200 °C (–58 to +392 °F) |
Ambient temperature range | Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F) |
Sensor housing material | 1.4301 (304), corrosion resistant |
Transmitter housing material | Powder‐coated die‐cast aluminium |
Degree of protection | IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure |
Display/Operation | 4‐line backlit display with touch control (operation from outside). Configuration via local display and operating tools possible. |
Outputs | 4 modular outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive), phase‐shifted pulse Relay |
Inputs | 1 modular input: status |
Digital communication | HART, Modbus RS485 |
Power supply | DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz) |
Hazardous area approvals | ATEX, IECEx, NEC/CEC, NEPSI |
Other approvals and certificates | 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, CRN |