null
Endress+Hauser

Cost-effective Ultrasonic Level Transmitter Prosonic FMU40

(No reviews yet) Write a Review
SKU:
Cost-effective Ultrasonic Level Transmitter Prosonic FMU40 series
Weight:
0.00 Grams
Call us: +971 4 259 5133

Description

Application

The Prosonic FMU40 sensor is designed for non-contact level measurement in a variety of media, including fluids, pastes, coarse bulk materials, as well as for flow measurement in open channels or at weirs. This compact transmitter, available in two-wire or four-wire configurations, is versatile for use in storage tanks, with agitators, and on stockpiles or conveyor belts. Its on-site display allows users to view the envelope curve for easy diagnostics. Additionally, the sensor features a linearization function (up to 32 points), enabling the conversion of measured values into any desired unit, such as length, volume, or flow rate.

  • Two-wire or four-wire configuration for continuous non-contact level and flow measurement
  • Process connection: Thread
  • Operating temperature range: -40 to +80°C (-40 to +176°F)
  • Pressure range: +0.7 to +3bar (+10 to +44psi)
  • Maximum measuring range: Liquids up to 5m (16ft), Solids up to 2m (6.5ft)
  • Blocking distance: Liquids and solids at 0.25m (0.8ft)
  • International certifications for explosion protection

 


Benefits

  • Reliable non-contact level measurement
  • Fast and easy setup with menu-guided, four-line plain text display, offering seven language options
  • On-site display provides envelope curves for straightforward diagnostics
  • Hermetically sealed and fully potted sensor design
  • Chemical-resistant PVDF sensor housing
  • Calibration without needing to fill or empty tanks
  • Built-in temperature sensor for automatic sound velocity correction based on temperature changes

 

SPECIFICATIONS

Pressure Specifications

Measuring principle Ultrasonic
Characteristic / Application Compact ultrasonic transmitter
Supply / Communication 2-wire HART
Accuracy +/- 2 mm or +/- 0.2 % of set measuring range
Ambient temperature

-40 °C ... 80 °C

(-40 °F ... 176 °F)

Process temperature

-40 °C ... 80 °C

(-40 °F ... 176 °F)

Process pressure / max. overpressure limit

0.7 bar ... 3 bar abs

(10 psi ... 44 psi)

Main wetted parts PVDF

Process connection

G / NPT 1 1/2"
Blocking distance 0.25 m (0.8 ft)
Max. measurement distance

Liquids: 5 m (16 ft),

Solids: 2 m (6.6 ft)

Communication 4...20 mA HART
Certificates / Approvals ATEX, FM, CSA, TIIS, INMETRO, NEPSI
Application limits

For higher resistance:

FMU42/FDU9x

Foam / high turbulence possible:

FMU41/FDU91

Fast filling and discharging rate:

FMU90 + FDU9x

Level limit detection:

FMU90 + FDU9x

Continuous / Solids Specifications

Measuring principle Ultrasonic
Characteristic / Application Compact ultrasonic transmitter
Supply / Communication 2-wire HART
Accuracy +/- 2 mm or +/- 0.2 % of set measuring range 1)
Ambient temperature

-40 °C ... 80 °C

(-40 °F ... 176 °F)

Process temperature

-40 °C ... 80 °C

(-40 °F ... 176 °F)

Process pressure / max. overpressure limit

0.7 bar ... 3 bar abs

(10 psi ... 44 psi)

Main wetted parts

PVDF

Process connection G / NPT 1 1/2"
Blocking distance 0.25 m (0.8 ft)
Max. measurement distance

Liquids: 5 m (16 ft),

Solids: 2 m (6.6 ft)

Communication 4...20 mA HART
Certificates / Approvals ATEX, FM, CSA, TIIS, INMETRO, NEPSI
Application limits Take notice of range diagram

Point Level / Liquids Specifications

 

Measuring principle Ultrasonic Limit
Characteristic / Application Compact ultrasonic transmitter
Supply / Communication 2-wire HART
Ambient temperature

-40 °C...+80 °C

(-40 °F...+176 °F)

Process temperature

-40 °C...+80 °C

(-40 °F...+176 °F)

Process pressure / max. overpressure limit

0.7 bar...3 bar abs

(10 psi...44 psi)

Main wetted parts PVDF
Process connection G / NPT 1 1/2"
Blocking distance 0.25 m (0.8 ft)
Communication 4...20 mA HART
Certificates / Approvals ATEX, FM, CSA, INMETRO, NEPSI
Application limits Take notice of range diagram

Point Level / Solids Specifications

Measuring principle

Ultrasonic Limit

Characteristic / Application Compact ultrasonic transmitter
Supply / Communication 2-wire HART
Ambient temperature

-40 °C...+80 °C

(-40 °F...+176 °F)

Process temperature

-40 °C...+80 °C

(-40 °F...+176 °F)

Process pressure / max. overpressure limit

0.7 bar...3 bar abs

(10 psi...44 psi)

Main wetted parts PVDF
Process connection

G / NPT 1 1/2"

Blocking distance 0.25 m (0.8 ft)
Communication 4...20 mA HART
Certificates / Approvals ATEX, FM, CSA, INMETRO, NEPSI
Application limits Take notice of range diagram

Liquids Specifications

 

Measuring principle Ultrasonic
Product headline

Compact ultrasonic measuring instrument

Cost effective solution for open channel

 Max. measurement error  Low accuracy
Measuring range

0,25...5m [0.8...16ft]

 Max. process pressure  atm.
 Medium temperature range  -40°C ... 80°C

(-40°F...176°F)

 Degree of protection  IP68
 Outputs  4...20mA(Hart),PA,FF
 Inputs  2-wire 16-36V DC,

4-wire 16-36V DC,

90-253V AC 50/60Hz

 Digital communication  PROFIBUS PA, FOUNDATION Fieldbus
 Hazardous area approvals  ATEX, FM, CSA

 

Documents

You may want to read this product's catalog. If so, please click to view the Endress+Hauser Ultrasonic measurement Time of Flight Prosonic FMU40 Series datasheet.