null
Endress+Hauser

Cost-effective Coriolis Flowmeter Proline Promass E 200

(No reviews yet) Write a Review
SKU:
Proline Promass E 200 Series
MPN:
Proline Promass E 200
Weight:
0.00 Grams
+971 4 259 5133

Description

Application

The durable Promass E is widely recognized for its reliability in accurately measuring liquids and gases across a variety of standard applications in the chemical industry. With true loop-powered technology, the Proline E 200 ensures economical and easy integration into existing systems. Its intrinsically safe design (Ex ia) guarantees the highest level of operational safety in hazardous environments. Additionally, Heartbeat Technology continuously ensures process safety. The measuring principle functions independently of physical properties such as viscosity or density, delivering precise measurement for a broad range of liquid and gas applications. Device Features:

  • Compact dual-tube sensor
  • Medium temperature capability up to +150 °C (+302 °F)
  • Handles process pressures up to 100 bar (1450 psi)
  • Loop-powered technology for cost-efficiency
  • Sturdy dual-compartment housing
  • Ensures plant safety with global certifications (SIL, Hazardous area)

Benefits

  • Cost-effective – A versatile alternative to traditional volumetric flowmeters.
  • Reduced measuring points – Provides multivariable measurements, including flow, density, and temperature.
  • Compact installation – Does not require inlet/outlet runs, saving space.
  • Easy wiring – Features a separate connection compartment for convenient setup.
  • Secure operation – Equipped with a display featuring touch controls and backlighting, allowing operation without opening the device.
  • Integrated verification – Heartbeat Technology ensures ongoing self-diagnosis and verification.

SPECIFICATIONS

Liquids Specifications

Measuring principle

 


 

Coriolis

 

 

 

Product headline

 

 

Genuine loop-powered flowmeter for minimized cost of ownership.

Accurate measurement of liquids and gases for a wide range of standard applications.

 

Sensor features

 

 

Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.

Compact dual-tube sensor. Medium temperature up to +150 °C (+302 °F). Process pressure up to 100 bar (1450 psi).

 

 

Transmitter features

 

 

Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.

Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).

 

 

Nominal diameter range

 

 

DN 8 to 50 (⅜ to 2")

 

Wetted materials

 

Measuring tube: 1.4539 (904L)

Connection: 1.4404 (316/316L)

 

Measured variables

 

Mass flow, density, temperature, volume flow, corrected volume flow, reference density

 

Max. measurement error

 

Mass flow (liquid): ±0.25 % (standard)

Volume flow (liquid): ±0.25 %

Mass flow (gas): ±0.50 %

Density (liquid): ±0.0005 g/cm³

 

Measuring range

 

 

0 to 70 000 kg/h (0 to 2570 lb/min)

 

Max. process pressure

 

PN 100, Class 600, 63K

 

Medium temperature range

 

–40 to +150 °C (–40 to +302 °F)

Ambient temperature range

 

 

–40 to +60 °C (–40 to +140 °F)

 

 

Sensor housing material

 

 

1.4301 (304), corrosion resistant

 

Transmitter housing material

 

AlSi10Mg, coated

 

Degree of protection

 

IP66/67, type 4X enclosure

 

Display/Operation

 

4‐line backlit display with touch control

(operation from outside)

Configuration via local display and operating tools possible

Remote display available

 

Outputs

 

 

4‐20 mA HART (passive)

4‐20 mA (passive)

Pulse/frequency/switch output (passive)

 

Inputs

 

 

None

 

 

Digital communication

 

HART, PROFIBUS PA, FOUNDATION Fieldbus

Power supply

 

DC 18 to 35 V (4‐20 mA HART with/without

pulse/frequency/switch)

DC 18 to 30 V (20 mA HART, 4‐20 mA)

DC 9 to 32 V (PROFIBUS PA)

Hazardous area approvals

 

ATEX, IECEx, cCSAus, JPN, UK Ex

Product safety

 

 

CE, C-TICK

 

 

Functional safety

 

 

Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

 

Metrological approvals and certificates

 

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)

 

 

Pressure approvals and certificates

 

PED, CRN

 

Material certificates

 

 

3.1 material

 

 

Hygienic approvals and certificates

 

 

3-A, EHEDG, cGMP

 

Gas Specifications

Measuring principle

 

 

Coriolis

 

 

Product headline

 

 

Genuine loop-powered flowmeter for minimized cost of ownership.

Accurate measurement of liquids and gases for a wide range of standard applications.

 

Sensor features

 

 

Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.

Compact dual-tube sensor. Medium temperature up to +150 °C (+302 °F). Process pressure up to 100 bar (1450 psi).

 

 

Transmitter features

 

 

Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.

Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).

 

 Nominal diameter range  

DN 8 to 50 (⅜ to 2")

 

 

Wetted materials

 

 

Measuring tube: 1.4539 (904L)

Connection: 1.4404 (316/316L)

 

 

Measured variables

 

 

Mass flow, density, temperature, volume flow, corrected volume flow, reference density

 

 

Max. measurement error

 

 

Mass flow (liquid): ±0.25 % (standard)

Volume flow (liquid): ±0.25 %

Mass flow (gas): ±0.50 %

Density (liquid): ±0.0005 g/cm³

 

 

Measuring range

 

 

0 to 70 000 kg/h (0 to 2570 lb/min)

 

Max. process pressure

 

PN 100, Class 600, 63K

 

Medium temperature range

 

 

–40 to +150 °C (–40 to +302 °F)

 

 

Ambient temperature range

 

 

–40 to +60 °C (–40 to +140 °F)

 

 

Sensor housing material

 

 

1.4301 (304), corrosion resistant

 

 

Transmitter housing material

 

 

AlSi10Mg, coated

 

Degree of protection

IP66/67, type 4X enclosure

 

 

Display/Operation

 

 

4‐line backlit display with touch control

(operation from outside)

Configuration via local display and operating tools possible

Remote display available

 

 

Outputs

 

4‐20 mA HART (passive)

4‐20 mA (passive)

Pulse/frequency/switch output (passive)

Inputs

 

None

 

Digital communication

 

HART, PROFIBUS PA, FOUNDATION Fieldbus

 

Power supply

 

 

DC 18 to 35 V (4‐20 mA HART with/without pulse/frequency/switch)

DC 18 to 30 V (20 mA HART, 4‐20 mA)

DC 9 to 32 V (PROFIBUS PA)

 

 

Hazardous area approvals

 

 

ATEX, IECEx, cCSAus, JPN, UK Ex

 

 

 

Product safety

 

 

CE, C-Tick, EAC marking

 

 

 

Functional safety

 

 

Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

 

Metrological approvals and certificates

 

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)

 

Pressure approvals and certificates

 

PED, CRN

 

Material certificates

 

 

3.1 material

 

 

Hygienic approvals and certificates

 

 

3-A, EHEDG, cGMP

 

Density Concentration Specifications

 

Measuring principle

 

 

Coriolis

 

 

Product headline

 

 

Genuine loop-powered flowmeter for minimized cost of ownership.

Accurate measurement of liquids and gases for a wide range of standard applications.

 

Sensor features

 

 

Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.

Compact dual-tube sensor. Medium temperature up to +150 °C (+302 °F). Process pressure up to 100 bar (1450 psi).

 

 

Transmitter features

 

 

Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.

Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).

 

 

Nominal diameter range

 

 

DN 8 to 50 (⅜ to 2")

 

 

Wetted materials

 

 

Measuring tube: 1.4539 (904L)

Connection: 1.4404 (316/316L)

 

Measured variables

 

 

Mass flow, density, temperature, volume flow, corrected volume flow, reference density

 

 

Max. measurement error

 

 

Mass flow (liquid): ±0.25 % (standard)

Volume flow (liquid): ±0.25 %

Mass flow (gas): ±0.50 %

Density (liquid): ±0.0005 g/cm³

 

 Measuring range  

0 to 70 000 kg/h (0 to 2570 lb/min)

 

 

Max. process pressure

 

 

PN 100, Class 600, 63K

 

 

Medium temperature range

 

 

–40 to +150 °C (–40 to +302 °F)

 

 

Ambient temperature range

 

 

–40 to +60 °C (–40 to +140 °F)

 

 

Sensor housing material

 

 

1.4301 (304), corrosion resistant

 

 

Transmitter housing material

 

 

AlSi10Mg, coated

 

Degree of protection

 

 

IP66/67, type 4X enclosure

 

 Display/Operation  

4‐line backlit display with touch control (operation from outside)

Configuration via local display and operating tools possible

Remote display available

 

 

Outputs

 

 

4‐20 mA HART (passive)

4‐20 mA (passive)

Pulse/frequency/switch output (passive)

 

Inputs

 

 

None

 

 

 

Digital communication

 

 

HART, PROFIBUS PA, FOUNDATION Fieldbus

Power supply

 

DC 18 to 35 V (4‐20 mA HART with/without pulse/frequency/switch)

DC 18 to 30 V (20 mA HART, 4‐20 mA)

DC 9 to 32 V (PROFIBUS PA)

 

Hazardous area approvals

 

 

ATEX, IECEx, cCSAus, JPN, UK Ex

 

 

Product safety

 

 CE, C-TICK
 

Functional safety

 

 

Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

 

Metrological approvals and certificates

 

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)

 

Pressure approvals and certificates

 

PED, CRN

 

 

Material certificates

 

 

3.1 material

 

 

Hygienic approvals and certificates

 

 

3-A, EHEDG, cGMP

 

 


 

Documents

You may want to read this product's catalog. If so, please click to view the Proline Promass E 200 Series datasheet.
View AllClose