Autonics Multi Pulse Meter - MP5W-44

5-digit 7-segment LED, -19999 to 99999 display Range

 

As a quick report, this panel meter provides:

  • Display method: 5-digit 7-segment LED
  • Character height: 14 mm
  • Max. display Range: -19999 to 99999
  • 16 operation modes: Frequency, Revolutions, Speed, Cycle, Time, Ratio, Density, Error, Length measurement, Interval, Accumulation, Addition/Subtraction, etc.
  • Measurement range: 0.0005Hz to 50kHz, 0.01 to max. of each time range, 0 to 99999, -19999 to 99999
  • Input method: Voltage input (PNP), No-voltage input (NPN)
  • Power supply: 100-240 VAC ~ 50/60 Hz
  • Output_Main Output (Comparative Value): NPN open collector (HH, H, GO, L, LL)
  • Output_Sub Output (Display Value): PV transmission (DC0-20mA, DC4-20mA)
  • DIN W 96 × H 48

Temperature

There are limitations in temperature and humidity in which MP5W-44 panel meter is used:

  • Storage temperature: -20 … 60°C
  • Storage humidity: 35 to 85%RH
  • Ambient temperature: -10 … 50°C
  • Ambient humidity: 35 to 85%RH

Environment resistance is rated at no freezing or condensation.

Industries / applications

  • Rubber Extrusion / Plastic Injection Molding Process
  • Frame Assembly: measure the movement speed of car frames on conveyor belts during assembly process.

 

Click on the following link to view other Autonics Digital Panel Meter series.

Series Information

MP5S/MP5Y/MP5W Series

High Performance Digital Pulse Meters

The Autonics MP5S/MP5Y/MP5W series high performance digital pulse meters can display various values using pulse inputs including rotation speed, speed, frequency, and more with 16 different operation modes. The meters can be applied in various industrial applications for accurate measurement and clear readings.

*Select features of the MP5S/MP5Y/MP5W series have been upgraded. Please refer to the specifications table for upgrade details.

MP5S/MP5Y/MP5W Series Main features

  • 16 operation modes
          - Frequency / revolutions/speed, passing speed, cycle, passing time, time interval, time differential, absolute ratio, error ratio, density, error, length measurement 1, length measurement 2, interval, accumulation, addition/subtraction (individual input), addition/subtraction (phase difference input)
  • Various output options

          - Relay triple / quintuple output, NPN / PNP open collector quintuple output, BCD dynamic output, PV transmission output (current output), RS485 communication output

  • Various functions

          - Prescale function, delay monitoring function, hysteresis, auto-zero, parameter lock function, data bank function (MP5W only)

  • NPN input (non-contact / contact) or PNP input (non-contact / contact)
  • Display range: -19999 to 99999
  • Various display units

          - rpm, rps, Hz, kHz, sec, min, m, mm, mm/s, m/s, m/min, m/h, â„“/s, â„“/min, â„“/h, %, counts, etc.

  • Power supply

          - 100-240VAC 50/60Hz (AC type)
          - 24VAC 50/60Hz, 24-48VDC (AC/DC type)

About Autonics Digital Panel Meter

"Autonics" is a leading provider of automation solutions from South Korea. Autonics products are trusted and adopted by engineers in various industrial applications and their technology is widely applied in day-to-day automation devices. This company represents 17 Digital Panel Meter:

  • MX4W Series: LCD Display Multi Panel Meter
  • M4V Series: Digital Panel Meters for Mosaic Panels
  • M4N Series: Compact Digital Panel Meters
  • M4NN Series: Compact Digital Panel Meters with Diverse Input Options
  • MT4Y/MT4W Series: Digital Panel Meters with Diverse Input/Output Options
  • MT4N Series: Compact Digital Panel Meters with Diverse Input/Output Options
  • M4NS/M4YS Series: Loop-Powered Digital Scaling Meters
  • M4Y, M5W, M4W, M4M (Scaling) Series: Digital Scaling Meter
  • M4Y, M5W, M4W, M4M (Voltmeter) Series: Digital Voltmeters
  • M4Y, M5W, M4W, M4M (Wattmeter) Series: Digital Wattmeters
  • M4Y, M5W, M4W, M4M (Ammeter) Series: Digital Ammeters
  • MP5S/MP5Y/MP5W Series: High Performance Digital Pulse Meters
  • MP5M Series: High Performance Digital Pulse Meters (Thumbwheel Switch Type)
  • M4W-P Series: Power Factor Display Digital Panel Meters
  • LR5N-B Series: Compact Digital Pulse Meters (Indicator Only)
  • M4Y, M5W, M4W, M4M (Tachometer / Speed Meter) Series: Digital Tachometers (Speed Meters)

Autonics Digital Panel Meter are mainly used in:

  • Measure and display voltage and current of processes on LCD inspection machines
  • Plastics/Rubber Industry
  • Logistics Industry
  • Measure and display voltage and current of processes on distribution panels
  • Automotive

Documents

You may be interested to see this product's catalog. If so, please click to view the MP5W-44 datasheet.
View AllClose

Warranty Information

One Year Warranty
View AllClose

Additional Information

Display method:
5-digit 7-segment LED
Character height:
14mm
Max. display Range:
-19999 to 99999
Measurement:
16 operation modes: Frequency, Revolutions, Speed, Cycle, Time, Ratio, Density, Error, Length measurement, Interval, Accumulation, Addition/Subtraction, etc.
Measurement range:
0.0005Hz to 50kHz, 0.01 to max. of each time range, 0 to 99999, -19999 to 99999
Input method:
Voltage input(PNP), No-voltage input(NPN)
Power supply:
100-240VAC~ 50/60Hz
External Power Supply:
Max. 12VDC ±10% 80mA
Output_Main Output(Comparative Value):
NPN open collector (HH, H, GO, L, LL)
Output_Sub Output(Display Value):
PV transmission (DC0-20mA, DC4-20mA)
Input frequency:
•Solid state input 1: max. 50kHz (pulse width: min. 10㎲) •Solid state input 2: max. 5kHz (pulse width: min. 100㎲) ※For F7, F8, F9, F10 operation mode, max. 1kHz (pulse width: min. 500㎲) •Contact input: max. 45Hz (pulse width: min. 11ms)
Measurement range:
•Operation mode F1, F2, F7, F8, F9, F10 : 0.0005Hz to 50kHz •Operation mode F3, F4, F5, F6 : 0.01 to max. of each time range •Operation mode F11, F12, F13, F16 : 0 to 99999 •Operation mode F14, F15 : -19999 to 99999
Measurement accuracy:
•Operation mode F1, F2, F7, F8, F9, F10 : F.S.±0.05%rdg±1-digit •Operation mode F3, F4, F5, F6 : F.S.±0.01%rdg±1-digit
Prescale function:
Direct input method (0.0001×10-9 to 9.9999×109)
Environment_Ambient temperature:
-10 to 50℃, storage: -20 to 60℃
Environment_Ambient humidity:
35 to 85% RH, storage: 35 to 85% RH
Unit weigth (package):
≈ 210 g (≈ 334 g)
View AllClose