Application

The measurement of demineralized water in utilities, such as boiler condensate return lines, requires reliable devices. The Prosonic Flow E 100 provides economical and precise bidirectional flow measurement for all industries. With its integrated temperature measurement, it serves as a multivariable flowmeter, adding significant value to your plant. Heartbeat Technology enhances measurement reliability and extends recalibration intervals. The measurement principle operates independently of pressure, density, temperature, and conductivity. Key applications include bidirectional measurement of demineralized water in utilities, such as boiler condensate return lines.

Device Properties:

  • Accuracy: Up to ±0.5% for flow, or per EN 1434 Cl. 2; ±2.0 °C (±3.6 °F) for temperature
  • Process temperatures: Up to 150 °C (302 °F)
  • Entire meter housing made of stainless steel
  • Output: 4-20 mA HART, pulse/frequency
  • Local display for reading and monitoring
  • Robust transmitter housing

Benefits

  • Long-term stability: Reliable, robust sensor ensures consistent performance.
  • Reduced need for additional measuring points: Multivariable device for multiple parameters.
  • Dependable flow measurement: High turndown ratio of 200:1.
  • Time-saving local operation: Integrated web server allows configuration without extra software or hardware.
  • Extended calibration intervals: Integrated device verification with Heartbeat Technology.
  • Easy commissioning: Quick parameter explanations simplify setup

SPECIFICATIONS

Liquids Specifications

 

Measuring principle

 

 


Ultrasonic flow

 

Product headline

 

 

Economical Ultrasonic flowmeter with integrated temperature measurement.

Bidirectional measuring of demineralized water applications for Utilities, e.g. boiler condensate return lines.

 

 

Sensor features

 

 

Long-term stability – reliable, robust sensor. Reducing further measuring point – multivariable device. Dependable flow measurement – high turndown (200:1).

Measurement accuracy up to ±0.5 % (flow) or according to EN 1434 Cl. 2, ±2.0 °C (± 3.6 °F) (temperature). Process temperatures up to 150 °C (302 °F). Entire meter housing made of stainless steel.

 

 

Transmitter features

 

 

Time-saving local operation without additional software and hardware – integrated web server. Extended calibration intervals – integrated device verification due to Heartbeat Technology. Easy commissioning – brief parameter explanations.

4-20 mA HART, pulse/frequency output. Local display for reading and monitoring available. Robust transmitter housing.

 

 

Nominal diameter range

 

 

DN 50 to 150 (2"to 6")

 

 

Wetted materials

 

 

Measuring tube: 1.4301 (F304)

Process Connection: 1.4571; 1.4404 (F316L); 1.0038 (S235JR); 1,4306 (F304L); 1.4307 (F304L); A105

 

 

Measured variables

 

 

Volume flow, calculated mass flow, flow velocity, sound velocity, temperature

 

 

Max. measurement error

 

 

Volume flow:

- ± 0.5 % o.r. ± 0.02% o.f.s. for 0.5 to 10 m/s (1.6 to 33 ft/s)

- ± 0.07 % o.f.s. for flow velocities < 0.5 m/s (1.64 ft/s)

 

 

Measuring range

 

 

0.025 to 5 m/s (0.02 to 16.4 ft/s)

0 to 6360 dm3/min (0 to 1680 gal/min)

 

 

Max. process pressure

 

 

PN 25 / ASME Cl. 150

 

 

Medium temperature range

 

 

0 to 150° (17.8 to 302 °F)

 

 

Ambient temperature range

 

 

-20 to 60 °C (-4 to 140 °F)

 

 

Sensor housing material

 

 

Stainless steel

 

 

Transmitter housing material

 

 

Compact:

AlSi10Mg, coated

Stainless steel, 1.4301

 

 

Degree of protection

 

 

Standard: IP66/67, Type 4X enclosure

With opened housing: IP20, Type 1 enclosure

 

 

Display/Operation

 

 

4‐line backlit display available (no local operation)

Configuration via web browser and operating tools possible

 

 

Outputs

 

 

4‐20 mA HART (active)

Pulse/frequency/switch output (passive)

 

 

Inputs

 

 

None

 

 

Power supply

 

 

DC 19.2 to 28.8 V

 

 

Hazardous area approvals

 

 

None

 

Product safety

 

CE, C-Tick, EAC marking

 

 

Metrological approvals and certificates

 

 

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)

Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

Calibration according to EN 1434 Class 2

 

 

Pressure approvals and certificates

 

 

PED

 

Material certificates

 

3.1 material

 

 

Documents