Application
The Promass P is designed specifically for sterile processes in the life sciences industry, catering to biotechnology applications that demand strict adherence to regulations and guidelines. Featuring the advanced Promass P 500 remote transmitter, it offers maximum flexibility in installation and ensures operational safety even in challenging environments. With integrated Heartbeat Technology, it ensures continuous compliance and process safety. Its measuring principle functions independently of the physical properties of fluids, such as viscosity or density, making it ideal for a wide range of applications under sterile conditions within the life sciences sector.
Device Features
- Conforms to ASME BPE, 3-A, and EHEDG standards with low delta ferrite content
- Electropolished measuring tube made of 1.4435 (316L) stainless steel
- Rapid recovery from CIP/SIP processes
- Remote version with up to 4 input/output connections
- Backlit display with touch control and WLAN access
- Standard cable connection between the sensor and transmitter
Benefits
- Ensures the highest process quality with full compliance to industry standards
- Reduces the number of measuring points required through multivariable measurement (flow, density, and temperature)
- Saves installation space by eliminating the need for in-/outlet runs
- Provides full access to process and diagnostic information via flexible I/Os and Ethernet connectivity
- Simplifies system design with configurable I/O functionality
- Features integrated verification through Heartbeat Technology for enhanced reliability and safety
Documents
You may want to read this product's catalog. If so, please click to view the Proline Promass P 500 Series datasheet.SPECIFICATIONS
Liquids Specifications
Measuring principle | Coriolis |
Product headline | Specialist for life sciences, as remote version with up to 4 I/Os. Dedicated to applications under sterile conditions in the life sciences industry. |
Sensor features | Highest process quality – fully compliant to industry requirements. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space-saving installation – no in-/outlet run needs. ASME BPE, 3-A and EHEDG conform & low delta ferrite. Electropolished measuring tube in 1.4435 (316L). |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Fast recovery from CIP/SIP. Remote version with up to 4 I/Os; hygienic sensor connection housing with IP69. Backlit display with touch control and WLAN access. |
Nominal diameter range | DN 8 to 50 (⅜ to 2") |
Wetted materials | Measuring tube: 1.4435 (316L); Connection: 1.4435 (316L); 1.4404 (316/316L) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.10 %, Volume flow (liquid): ±0.10 %, Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 70 000 kg/h (0 to 2570 lb/min) |
Max. process pressure | PN 40, Class 150, 20K |
Medium temperature range | Standard: –50 to +150 °C (–58 to +302 °F), Option: –50 to +205 °C (–58 to +401 °F) |
Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F), Option: –50 to +60 °C (–58 to +140 °F) |
Sensor housing material | 1.4301 (304), corrosion resistant |
Sensor connection housing (standard) | AlSi10Mg, coated |
Sensor connection housing (option) | 1.4301 (304); 1.4404 (316L) |
Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonate |
Degree of protection | Sensor remote version (standard): IP66/67, type 4X enclosure; Sensor remote version (option): IP69; Transmitter remote version: IP66/67, Type 4X enclosure |
Display/Operation | 4-line backlit display with touch control (operation from outside). Configuration via local display and operating tools possible. |
Outputs | 4 outputs: 4-20 mA HART (active/passive), 4-20 mA WirelessHART, 4-20 mA (active/passive), Pulse/frequency/switch output (active/passive), Double pulse output (active/passive), Relay output |
Inputs | Status input, 4-20 mA input |
Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
Power supply | DC 24 V, AC 100 to 230 V, AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
Product safety | CE, C-tick, EAC marking |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
Pressure approvals and certificates | PED, CRN |
Material certificates | 3.1 material |
Hygienic approvals and certificates | 3-A, EHEDG, ASME BPE, ISPE, cGMP |
Gas Specifications
Measuring principle | Coriolis |
Product headline | Specialist for life sciences, as remote version with up to 4 I/Os. Dedicated to applications under sterile conditions in the life sciences industry. |
Hygienic approvals and certificates | cGMP |
Density Specifications
Measuring principle | Coriolis |
Product Headline | Specialist for life sciences, as remote version with up to 4 I/Os. Dedicated to applications under sterile conditions in the life sciences industry. |
Sensor features | Highest process quality – fully compliant to industry requirements. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. ASME BPE, 3‐A and EHEDG conform & low delta ferrite. Electropolished measuring tube in 1.4435 (316L). |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Fast recovery from CIP/SIP. Remote version with up to 4 I/Os; hygienic sensor connection housing with IP69. Backlit display with touch control and WLAN access. |
Density/Concentration Specifications
Measuring principle | Coriolis |
Product Headline | Specialist for life sciences, as remote version with up to 4 I/Os. Dedicated to applications under sterile conditions in the life sciences industry. |
Sensor features | Highest process quality – fully compliant to industry requirements. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. ASME BPE, 3‐A and EHEDG conform & low delta ferrite. Electropolished measuring tube in 1.4435 (316L). |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Fast recovery from CIP/SIP. Remote version with up to 4 I/Os; hygienic sensor connection housing with IP69. Backlit display with touch control and WLAN access. |
Nominal diameter range | DN 8 to 50 (⅜ to 2") |
Wetted materials | Measuring tube: 1.4435 (316L); Connection: 1.4435 (316L); 1.4404 (316/316L) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 70 000 kg/h (0 to 2570 lb/min) |
Max. process pressure | PN 40, Class 150, 20K |
Medium temperature range | Standard: –50 to +150 °C (–58 to +302 °F) Option: –50 to +205 °C (–58 to +401 °F) |
Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
Sensor housing material | 1.4301 (304), corrosion resistant Sensor connection housing (standard): AlSi10Mg, coated Sensor connection housing (option): 1.4301 (304); 1.4404 (316L) |
Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonate |
Degree of protection | Sensor remote version (standard): IP66/67, type 4X enclosure Sensor remote version (option): IP69 Transmitter remote version: IP66/67, Type 4X enclosure |
Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
Outputs | 4 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
Inputs | Status input 4-20 mA input |
Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
Product safety | CE, C-tick, EAC marking |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
Pressure approvals and certificates | PED, CRN |
Material certificates | 3.1 material |
Hygienic approvals and certificates | 3-A, EHEDG, ASME BPE, ISPE, cGMP |