Endress+Hauser
Corrosion-resistant Coriolis Flowmeter Proline Promass H 500
- SKU:
- Proline Promass H 500 Series
- MPN:
- Proline Promass H 500
- Weight:
- 0.00 Grams
Description
Application
The Promass H is designed for applications that require maximum corrosion resistance and delivers highly accurate measurements, ensuring optimal safety when handling chemically aggressive fluids. With its advanced remote transmitter, the Promass H 500 offers flexibility in installation and enhanced operational safety, even in challenging environments. The integrated Heartbeat Technology ensures continuous process safety. The measuring principle functions independently of fluid properties such as viscosity or density, providing precise measurement for liquids and gases in corrosive environments requiring the highest level of resistance.
Device Properties
- Measuring tube material: Tantalum, Zirconium
- Nominal diameter range: DN 8 to 50 (3/8 to 2”)
- Medium temperature range: Up to +205°C (+401°F)
- Remote version with up to 4 I/Os
- Backlit display with touch control and WLAN access
- Standard cable connection between the sensor and transmitter
Benefits
- Enhanced safety: Corrosion-resistant wetted parts ensure maximum protection when handling chemically aggressive fluids.
- Multivariable measurement: Reduces the need for multiple process measuring points by providing flow, density, and temperature data in one device.
- Space efficiency: Requires no in/outlet runs, simplifying installation.
- Comprehensive access: Offers full access to process and diagnostic information with various I/O configurations and Ethernet connectivity.
- Simplified setup: Freely configurable I/O functionality reduces complexity and equipment variety.
- Built-in verification: Heartbeat Technology provides integrated, continuous verification for reliable operation.
Documents
You may want to read this product's catalog. If so, please click to view the Proline Promass H 500 Series datasheet.SPECIFICATIONS
Liquids Specifications
Measuring principle | Coriolis |
Product headline | Chemically resistant single-tube flowmeter, as remote version with up to 4 I/Os. Highly accurate measurement of liquids and gases in applications requiring highest corrosion resistance. |
Sensor features | Maximum safety for chemically aggressive fluids – corrosion‐resistant wetted parts. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space-saving installation – no in-/outlet run needs. Measuring tube made of Tantalum, Zirconium. Nominal diameter: DN 8 to 50 (³⁄₈ to 2"). Medium temperature up to +205 °C (+401 °F). |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Nominal diameter range | DN 8 to 50 (³⁄₈ to 2") |
Wetted materials | Measuring tube: Tantalum 2.5W; 702 (UNS R60702). Connection: Tantalum; 702 (UNS R60702) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.10 %. Volume flow (liquid): ±0.10 %. Mass flow (gas, Tantalum only): ±0.50 %. Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 70 000 kg/h (0 to 2570 lb/min) |
Max. process pressure | PN 40, Class 300, 20K |
Medium temperature range | Tantalum: –50 to +150 °C (–58 to +302 °F). Zirconium: –50 to +205 °C (–58 to +401 °F) |
Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F). Option: –50 to +60 °C (–58 to +140 °F) |
Sensor housing material | 1.4301 (304), corrosion resistant. Sensor connection housing (standard): AlSi10Mg, coated. Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L |
Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat |
Degree of protection | Sensor remote version (standard): IP66/67, type 4X enclosure. Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure |
Display/Operation | 4-line backlit display with touch control (operation from outside). Configuration via local display and operating tools possible |
Outputs | 4 outputs:
|
Inputs | Status input, 4-20 mA input |
Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
Power supply | DC 24 V, AC 100 to 230 V, AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
Product safety | CE, C-tick, EAC marking |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025). Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
Pressure approvals and certificates | PED, CRN |
Material certificates | 3.1 material |
Gas Specifications
Measuring principle | Coriolis |
Product headline | Chemically resistant single-tube flowmeter, as remote version with up to 4 I/Os. Highly accurate measurement of liquids and gases in applications requiring highest corrosion resistance. |
Sensor features | Maximum safety for chemically aggressive fluids – corrosion‐resistant wetted parts. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space-saving installation – no in-/outlet run needs. Measuring tube made of Tantalum, Zirconium. Nominal diameter: DN 8 to 50 (³⁄₈ to 2"). Medium temperature up to +205 °C (+401 °F). |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Nominal diameter range | DN 8 to 50 (³⁄₈ to 2") |
Wetted materials | Measuring tube: Tantalum 2.5W; 702 (UNS R60702). Connection: Tantalum; 702 (UNS R60702) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.10 %. Volume flow (liquid): ±0.10 %. Mass flow (gas, Tantalum only): ±0.50 %. Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 70 000 kg/h (0 to 2570 lb/min) |
Max. process pressure | PN 40, Class 300, 20K |
Medium temperature range | Tantalum: –50 to +150 °C (–58 to +302 °F). Zirconium: –50 to +205 °C (–58 to +401 °F) |
Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F). Option: –50 to +60 °C (–58 to +140 °F) |
Sensor housing material | 1.4301 (304), corrosion resistant. Sensor connection housing (standard): AlSi10Mg, coated. Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L |
Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat |
Degree of protection | Sensor remote version (standard): IP66/67, type 4X enclosure. Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure |
Display/Operation | 4-line backlit display with touch control (operation from outside). Configuration via local display and operating tools possible |
Outputs | 4 outputs:
|
Inputs | Status input, 4-20 mA input |
Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
Power supply | DC 24 V, AC 100 to 230 V, AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
Product safety | CE, C-tick, EAC marking |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025). Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
Pressure approvals and certificates | PED, CRN |
Material certificates | 3.1 material |
Density Specifications
Measuring principle | Coriolis |
Product Headline | Chemically resistant single-tube flowmeter, as remote version with up to 4 I/Os. Highly accurate measurement of liquids and gases in applications requiring highest corrosion resistance. |
Sensor features | Maximum safety for chemically aggressive fluids – corrosion‐resistant wetted parts. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space-saving installation – no in-/outlet run needs. Measuring tube made of Tantalum, Zirconium. Nominal diameter: DN 8 to 50 (³⁄₈ to 2"). Medium temperature up to +205 °C (+401 °F). |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Density/Concentration Specification
Measuring principle | Coriolis |
Product headline | Chemically resistant single-tube flowmeter, as remote version with up to 4 I/Os. Highly accurate measurement of liquids and gases in applications requiring highest corrosion resistance. |
Sensor features | Maximum safety for chemically aggressive fluids – corrosion‐resistant wetted parts. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space-saving installation – no in-/outlet run needs. Measuring tube made of Tantalum, Zirconium. Nominal diameter: DN 8 to 50 (³⁄₈ to 2"). Medium temperature up to +205 °C (+401 °F). |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Nominal diameter range | DN 8 to 50 (³⁄₈ to 2") |
Wetted materials | Measuring tube: Tantalum 2.5W; 702 (UNS R60702) Connection: Tantalum; 702 (UNS R60702) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.10 % Volume flow (liquid): ±0.10 % Mass flow (gas, Tantalum only): ±0.50 % Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 70 000 kg/h (0 to 2570 lb/min) |
Max. process pressure | PN 40, Class 300, 20K |
Medium temperature range | Tantalum: –50 to +150 °C (–58 to +302 °F) Zirconium: –50 to +205 °C (–58 to +401 °F) |
Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
Sensor housing material | 1.4301 (304), corrosion resistant |
Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonate |
Degree of protection | Sensor remote version (standard): IP66/67, type 4X enclosure Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure |
Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
Outputs | 4 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
Inputs | Status input 4-20 mA input |
Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
Product safety | CE, C-tick, EAC marking |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
Pressure approvals and certificates | PED, CRN |
Material certificates | 3.1 material |