null
Endress+Hauser

Coriolis Flowmeter for the Smallest Flow Rates Cubemass

(No reviews yet) Write a Review
SKU:
Cubemass Series
MPN:
Cubemass
Weight:
0.00 Grams
+971 4 259 5133

Description

Application

Cubemass is a reliable sensor specifically designed for measuring the smallest flow rates in applications such as skids, test rigs, and industrial robotics. It excels in scenarios like lacquering or surface finishing. High pressure and fluctuating flow conditions do not impact its precision. Manufacturers prefer the Cubemass for its compact design as a Coriolis sensor. The measurement principle functions independently of the physical properties of the fluid, such as viscosity or density, allowing for accurate measurement of even the smallest quantities of liquids and gases. Device Features:

  • Nominal diameter: DN 1 to 6 (1/24" to 1/4")
  • Process pressure: up to 400 bar (5800 psi)
  • Medium temperature: up to +200 °C (+392 °F)
  • Durable transmitter housing
  • Modbus RS485 communication
  • Pulse output

Benefits

  • Precise measurement of small amounts of liquids and gases
  • Space-saving installation due to its compact single-tube design
  • Reduced need for additional measuring points with multivariable measurement (flow, density, and temperature)
  • Ideal for skids thanks to its lightweight sensor
  • Cost-effective with low power consumption
  • Quick setup with pre-configured devices
  • Easy maintenance with automatic data recovery during servicing

Documents

You may want to read this product's catalog. If so, please click to view the Cubemass Series datasheet.

SPECIFICATIONS

Liquids Specifications

Measuring principle Coriolis
Product headline Compact sensor for smallest quantities with easy system integration. Measuring accurately smallest quantities of liquids and gases.
Sensor features Space-saving installation – compact single-tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Suitable for skids – lightweight sensor. Nominal diameter: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +200 °C (+392 °F).
Transmitter features Cost savings – very low power consumption. Fast commissioning – pre-configured devices. Automatic recovery of data for servicing. Robust transmitter housing. Modbus RS485. Pulse output.
Nominal diameter range DN 1 to 6 (¹⁄₂₄ to ¹⁄₄")
Wetted materials Measuring tube: 1.4539 (904L)
Connection: 1.4539 (904L); 1.4404 (316/316L)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 1000 kg/h (0 to 37 lb/min)
Max. process pressure PN 40, Class 300, 10K, 400 bar (5800 psi)
Medium temperature range –50 to +200 °C (–58 to +392 °F)
Ambient temperature range Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material Powder‐coated die‐cast aluminium
Degree of protection IP67, type 4X enclosure
Display/Operation No local operation
Configuration via operating tools possible
Outputs Pulse/frequency/switch output (passive), phase‐shifted pulse
Inputs None
Digital communication Modbus RS485
Power supply DC 10 to 30 V
AC 20 to 28 V
Hazardous area approvals ATEX, IECEx, NEC/CEC, NEPSI
Other approvals and certificates 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
CRN
Metrological approvals and certificates 3.1 material
Pressure approvals and certificates CRN

Gas Specifications

Measuring principle Coriolis
Product headline Compact sensor for smallest quantities with easy system integration. Measuring accurately smallest quantities of liquids and gases.
Sensor features Space-saving installation – compact single-tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Suitable for skids – lightweight sensor. Nominal diameter: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +200 °C (+392 °F).
Transmitter features Cost savings – very low power consumption. Fast commissioning – pre-configured devices. Automatic recovery of data for servicing. Robust transmitter housing. Modbus RS485. Pulse output.
Nominal diameter range DN 1 to 6 (¹⁄₂₄ to ¹⁄₄")
Wetted materials Measuring tube: 1.4539 (904L)
Connection: 1.4539 (904L); 1.4404 (316/316L)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 1000 kg/h (0 to 37 lb/min)
Max. process pressure PN 40, Class 300, 10K, 400 bar (5800 psi)
Medium temperature range –50 to +200 °C (–58 to +392 °F)
Ambient temperature range Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material Powder‐coated die‐cast aluminium
Degree of protection IP67, type 4X enclosure
Display/Operation No local operation
Configuration via operating tools possible
Outputs Pulse/frequency/switch output (passive), phase‐shifted pulse
Inputs None
Digital communication Modbus RS485
Power supply DC 10 to 30 V
AC 20 to 28 V
Hazardous area approvals ATEX, IECEx, NEC/CEC, NEPSI
Other approvals and certificates 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
CRN
View AllClose