Application

The Liquiline CM442 transmitter enables connection to up to two Memosens sensors, offering flexibility across more than 12 measurement parameters. With automatic sensor recognition, easy operation, and standardized spare parts across the Liquiline platform, it simplifies maintenance and operation. Equipped with inputs, outputs, controllers, and math modules, the device can also control cleaning systems or dosing pumps. Heartbeat Technology ensures optimal balance between system availability and maintenance costs. The Liquiline CM442 is versatile and can be used in various industries and their utilities, including:

  • Food & Beverage
  • Life Sciences
  • Power & Energy
  • Water & Wastewater
  • Chemical Processing
  • Marine Applications

It supports the following communication protocols and interfaces:

  • 0/4...20 mA
  • HART
  • PROFIBUS DP
  • Modbus RS485/RTU
  • Modbus TCP
  • EtherNet/IP
  • PROFINET
  • Webserver

Additionally, it can be expanded with a module approved for explosion protection standards like IECEx, ATEX, and CSA, allowing safe sensor connections in hazardous areas.


Benefits

Clever Simplicity:A single controller supports all measurement parameters and applications, featuring an intuitive user interface with automatic sensor recognition. The device also offers hot plug-and-play functionality with pre-calibrated Memosens sensors. High Flexibility:Universal modules accommodate all measurement parameters, minimizing spare part inventory. The system can be easily extended to support up to eight channels as needed. Seamless System Integration:A comprehensive range of communication standards ensures compatibility with any distributed control system (DCS). Simple and Safe Commissioning:Configuration can be stored on an SD card, enabling quick setup for duplicate installations. Remote Process Control:An integrated web server allows remote access to diagnostic data, configurations, and device parameters via any web browser, including on smartphones. Increased Availability, Reduced Costs:Heartbeat Technology facilitates status-based maintenance and easy verification of the entire measuring system, supporting process optimization and reducing maintenance costs.

Documents

You may want to read this product's catalog. If so, please click to view the Liquiline CM442 Series datasheet.

SPECIFICATIONS

pH Specification

Measuring principle Potentiometric
Application Modular 4 wire controller
Multichannel: 1/2 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate, and turbidity
Two sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic Robust plastic housing
All non-ex applications
Design 2x Memosens input, 2 to 4x current output, Alarmrelay
2x relay, SD card for software update and copy & paste of setup
Material Housing base: PC-FR
Housing seal: EPDM
Dimension 237 x 194 x 162 mm
9.33 x 7.64 x 6.38 inch
Process temperature -20 to 60 °C (0 to 140 °F)
Ingress protection IP66 / IP67
Input 1 to 2x Memosens digital input
2x 0/4 to 20mA input optional
2x Digital input optional
Output / communication 2 to 8x 0/4 to 20 mA current outputs
Alarmrelay, 2x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet
Additional certifications EAC, cCSAus, MCERTS

ORP Redox Specification

Measuring principle Sensor ORP / Redox
Application Modular 4 wire controller
Multichannel: 1/2 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate, and turbidity
Two sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic Robust plastic housing
All non-ex applications
Design 2x Memosens input, 2 to 4x current output, Alarmrelay
2x relay, SD card for software update and copy & paste of setup
Material Housing base: PC-FR
Housing seal: EPDM
Dimension 237 x 194 x 162 mm
9.33 x 7.64 x 6.38 inch
Process temperature -20 to 60 °C (0 to 140 °F)
Ingress protection IP66 / IP67
Input 1 to 2x Memosens digital input
Output / communication 2 to 8x 0/4 to 20 mA current outputs
Alarmrelay, 2x relay
Additional certifications EAC, cCSAus, MCERTS

Conductivity Specification

Measuring principle Conductive
Application Modular 4 wire controller
Multichannel: 1/2 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate, and turbidity
Two sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic Robust plastic housing
All non-ex applications
Design 2x Memosens input, 2 to 4x current output, Alarmrelay
2x relay, SD card for software update and copy & paste of setup
Material Housing base: PC-FR
Housing seal: EPDM
Dimension 237 x 194 x 162 mm
9.33 x 7.64 x 6.38 inch
Process temperature -20 to 60 °C (0 to 140 °F)
Ingress protection IP66 / IP67
Input 1 to 2x Memosens digital input
Output / communication 2 to 8x 0/4 to 20 mA current outputs
Alarmrelay, 2x relay
Additional certifications EAC, cCSAus, MCERTS

Oxygen Specification

Measuring principle Amperometric oxygen measurement
Application Modular 4 wire controller
Multichannel: 1/2 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate, and turbidity
Two sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic Robust plastic housing
All non-ex applications
Design 2x Memosens input, 2 to 4x current output, Alarmrelay
2x relay, SD card for software update and copy & paste of setup
Material Housing base: PC-FR
Housing seal: EPDM
Dimension 237 x 194 x 162 mm
9.33 x 7.64 x 7.38 inch
Process temperature -20 to 60 °C (0 to 140 °F)
Ingress protection IP67
Input 1 to 2x Memosens digital input
Output / communication 2 to 4x 0/4...20 mA current outputs
Alarmrelay, 2x relay
Additional certifications EAC, cCSAus, MCERTS

Disinfection Specification

Measuring principle Free chlorine
Application Modular 4 wire controller
Multichannel: 1/2 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate, and turbidity
Two sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic Robust plastic housing
All non-ex applications
Design 2x Memosens input, 2 to 4x current output, Alarmrelay
2x relay, SD card for software update and copy & paste of setup
Material Housing base: PC-FR
Housing seal: EPDM
Dimension 237 x 194 x 162 mm
9.33 x 7.64 x 7.38 inch
Process temperature -20 to 60 °C (0 to 140 °F)
Input 1 to 2x Memosens digital input
Output / communication 2 to 4x 0/4 to 20 mA current outputs
Alarmrelay, 2x relay
Additional certifications EAC, cCSAus, MCERTS

Turbidity Specification

Measuring principle Four beam alternating light
Application Modular 4 wire controller
Multichannel: 1/2 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate, and turbidity
Two sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic Robust plastic housing
All non-ex applications
Design 2x Memosens input, 2 to 4x current output, Alarmrelay
2x relay, SD card for software update and copy & paste of setup
Material Housing base: PC-FR
Housing seal: EPDM
Dimension 237 x 194 x 162 mm
9.33 x 7.64 x 7.38 inch
Process temperature -20 to 60 °C (0 to 140 °F)
Ingress protection IP66 / IP67
Input 1 to 2x Memosens digital input
2x 0/4 to 20 mA input (optional)
2x Digital input (optional)
Output / communication 2 to 4x 0/4 to 20 mA current outputs
Alarmrelay, 2x relay
Additional certifications EAC, cCSAus, MCERTS

Concentration Specification

Measuring principle Fluorescence measurement

Analyser Specification

Measuring principle UV photometric
Characteristic Robust plastic housing
All non-ex applications
Design 2x Memosens input, 2 to 4x current output, Alarmrelay
2x relay, SD card for software update and copy & paste of setup
Process temperature -20 to 60 °C (0 to 140 °F)
Application Modular 4 wire controller
Multichannel: 1/2 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
Two sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Output / communication 2 to 8x 0/4 to 20 mA current outputs
Alarmrelay, 2x relay
Input 1 to 2x Memosens digital input
View AllClose