Endress+Hauser
Coriolis Flowmeter for the Smallest Flow Rates Cubemass
- SKU:
- Cubemass Series
- MPN:
- Cubemass
- Weight:
- 0.00 Grams
Description
Application
Cubemass is a reliable sensor specifically designed for measuring the smallest flow rates in applications such as skids, test rigs, and industrial robotics. It excels in scenarios like lacquering or surface finishing. High pressure and fluctuating flow conditions do not impact its precision. Manufacturers prefer the Cubemass for its compact design as a Coriolis sensor. The measurement principle functions independently of the physical properties of the fluid, such as viscosity or density, allowing for accurate measurement of even the smallest quantities of liquids and gases. Device Features:
- Nominal diameter: DN 1 to 6 (1/24" to 1/4")
- Process pressure: up to 400 bar (5800 psi)
- Medium temperature: up to +200 °C (+392 °F)
- Durable transmitter housing
- Modbus RS485 communication
- Pulse output
Benefits
- Precise measurement of small amounts of liquids and gases
- Space-saving installation due to its compact single-tube design
- Reduced need for additional measuring points with multivariable measurement (flow, density, and temperature)
- Ideal for skids thanks to its lightweight sensor
- Cost-effective with low power consumption
- Quick setup with pre-configured devices
- Easy maintenance with automatic data recovery during servicing
Documents
You may want to read this product's catalog. If so, please click to view the Cubemass Series datasheet.SPECIFICATIONS
Liquids Specifications
Measuring principle | Coriolis |
Product headline | Compact sensor for smallest quantities with easy system integration. Measuring accurately smallest quantities of liquids and gases. |
Sensor features | Space-saving installation – compact single-tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Suitable for skids – lightweight sensor. Nominal diameter: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +200 °C (+392 °F). |
Transmitter features | Cost savings – very low power consumption. Fast commissioning – pre-configured devices. Automatic recovery of data for servicing. Robust transmitter housing. Modbus RS485. Pulse output. |
Nominal diameter range | DN 1 to 6 (¹⁄₂₄ to ¹⁄₄") |
Wetted materials | Measuring tube: 1.4539 (904L) Connection: 1.4539 (904L); 1.4404 (316/316L) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.5 % Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 1000 kg/h (0 to 37 lb/min) |
Max. process pressure | PN 40, Class 300, 10K, 400 bar (5800 psi) |
Medium temperature range | –50 to +200 °C (–58 to +392 °F) |
Ambient temperature range | Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F) |
Sensor housing material | 1.4301 (304), corrosion resistant |
Transmitter housing material | Powder‐coated die‐cast aluminium |
Degree of protection | IP67, type 4X enclosure |
Display/Operation | No local operation Configuration via operating tools possible |
Outputs | Pulse/frequency/switch output (passive), phase‐shifted pulse |
Inputs | None |
Digital communication | Modbus RS485 |
Power supply | DC 10 to 30 V AC 20 to 28 V |
Hazardous area approvals | ATEX, IECEx, NEC/CEC, NEPSI |
Other approvals and certificates | 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR CRN |
Metrological approvals and certificates | 3.1 material |
Pressure approvals and certificates | CRN |
Gas Specifications
Measuring principle | Coriolis |
Product headline | Compact sensor for smallest quantities with easy system integration. Measuring accurately smallest quantities of liquids and gases. |
Sensor features | Space-saving installation – compact single-tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Suitable for skids – lightweight sensor. Nominal diameter: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +200 °C (+392 °F). |
Transmitter features | Cost savings – very low power consumption. Fast commissioning – pre-configured devices. Automatic recovery of data for servicing. Robust transmitter housing. Modbus RS485. Pulse output. |
Nominal diameter range | DN 1 to 6 (¹⁄₂₄ to ¹⁄₄") |
Wetted materials | Measuring tube: 1.4539 (904L) Connection: 1.4539 (904L); 1.4404 (316/316L) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.5 % Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 1000 kg/h (0 to 37 lb/min) |
Max. process pressure | PN 40, Class 300, 10K, 400 bar (5800 psi) |
Medium temperature range | –50 to +200 °C (–58 to +392 °F) |
Ambient temperature range | Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F) |
Sensor housing material | 1.4301 (304), corrosion resistant |
Transmitter housing material | Powder‐coated die‐cast aluminium |
Degree of protection | IP67, type 4X enclosure |
Display/Operation | No local operation Configuration via operating tools possible |
Outputs | Pulse/frequency/switch output (passive), phase‐shifted pulse |
Inputs | None |
Digital communication | Modbus RS485 |
Power supply | DC 10 to 30 V AC 20 to 28 V |
Hazardous area approvals | ATEX, IECEx, NEC/CEC, NEPSI |
Other approvals and certificates | 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR CRN |