Endress+Hauser
Cost-effective Wafer Flowmeter Proline Prowirl D 200
- SKU:
- Proline Prowirl D 200 series
- Weight:
- 0.00 Grams
Description
Application
The Prowirl D sensor can be installed directly between flanges, serving as an effective solution for ancillary processes at minimal installation cost. Utilizing genuine loop-powered technology, the Prowirl D 200 enables cost-effective and seamless integration into existing infrastructures. It ensures maximum operational safety in hazardous environments, while Heartbeat Technology guarantees continuous process safety.
Preferred for measuring wet, saturated, and superheated steam, as well as gases and liquids (including cryogenic applications).
Suitable for all basic applications and for 1-to-1 replacement of orifice plates.
Device properties:
- Face-to-face length of 65 mm (2.56 in)
- No flanges required
- Low weight
- Display module with data transfer function
- Robust dual-compartment housing
- Plant safety: worldwide certifications (SIL, hazardous area)
Benefits
- Integrated temperature measurement for mass/energy flow of saturated steam
- Easy sensor alignment with included centering rings
- High reliability with proven robustness and resistance to vibrations, temperature shocks, and water hammer
- Long-term stability with a robust, drift-free capacitive sensor
- Convenient device wiring with a separate connection compartment
- Safe operation, with no need to open the device due to the display with touch control and background lighting
- Integrated verification with Heartbeat Technology
SPECIFICATIONS
Liquids Specifications
Measuring principle
|
Vortex |
Product headline
|
Cost-effective wafer flowmeter, available as compact or remote version. Integrated temperature measurement for mass/energy flow of saturated steam. For all basic applications and for 1-to-1 replacement of orifice plates.
|
Sensor features
|
Easy alignment of the sensor – included centering rings. High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer. Long-term stability – robust drift-free capacitive sensor. Face-to-face length of 65 mm (2.56 in). No flanges. Low weight.
|
Transmitter features
|
Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
|
Nominal diameter range
|
DN 15 to 150 (½ to 6")
|
Wetted materials
|
Measuring tube: 1.4408 (CF3M) DSC sensor: 1.4435 (316/316L)
|
Measured variables
|
Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
|
Max. measurement error
|
Volume flow (liquid): ±0.75 % Volume flow (steam, gas): ±1.00 % Mass flow (liquid): ±0.85% Mass flow (steam, gas): ±1.7 %
|
Measuring range
|
Liquid: 0.16 to 625 m³/h (0.09 to 368 ft³/min) depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) Steam, gas: 2 to 8342 m³/h (1.18 to 4910 ft³/min) depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
|
Max. process pressure
|
PN 40, Class 300, 20K
|
Medium temperature range
|
Standard: –40 to +260 °C (–40 to +500 °F) High/low temperature (option): –200 to +400 °C (–328 to +752 °F) High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)
|
Ambient temperature range
|
Compact version (standard): –40 to +80 °C (–40 to +176 °F) Compact version (option): –50 to +80 °C (–58 to +176 °F) Remote version (standard): –40 to +85 °C (–40 to +185 °F) Remote version (option): –50 to +85 °C (–58 to +185 °F)
|
Sensor housing material
|
Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)
|
Transmitter housing material
|
AlSi10Mg, coated; 1.4404 (316L)
|
Degree of protection
|
Compact version: IP66/67, type 4X enclosure Sensor remote version: IP66/67, type 4X enclosure Transmitter remote version: IP66/67, type 4X enclosure
|
Display/Operation
|
4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available
|
Outputs
|
4‐20 mA HART (passive) 4‐20 mA (passive) Pulse/frequency/switch output (passive)
|
Inputs
|
Current input 4‐20 mA (passive)
|
Digital communication
|
HART, PROFIBUS PA, FOUNDATION Fieldbus
|
Power supply
|
DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output) DC 12 to 30 V (4‐20 mA HART, 4‐20 mA) DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input) DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)
|
Hazardous area approvals
|
ATEX, IECEx, cCSAus, JPN, EAC, UK Ex
|
Product safety
|
CE, C-TICK, EAC
|
Functional safety
|
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates
|
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
|
Marine approvals and certificates
|
ABS, LR, BV, DNV
|
Pressure approvals and certificates
|
PED, CRN
|
Material certificates
|
3.1 material NACE MR0175/MR0103, PMI (on request)
|
Steam Specifications
Measuring principle
|
Vortex |
Product headline
|
Cost-effective wafer flowmeter, available as compact or remote version. Integrated temperature measurement for mass/energy flow of saturated steam. For all basic applications and for 1-to-1 replacement of orifice plates.
|
Sensor features
|
Easy alignment of the sensor – included centering rings. High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer. Long-term stability – robust drift-free capacitive sensor. Face-to-face length of 65 mm (2.56 in). No flanges. Low weight.
|
Transmitter features
|
Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
|
Nominal diameter range
|
DN 15 to 150 (½ to 6")
|
Wetted materials
|
Measuring tube: 1.4408 (CF3M) DSC sensor: 1.4435 (316/316L)
|
Measured variables
|
Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
|
Max. measurement error
|
Volume flow (liquid): ±0.75 % Volume flow (steam, gas): ±1.00 % Mass flow (liquid): ±0.85% Mass flow (steam, gas): ±1.7 %
|
Measuring range
|
Liquid: 0.16 to 625 m³/h (0.09 to 368 ft³/min) depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) Steam, gas: 2 to 8342 m³/h (1.18 to 4910 ft³/min) depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
|
Max. process pressure
|
PN 40, Class 300, 20K
|
Medium temperature range
|
Standard: –40 to +260 °C (–40 to +500 °F) High/low temperature (option): –200 to +400 °C (–328 to +752 °F) High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)
|
Ambient temperature range
|
Compact version (standard): –40 to +80 °C (–40 to +176 °F) Compact version (option): –50 to +80 °C (–58 to +176 °F) Remote version (standard): –40 to +85 °C (–40 to +185 °F) Remote version (option): –50 to +85 °C (–58 to +185 °F)
|
Sensor housing material
|
Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)
|
Transmitter housing material
|
AlSi10Mg, coated; 1.4404 (316L)
|
Degree of protection
|
Compact version: IP66/67, type 4X enclosure Sensor remote version: IP66/67, type 4X enclosure Transmitter remote version: IP66/67, type 4X enclosure
|
Display/Operation
|
4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available
|
Outputs
|
4‐20 mA HART (passive) 4‐20 mA (passive) Pulse/frequency/switch output (passive)
|
Inputs |
Current input 4‐20 mA (passive)
|
Digital communication
|
HART, PROFIBUS PA, FOUNDATION Fieldbus
|
Power supply
|
DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output) DC 12 to 30 V (4‐20 mA HART, 4‐20 mA) DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input) DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)
|
Hazardous area approvals
|
ATEX, IECEx, cCSAus, JPN, EAC, UK Ex
|
Product safety
|
CE, C-TICK, EAC
|
Functional safety
|
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates
|
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
|
Marine approvals and certificates
|
ABS, LR, BV, DNV
|
Pressure approvals and certificates
|
PED, CRN
|
Material certificates
|
3.1 material NACE MR0175/MR0103, PMI (on request)
|
Gas Specifications
Measuring principle
|
Vortex |
Product headline
|
Cost-effective wafer flowmeter, available as compact or remote version. Integrated temperature measurement for mass/energy flow of saturated steam. For all basic applications and for 1-to-1 replacement of orifice plates.
|
Sensor features
|
Easy alignment of the sensor – included centering rings. High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer. Long-term stability – robust drift-free capacitive sensor. Face-to-face length of 65 mm (2.56 in). No flanges. Low weight.
|
Transmitter features
|
Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
|
Nominal diameter range
|
DN 15 to 150 (½ to 6")
|
Wetted materials
|
Measuring tube: 1.4408 (CF3M) DSC sensor: 1.4435 (316/316L)
|
Measured variables
|
Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
|
Max. measurement error
|
Volume flow (liquid): ±0.75 % Volume flow (steam, gas): ±1.00 % Mass flow (liquid): ±0.85% Mass flow (steam, gas): ±1.7 %
|
Measuring range
|
Liquid: 0.16 to 625 m³/h (0.09 to 368 ft³/min) depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) Steam, gas: 2 to 8342 m³/h (1.18 to 4910 ft³/min) depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
|
Max. process pressure
|
PN 40, Class 300, 20K
|
Medium temperature range
|
Standard: –40 to +260 °C (–40 to +500 °F) High/low temperature (option): –200 to +400 °C (–328 to +752 °F) High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)
|
Ambient temperature range
|
Compact version (standard): –40 to +80 °C (–40 to +176 °F) Compact version (option): –50 to +80 °C (–58 to +176 °F) Remote version (standard): –40 to +85 °C (–40 to +185 °F) Remote version (option): –50 to +85 °C (–58 to +185 °F)
|
Sensor housing material
|
Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)
|
Transmitter housing material
|
AlSi10Mg, coated; 1.4404 (316L)
|
Degree of protection
|
Compact version: IP66/67, type 4X enclosure Sensor remote version: IP66/67, type 4X enclosure Transmitter remote version: IP66/67, type 4X enclosure
|
Display/Operation
|
4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available
|
Outputs |
4‐20 mA HART (passive) 4‐20 mA (passive) Pulse/frequency/switch output (passive)
|
Inputs
|
Current input 4‐20 mA (passive)
|
Digital communication
|
HART, PROFIBUS PA, FOUNDATION Fieldbus
|
Power supply
|
DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output) DC 12 to 30 V (4‐20 mA HART, 4‐20 mA) DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input) DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)
|
Hazardous area approvals
|
ATEX, IECEx, cCSAus, JPN, EAC, UK Ex
|
Product safety
|
CE, C-TICK, EAC
|
Functional safety
|
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates
|
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
|
Marine approvals and certificates
|
ABS, LR, BV, DNV
|
Pressure approvals and certificates
|
PED, CRN
|
Material certificates
|
3.1 material NACE MR0175/MR0103, PMI (on request)
|
Documents
You may want to read this product's catalog. If so, please click to view the Endress+Hauser Proline Prowirl D 200 series datasheet.