Tecpel
Digital Clamp Meter, 57mm jaw opening capability - DCM-2608
- SKU:
- DCM-2608
- MPN:
- DCM-2608
- Weight:
- 540.00 Grams
- Minimum Purchase:
- 1 unit
Description
Tecpel Digital Clamp meters 1000A AC/DC Amp +Frequency - DCM-2608
Capacitance measurement, Over range indication, Graphic Display – Accurate and Reliable
In electrical and electronic engineering, a current clamp or current probe is an electrical device with jaws that open to allow clamping around an electrical conductor. This allows the measurement of the current in a conductor without the need to make physical contact with it or to disconnect it for insertion through the probe.
DCM-2608 from Tecpel is a digital 1000A AC/DC Amp +Frequency clamp meter.
Tecpel Digital Clamp meters DCM-2608 features
- 3 3/4 digit display (4000 Counts)
- AC current up to 1500A; DC current up to 2000A
- AC voltage up to 750V; DC voltage up to 1000V
- Resistance up to 40MΩ
- Frequency up to 400kHz
- Capacitance measurement
- Audible continuity test / Diode test
- Over range indication
- Max/Min recording mode
- Relative mode to read offset values (Zero Key)
- Peak hold for transient measurement
- Confirm to the IEC-1010-1, UL1244/UL3111, CE standard
- CAT III, AC 750V, DC 1000V
- Hand guard protection
- Soft Carrying case.
Tecpel Digital Clamp meters DCM-2608 specification:
- DC Voltage Ranges: 400mV,4V,40V,400V,1000V, ±(0.5%+1dgt)
- AC Voltage Ranges: 400mV,4V,40V,400V,750V, ±(1.5%+4dgts)
- AC Current Ranges: 200A,1500A, ±(1.5~5%+5dgts)
- DC Current Ranges: 200A,1000A, ±(1.5~5%+5dgts)
- Resistance Ranges: 400Ω,4kΩ,40kΩ,400kΩ,4000kΩ,40MΩ, ±(1.0%+4dgts)
- Continuity Test: Audible indication
- Polarity: Automatic (-) negative polarity indication.
- Over range indication: MSD (Most Significant Digit) blinks.
- Lower Battery indication: the ""battery sign"" is displayed when the battery voltage drops below accurate operating level.
- Measurement rate: 2/sec. nominal 1/sec. Capacitance and Frequency mode. 20/sec. Analog display.
- Operating Environment: 0 °C to 50 °C at < 70% RH
- Storage Environment: -20 °C to 60 °C at 80% RH
- Temperature Coefficient: 0.1 x (specified accuracy)/ °C (< 18 °C or > 28 °C)
- Auto Power Off: 30 minutes after rotary switch or mode changes.
- Altitude 6561.7 Feet (2000M)
- Power: One standard 9-Volt battery, NEDA 1604, IEC 6f22, jis 006P
- Battery Life: 100 Hours typical with alkaline battery.
- Jaw Opening Capacity: 57 mm conductor, 70 x 18 mm bus bar.
- Weight: Approx. 18.9 OZ/ 540 g grams (including battery).
- Dimensions: 10.9""x4.0""x1.9"" (277x102x49mm)
- Accessories: Test leads; soft carrying case, battery, and owner’s manual
Brand Information
Tecpel Co. Ltd. has over 20 years of experience in the Test and Measurement market. They have set up over 50 country distributors worldwide. Some of their products have been branded by famous leaders in the market. About 60% of their customers are repeat customers. Tecpel imports products from Japan and carries out quality checks. Their products are exported to Europe mainly. If customers find a fault with the product, they will replace it with a new product within 2-3 days.
They are regarded as one of the leading Taiwanese manufactures of high quality test and measurements. Their product lines include power supplies, oscilloscopes, electronics & electrical meters and testers. Tecpel’s quality products have been accepted by some well-known international customers. The confidence they have in their products is reflected in their one-year warranty and by their flat-rate service policy through 3-5 years.
Data Sheet
To View Data Sheet for Digital Clamp meters 1000A AC/DC Amp +Frequency - DCM-2608 Please Click HereAdditional Information
Display: |
3 3/4 digit (4000 counts), 9999 counts (Frequency Mode), 42 segment Analog bar graph and function/units sign annunciators. |
DC Voltage Ranges: |
400mV, 4V, 40V, 400V, 1000V, ± (0.5%+1dgt). |
AC Voltage Ranges: |
400mV, 4V, 40V, 400V, 750V, ± (1.5%+4dgts). |
AC Current Ranges: |
200A, 1500A, ± (1.5~5%+5dgts). |
DC Current Ranges: |
200A, 1000A, ± (1.5~5%+5dgts). |
Resistance Ranges: |
400Ω, 4kΩ, 40kΩ, 400kΩ, 4000kΩ, 40MΩ, ± (1.0%+4dgts). |
Polarity: |
Automatic (-) negative polarity indication. |
Overrange indication: |
MSD (Most Significant Digit) blinks. |
Lower Battery indication: |
The "battery sign" is displayed when the battery voltage drops below accurate operating level. |
Measurement rate: |
2/sec. nominal 1/sec. Capacitance and Frequency mode. 20/sec. Analog display. |
Storage Environment: |
-20 °C to 60 °C at 80% RH. |
Temperature Coefficient: |
0.1 x (specified accuracy)/ °C ( < 18 °C or > 28 °C). |
Auto Power Off: |
30 minutes after rotary switch or mode changes. |
Altitude: |
6561.7 Feet (2000M). |
Power and Battery Life: |
One standard 9-Volt battery, NEDA 1604, IEC 6f22, jis 006P. 100 Hours typical with alkaline battery. |
Jaw Opening Capacity: |
57 mm conductor, 70 x 18 mm bus bar. |
Weight: |
Approx. 18.9 OZ/ 540 g (including battery). |
Dimensions: |
10.9""x4.0""x1.9"" (277x102x49mm). |
Accessories: |
Test leads; soft carrying case, battery, and owner’s manual. |