Endress+Hauser
Differential pressure Deltabar PMD75
- SKU:
- Differential pressure Deltabar PMD75 series
- Weight:
- 0.00 Grams
Description
Application
The Deltabar PMD75 differential pressure transmitter, equipped with a piezoresistive sensor and welded metallic membrane, is designed for continuous measurement in liquids, gases, and vapors across a wide range of industries. Its 3-button interface ensures straightforward and dependable setup and operation. The built-in HistoROM data module simplifies the management of both process and device parameters. Engineered in compliance with IEC 61508, it is suitable for SIL2/3 safety applications.
It is ideal for level, volume, or mass measurement in liquids, differential pressure monitoring, as well as flow measurement (either volume or mass flow) when used in combination with primary elements in gases, vapors, and liquids.
- Process connections: Threaded
- Process temperature range: -40 to +85°C (-40 to +185°F)
- Measuring range: 0.25 mbar to 40 bar (0.0036 to 600 psi)
- Accuracy: ±0.05%, with optional "Platinum" accuracy of ±0.035%
- Certifications: International explosion protection, WHG overfill prevention, SIL, hygienic, and marine approvals
Benefits
- Superior accuracy, reproducibility, and long-term stability
- Maximum safety with gas-tight feedthroughs supporting SIL2/3 compliance, certified to IEC 61508
- Intuitive, menu-driven commissioning via local display, supporting 4 to 20mA with HART, PROFIBUS PA, and FOUNDATION Fieldbus
- HistoROM data management system streamlines commissioning, maintenance, and diagnostics
- Cost-efficient modular design for easy replacement of sensors, displays, or electronics
- Overload protection up to 420 bar / 42 MPa / 6300 psi with continuous function monitoring
- Seamless system integration across HART, PROFIBUS PA, and FOUNDATION Fieldbus
SPECIFICATIONS
Pressure Specifications
Measuring principle
|
Differential pressure
|
Characteristic |
Digital transmitter with metallic measuring diaphragms Modular transmitter Long-term stability High static pressure/Overload resistance Secondary process barrie
|
Supply voltage
|
4...20 mA HART 10,5...45V DC (Non Ex): Ex ia: 10,5...30V DC PROFIBUS PA: 9...32 V DC (Non Ex) FOUNDATION Fieldbus: 9...32 V DC (Non Ex)
|
Reference Accuracy
|
Standard: 0.05% Platinum: up to 0.035%
|
Long term stability
|
0.03 % of URL/ year 0.05 % of URL/ 5 years 0.08 % of URL/ 10 years
|
Process temperature
|
-40°C...85°C (-40°F...185°F)
|
Ambient temperature
|
-50°C...85°C (-58°F...185°F)
|
Measuring cell
|
10 mbar...250 bar (0.15 psi...3750 psi)
|
Smallest calibratable span
|
1 mbar (0.015 psi)
|
Vacuum resistance
|
50 mbar (0.73 psi)
|
Max. Turn down
|
100:1
|
Max. overpressure limit
|
On one side: 420 bar (6300psi)
|
Process connection
|
1/4-18NPT RC1/4"
|
Material process membrane
|
316L, AlloyC, Tantal, Gold-Rhodium
|
Material gasket
|
Viton, PTFE, EPDM, NBR
|
Fill fluid
|
Silicone oil Inert oil
|
Material housing
|
316L, Die-cast aluminum |
Communication
|
4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus
|
Certificates / Approvals
|
ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC, UK Ex
|
Safety approvals
|
SIL
|
Design approvals
|
NACE MR0103 EN10204-3.1
|
Marine approvals
|
GL/ ABS
|
Specialities
|
Diagnostic functions
|
Successor | PMD75B |
Continuous / Liquids Specifications
Measuring principle
|
Differential pressure
|
Characteristic / Application
|
Digital transmitter with metallic measuring diaphragms Modular transmitter Long term stability High static pressure/Overload resistance Enhanced safety via self diagnostic functions Secondary process barrier
|
Supply / Communication
|
4...20 mA HART: 10,5...45V DC Ex ia: 10,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC
|
Accuracy
|
Standard: 0.05% Platinum: up to 0.035%
|
Long term stability
|
0,05% of URL/year
|
Ambient temperature
|
-50 °C...85 °C (-58 °F...185 °F)
|
Process temperature
|
-40 °C...85 °C (-40 °F...185 °F)
|
Process pressure / max. overpressure limit
|
420 bar (6300 psi)
|
Pressure measuring range
|
10 mbar...250 bar (0.15 psi...3750 psi)
|
Main wetted parts
|
Alloy C276 316L Monel Tantalum
|
Process connection
|
1/4-18NPT RC1/4"
|
Max. measurement distance
|
400 m (1.312 ft) H2O
|
Communication
|
4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus
|
Certificates / Approvals
|
ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC
|
Safety approvals
|
SIL
|
Design approvals
|
EN 10204-3.1 NACE MR0175, MR0103
|
Marine approval
|
GL/ ABS
|
Options
|
HistoROM/M-Dat 4-line digital display SS- or Aluminiumhousing Separate housing
|
Successor
|
PMD75B
|
Application limits
|
Measuring cell: Metal welded
|
Liquids Specifications
Measuring principle
|
Differential pressure
|
Product headline
|
Digital transmitter with metallic measuring diaphragms Modular transmitter Long-term stability High static pressure/Overload resistance Enhanced safety via self diagnostic functions Secondary process barrier
|
Max. measurement error
|
0,075% "PLATINUM" 0,05%
|
Max. process pressure
|
max. 420 bar (max. 6091 psi)
|
Medium temperature range
|
Temperature gradient from pressure piping
|
Display/Operation
|
Option
|
Outputs
|
4...20mA HART PROFIBUS PA FOUNDATION Fieldbus
|
Digital communication
|
HART PROFIBUS PA FOUNDATION Fieldbus
|
Hazardous area approvals
|
ATEX, FM, CSA, IECEx, INMETRO, NEPSI, TIIS
|
Functional safety
|
SIL
|
Material certificates
|
NACE MR0103 NACE MR0175 EN10204-3.1
|
Gas Specifications
Measuring principle
|
Differential pressure
|
Product headline
|
Digital transmitter with metallic measuring diaphragms Modular transmitter Long-term stability High static pressure/Overload resistance Enhanced safety via self diagnostic functions Secondary process barrier
|
Max. measurement error
|
0,075% "PLATINUM" 0,05%
|
Max. process pressure
|
max. 420 bar (max. 6 091 psi)
|
Medium temperature range
|
Temperature gradient from pressure piping
|
Display/Operation
|
Option
|
Outputs |
4...20mA HART PROFIBUS PA FOUNDATION Fieldbus
|
Digital communication
|
HART PROFIBUS PA FOUNDATION Fieldbus
|
Hazardous area approvals
|
ATEX, FM, CSA, IECEx, INMETRO, NEPSI, TIIS
|
Functional safety
|
SIL
|
Material certificates
|
NACE MR0103 NACE MR0175 EN10204-3.1
|
Documents
You may want to read this product's catalog. If so, please click to view the Endress+Hauser Deltabar PMD75 Series datasheet.