The Deltabar PMD55 differential pressure transmitter, equipped with a piezoresistive sensor and a welded metallic membrane, is ideal for continuous pressure difference measurement in liquids, vapors, and gases within various process and environmental applications. Its Quick Setup feature with an adjustable measuring range ensures easy commissioning, reducing time and cost. It complies with SIL2 standards as per IEC 61508 / IEC 61511.

It is suitable for level, volume, or mass measurement in liquids, differential pressure monitoring (e.g., for filters and pumps), and flow measurement (both volume and mass flow) when used with primary elements in gases, vapors, and liquids.

  • Process connections: Threads
  • Process temperature: -40 to 85°C (-40 to 185°F)
  • Measuring ranges: 0.5 mbar to 40 bar (0.0072 to 600 psi)
  • Accuracy: ±0.1%, with an optional "Platinum" accuracy of ±0.075%
  • Certifications: International explosion protection certificates and SIL compliance

 


Benefits

  • Simple Commissioning: User-friendly menu-guided setup via local display, supporting 4 to 20mA with HART, PROFIBUS PA, and FOUNDATION Fieldbus.
  • Easy Process Adaptation: Quick adjustment of impulse lines for high- or low-pressure changes using an electric switch on the main electronics.
  • Modular and Compact Design: Compact structure with a modular design for easy replacement of the display or electronics components.
  • Certified for Process Safety: Supports process pressures up to SIL2, certified according to IEC 61508 and IEC 61511.

Global Applicability: Approved for a wide range of industries and applications worldwide.

 

SPECIFICATIONS

Pressure Specifications

Measuring principle Differential pressure
Product headline

Digital transmitter with metallic measuring diaphragms

Compact size

Modular transmitter

Long-term stability

Max. measurement error

0,1%

"PLATINUM" 0,075%

Max. process pressure

10mbar...40bar

(0.15...580psi)

Medium temperature range Temperature gradient from pressure piping
Display/Operation

Option


Outputs

4...20mA HART

 

Digital communication HART
Hazardous area approvals ATEX, FM, CSA, IECEx, INMETRO, NEPSI, TIIS
Functional safety SIL
Material certificates

NACE MR0103

NACE MR0175

EN10204-3.1

 

Pressure Specifications

Measuring principle Differential pressure
Characteristic

Digital transmitter with metallic measuring diaphragms

Compact size

Modular transmitter

Long-term stability

Supply voltage

4...20 mA HART

11,5...45V DC (Non Ex):

Ex ia: 11,5...30V DC

PROFIBUS PA:

9...32 V DC (Non Ex)

FOUNDATION Fieldbus:

9...32 V DC (Non Ex)

Reference Accuracy

Standard 0.1%

Platinum 0.075%

Long term stability

0.05% of URL/ year

0.13% of URL/ 5 years

0.23% of URL/ 10 years

Process temperature

-40°C...+85°C

(-40°F...+185°F)

Ambient temperature

-40°C...+85°C

(-40°F...+185°F)

Measuring cell

10 mbar...40 bar

(0.15...580 psi)

Smallest calibratable span

10 mbar (0.15 psi)

Max. Turn down 20:1

Max. overpressure limit

on one side:

160 bar

(2300 psi)

Process connection 1/4-18 NPT
Material process membrane 316L, AlloyC,

Material gasket

Viton, PTFE, EPDM, NBR
Fill fluid

Silicone oil

Inert oil

Material housing Die-cast aluminum

Communication

4...20 mA HART

PROFIBUS PA

FOUNDATION Fieldbus

Certificates / Approvals

ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex

Safety approvals SIL
Design approvals

NACE MR0175

EN10204-3.1

Successor PMD55B

Gas Specifications

Measuring principle Differential pressure
Product headline

Digital transmitter with metallic measuring diaphragms

Compact size

Modular transmitter

Long-term stability

Max. measurement error

0,1%

"PLATINUM" 0,075%

Max. process pressure

10mbar...40bar

(0.15...580psi)

Medium temperature range Temperature gradient from pressure piping
Display/Operation Option
Outputs 4...20mA HART
Digital communication HART
Hazardous area approvals ATEX, FM, CSA, IECEx, INMETRO, NEPSI, TIIS

Functional safety

SIL
Material certificates

NACE MR0103

NACE MR0175

EN10204-3.1

Continuous / Liquids Specifications

Measuring principle Differential pressure
Characteristic / Application

Digital transmitter with metallic measuring diaphragms

Compact size

Modular transmitter

Long-term stability

Supply / Communication

4...20mA HART:

11,5...45V DC

Ex ia: 11,5...30V DC

Accuracy

0,1%

"PLATINUM" 0,075%

Long term stability

0,05% of URL/year

0,125% of URL/5 years

Ambient temperature

-40°C...85°C

(-40°F...185°F)

Process temperature

-40 °C...85 °C

(-40 °F...185 °F)

Process pressure / max. overpressure limit

160 bar

Pressure measuring range

10mbar...40bar

(0.15...580psi)

Main wetted parts 316L
Process connection 1/4-18 NPT
Communication

4...20mA HART

PROFIBUS PA

FOUNDATION Fieldbus

Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI
Safety approvals SIL
Design approvals

EN 10204-3.1

NACE MR0175, MR0103

AD2000

Options

4-line digital display

Aluminium housing

Successor PMD55B
Application limits

Measuring cell:

Metal welded

Liquids Specifications

 

Measuring principle Differential pressure
Product headline

Digital transmitter with metallic measuring diaphragms

Compact size

Modular transmitter

Long-term stability

Max. measurement error

0,1%

"PLATINUM" 0,075%

Max. process pressure

10 mbar...40 bar

(0.15...580 psi)

Medium temperature range

Temperature gradient from pressure piping

Display/Operation Option
Outputs 4...20mA HART

Digital communication

HART
Hazardous area approvals ATEX, FM, CSA, IECEx, INMETRO, NEPSI, TIIS
Functional safety SIL
Material certificates

NACE MR0103

NACE MR0175

EN10204-3.1

 

Documents

You may want to read this product's catalog. If so, please click to view the Endress+Hauser Differential pressure Deltabar PMD55 Series datasheet.
View AllClose