Application

The innovative four-tube design of the Promass X offers exceptional accuracy (0.05%) for high-capacity measurements, delivering superior performance in both onshore and offshore applications within the oil and gas industry. Featuring the compact Promass X 300 transmitter, the device provides operational flexibility and easy system integration, with convenient access from a single side, remote display capabilities, and enhanced connectivity options. Heartbeat Technology ensures reliable measurement and compliance with verification standards.

The measurement principle operates independently of fluid properties like viscosity or density.

Ideal for high flow rates and excellent performance in oil and gas applications, whether onshore or offshore.

Device Features:

  • Nominal diameters: DN 300 to 400 (12" to 16")
  • Four-tube system with minimal pressure drop
  • Full exterior construction of 1.4435 (316L)
  • Compact, dual-compartment housing with up to 3 I/Os
  • Backlit display with touch controls and WLAN access
  • Optional remote display available

Benefits

  • Enhanced profitability – single installation point offering top-tier accuracy for large volume measurements
  • Reduced need for multiple measuring points – multivariable measurement capabilities (flow, density, temperature)
  • Space-efficient installation – no need for inlet/outlet runs
  • Comprehensive process and diagnostic access – multiple configurable I/Os and Ethernet connectivity
  • Simplified operations – customizable I/O functionality reduces complexity
  • Built-in verification – Heartbeat Technology for ongoing measurement reliability

 

SPECIFICATIONS

Pressure Specifications

Measuring principle Coriolis
Product headline

Highest capacity four-tube flowmeter with a compact, easily accessible transmitter.

For highest flow rates and outstanding performance in on/offshore oil and gas applications.

Sensor features

Increased profit – single installation point providing premium accuracy for large quantities. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.

Nominal diameter: DN 300 to 400 (12 to 16"). Four-tube system with low pressure drop. Complete exterior design made of 1.4435 (316L).

Transmitter features

Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.

Compact dual-compartment housing with up to 3 I/Os.

Nominal diameter range DN 300 to 400 (12 to 16")
Wetted materials

Measuring tube: 1.4404 (316/316L)

Connection: 1.4404 (316/316L)

Measured variables Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration
Max. measurement error

Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)

Volume flow (liquid): ±0.10 %

Mass flow (gas): ±0.35 %

Density (liquid): ±0.0005 g/cm³

Measuring range 0 to 4100 t/h (0 to 4520 tn. sh./h)
Max. process pressure PN 100, Class 600
Medium temperature range –50 to +180 °C (–58 to +356 °F)
Ambient temperature range

Standard: –40 to +60 °C (–40 to +140 °F)

Option: –50 to +60 °C (–58 to +140 °F)

Sensor housing material 1.4404 (316L), highest corrosion resistance
Transmitter housing material AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L
Degree of protection IP66/67, type 4X enclosure
Display/Operation

4-line backlit display with touch control (operation from outside)

Configuration via local display and operating tools possible

Remote display available"

Outputs

3 outputs:

4-20 mA HART (active/passive)

4-20 mA WirelessHART

4-20 mA (active/passive)

Pulse/frequency/switch output (active/passive)

Double pulse output (active/passive)

Relay output

Inputs

Status input

4-20 mA input

Digital communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Power supply

DC 24 V

AC 100 to 230 V

AC 100 to 230 V / DC 24 V (non-hazardous area)

Hazardous area approvals ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC
Product safety CE, C-tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)

Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

MI-005 Liquids other than water (Hydrocarbons), LPG, cryogenic

MI-002, PTB

Marine approvals and certificates LR approval, DNV approval, ABS approval, BV approval, CCS approval
Pressure approvals and certificates PED, CRN
Material certificates

3.1 material

NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK

Gas Specifications

 

Measuring principle Coriolis
Product headline

Highest capacity four-tube flowmeter with a compact, easily accessible transmitter.

For highest flow rates and outstanding performance in on/offshore oil and gas applications.

Sensor features Increased profit – single installation point providing premium accuracy for large quantities. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Nominal diameter: DN 300 to 400 (12 to 16"). Four-tube system with low pressure drop. Complete exterior design made of 1.4435 (316L).
Transmitter features

Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.

Compact dual-compartment housing with up to 3 I/Os.

Nominal diameter range DN 300 to 400 (12 to 16")
Wetted materials

Measuring tube: 1.4404 (316/316L)

Connection: 1.4404 (316/316L)

Measured variables Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration
Max. measurement error

Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)

Volume flow (liquid): ±0.10 %

Mass flow (gas): ±0.35 %

Density (liquid): ±0.0005 g/cm³

Measuring range 0 to 4100 t/h (0 to 4520 tn. sh./h)
Max. process pressure PN 100, Class 600
Medium temperature range –50 to +180 °C (–58 to +356 °F)
Ambient temperature range

Standard: –40 to +60 °C (–40 to +140 °F)

Option: –50 to +60 °C (–58 to +140 °F)

Sensor housing material 1.4404 (316L), highest corrosion resistance
Transmitter housing material AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L
Degree of protection IP66/67, type 4X enclosure
Display/Operation

4-line backlit display with touch control (operation from outside)

Configuration via local display and operating tools possible

Remote display available

Outputs

3 outputs:

4-20 mA HART (active/passive)

4-20 mA WirelessHART

4-20 mA (active/passive)

Pulse/frequency/switch output (active/passive)

Double pulse output (active/passive)

Relay output

Inputs

Status input

4-20 mA input

Digital communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Power supply

DC 24 V

AC 100 to 230 V

AC 100 to 230 V / DC 24 V (non-hazardous area)

Hazardous area approvals ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC
Product safety CE, C-tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)

Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

MI-005 Liquids other than water (Hydrocarbons), LPG, cryogenic

MI-002, PTB

 Marine approvals and certificates  LR approval, DNV approval, ABS approval, BV approval, CCS approval
 Pressure approvals and certificates  PED, CRN
 Material certificates  3.1 material

NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK

Density Concentration Specification

Measuring principle Coriolis
Product headline

Highest capacity four-tube flowmeter with a compact, easily accessible transmitter.

For highest flow rates and outstanding performance in on/offshore oil and gas applications.

Sensor features

Increased profit – single installation point providing premium accuracy for large quantities. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.

Nominal diameter: DN 300 to 400 (12 to 16"). Four-tube system with low pressure drop. Complete exterior design made of 1.4435 (316L).

 Transmitter features  Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.

Compact dual-compartment housing with up to 3 I/Os.

 Nominal diameter range  DN 300 to 400 (12 to 16")
 Wetted materials  Measuring tube: 1.4404 (316/316L)

Connection: 1.4404 (316/316L)

 Measured variables  Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration
 Max. measurement error Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)

Volume flow (liquid): ±0.10 %

Mass flow (gas): ±0.35 %

Density (liquid): ±0.0005 g/cm³

 Measuring range  0 to 4100 t/h (0 to 4520 tn. sh./h)
 Max. process pressure  PN 100, Class 600
 Medium temperature range  –50 to +180 °C (–58 to +356 °F)
 Ambient temperature range  Standard: –40 to +60 °C (–40 to +140 °F)

Option: –50 to +60 °C (–58 to +140 °F)

 Sensor housing material  1.4404 (316L), highest corrosion resistance
 Transmitter housing material  AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L
 Degree of protection  IP66/67, type 4X enclosure
 Display/Operation  4-line backlit display with touch control (operation from outside)

Configuration via local display and operating tools possible

Remote display available"

 Outputs  3 outputs:

4-20 mA HART (active/passive)

4-20 mA WirelessHART

4-20 mA (active/passive)

Pulse/frequency/switch output (active/passive)

 Double pulse output (active/passive)  Relay output
 Inputs Status input

4-20 mA input

 Digital communication  HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
 Power supply DC 24 V

AC 100 to 230 V

AC 100 to 230 V / DC 24 V (non-hazardous area)

 Hazardous area approvals  ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC
 Product safety  CE, C-tick, EAC marking
 Functional safety  Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
 Metrological approvals and certificates  Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)

Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

MI-005 Liquids other than water (Hydrocarbons), LPG, cryogenic

MI-002, PTB

 Marine approvals and certificates  LR approval, DNV approval, ABS approval, BV approval, CCS approval
 Pressure approvals and certificates  PED, CRN
 Material certificates  3.1 material

NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK

 

Documents

You may want to read this product's catalog. If so, please click to view the Endress+Hauser Proline Promass X 300 Series datasheet.
View AllClose