Endress+Hauser
Cost-effective Electromagnetic Flowmeter Magphant
- SKU:
- Cost-effective Electromagnetic Flowmeter Magphant
- Weight:
- 0.00 Grams
Description
Application
The cost-effective and compact Magphant flowmeter is perfectly suited for water applications in utility systems. It offers reliable and highly repeatable measurements, ensuring easy and versatile use while supporting safe operation of processes and plants.
Its bidirectional measurement principle is nearly unaffected by changes in pressure, density, temperature, or viscosity, making it ideal for all water-related applications in utility environments.
Device Features
- Compact and space-saving design
- Nominal diameter options: DN 15 to 2000 (1/2" to 80")
- Suitable for use with both steel and plastic pipes
- Adjustable switch point via rotary switch
- Includes current and relay outputs
- Certifications: ATEX, FM, CSA
Benefits
- High plant availability: Provides reliable flow information
- Energy efficiency: No pressure loss due to cross-sectional constriction
- Maintenance-free: No moving parts
- Process safety: Device self-monitoring and reliable operation, even in the event of empty piping
- Product safety: Integrated test function for verifying proper electronics operation
- Ease of use: Full-scale value setting via potentiometer
SPECIFICATIONS
Pressure Specifications
Measuring principle |
Electromagnetic Product headline |
Sensor features | High plant availability – reliable flow information. Energy-saving flow measurement – no pressure loss due to cross section constriction. Maintenance-free – no moving parts. Compact, space-saving design. Nominal diameter: DN 15 to 2000 (½ to 80"). |
Transmitter features | Process safety – device self-monitoring and reliable monitoring even with empty piping. Product safety – integrated testing to check correct functioning of the electronics. Easy operation – potentiometer setting of full-scale value. Switch point setting via rotary switch. Current output and relay output. |
Nominal diameter range |
DN15 to DN2000 1/2" to 80" |
Wetted materials | 1.4435/316L |
Measured variables | Volume flow |
Max. measurement error | 2% |
Measuring range | 0 to 56'550 m3/h |
Max. process pressure | 0 to 16 bar abs |
Medium temperature range |
-20 to +120°C (-4 to +248°F) |
Ambient temperature range | -20...60 °C (-4 to 140°F) |
Sensor housing material | Die-cast aluminium, epoxy powder coated |
Degree of protection | IP 66 / NEMA 4X / Type 4X |
Display/Operation | Test function |
Outputs |
4 to 20 mA Relay |
Inputs | None |
Power supply | 24 V DC (20...30 V DC) |
Hazardous area approvals |
FM CSA |
Product safety | CE, EAC |
Documents
You may want to read this product's catalog. If so, please click to view the Endress+Hauser Magphant Series datasheet.