null
Endress+Hauser

Compact Coriolis Flowmeter Cubemass DCI

(No reviews yet) Write a Review
SKU:
Cubemass DCI Series
MPN:
Cubemass DCI
Weight:
0.00 Grams
+971 4 259 5133

Description

Application

The Cubemass DCI is a reliable sensor designed for measuring extremely low flow rates in applications such as skids, test rigs, and industrial robotics, including tasks like lacquering or surface finishing. It maintains high accuracy even under high pressure or fluctuating flow conditions. Equipment manufacturers appreciate the compact design of the Cubemass DCI and its versatile communication capabilities. The measurement principle is unaffected by physical properties of the fluid, such as viscosity or density. It provides precise measurement of very small quantities of liquids and gases. Device Properties:

  • Nominal diameter: DN 1 to 6 (1/24 to 1/4")
  • Process pressure capacity: up to 400 bar (5800 psi)
  • Medium temperature range: up to +200°C (+392°F)
  • Available in both compact and remote versions
  • Flexible output options
  • Modbus RS485 communication interface

Benefits

  • Accurate measurement of small quantities of liquids and gases
  • Space-efficient installation with a compact single-tube design
  • Reduced need for multiple measuring points with multivariable measurement (flow, density, temperature)
  • Ideal for skids due to its lightweight sensor design
  • High adaptability for system integration through a wide range of communication interfaces
  • Quick and easy commissioning with pre-configured devices
  • Automatic data recovery during servicing

Documents

You may want to read this product's catalog. If so, please click to view the Cubemass DCI Series datasheet.

SPECIFICATIONS

Liquids Specifications

Measuring principle Coriolis
Product headline Compact sensor for smallest quantities with seamless system integration. Measuring accurately smallest quantities of liquids and gases.
Sensor features Space-saving installation – compact single-tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Suitable for skids – lightweight sensor. Nominal diameter: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +200 °C (+392 °F).
Transmitter features High flexibility in system integration – wide range of communication interfaces. Fast commissioning – pre-configured devices. Automatic recovery of data for servicing. Device as compact or remote version. Flexible outputs. Modbus RS485.
Nominal diameter range DN 1 to 6 (¹⁄₂₄ to ¹⁄₄")
Wetted materials Measuring tube: 1.4539 (904L)
Connection: 1.4539 (904L); 1.4404 (316/316L)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 1000 kg/h (0 to 37 lb/min)
Max. process pressure PN 40, Class 300, 10K, 400 bar (5800 psi)
Medium temperature range –50 to +200 °C (–58 to +392 °F)
Ambient temperature range Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material Powder‐coated die‐cast aluminium
Degree of protection IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation 4‐line backlit display with touch control (operation from outside). Configuration via local display and operating tools possible.
Outputs 4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive), phase‐shifted pulse
Relay
Inputs 1 modular input: status
Digital communication HART, Modbus RS485
Power supply DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
Hazardous area approvals ATEX, IECEx, NEC/CEC, NEPSI
Other approvals and certificates 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, CRN
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Material certificates 3.1 material

Gas Specifications

Measuring principle Coriolis
Product headline Compact sensor for smallest quantities with seamless system integration. Measuring accurately smallest quantities of liquids and gases.
Sensor features Space-saving installation – compact single-tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Suitable for skids – lightweight sensor. Nominal diameter: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +200 °C (+392 °F).
Transmitter features High flexibility in system integration – wide range of communication interfaces. Fast commissioning – pre-configured devices. Automatic recovery of data for servicing. Device as compact or remote version. Flexible outputs. Modbus RS485.
Nominal diameter range DN 1 to 6 (¹⁄₂₄ to ¹⁄₄")
Wetted materials Measuring tube: 1.4539 (904L)
Connection: 1.4539 (904L); 1.4404 (316/316L)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 1000 kg/h (0 to 37 lb/min)
Max. process pressure PN 40, Class 300, 10K, 400 bar (5800 psi)
Medium temperature range –50 to +200 °C (–58 to +392 °F)
Ambient temperature range Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material Powder‐coated die‐cast aluminium
Degree of protection IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation 4‐line backlit display with touch control (operation from outside). Configuration via local display and operating tools possible.
Outputs 4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive), phase‐shifted pulse
Relay
Inputs 1 modular input: status
Digital communication HART, Modbus RS485
Power supply DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
Hazardous area approvals ATEX, IECEx, NEC/CEC, NEPSI
Other approvals and certificates 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, CRN
View AllClose