Endress+Hauser
High-pressure Coriolis Flowmeter Proline Promass O 100
- SKU:
- Proline Promass O 100 Series
- MPN:
- Proline Promass O 100
- Weight:
- 0.00 Grams
Description
Application
The Promass O is engineered for exceptional precision in measuring liquids and gases under extremely high process pressures, making it ideal for use in the oil and gas industry. It is fully capable of withstanding offshore conditions and resistant to stress corrosion cracking. With its ultra-compact transmitter, the Promass O 100 provides top performance while occupying minimal space, allowing for effortless system integration. Its Heartbeat Technology ensures continuous process safety. The measuring principle functions independently of physical fluid properties such as viscosity and density.
- Designed for superior accuracy under the highest process pressures, perfectly suited for offshore environments.
Device Features:
- Measuring tube made from 25Cr Duplex, 1.4410 (UNS S32750)
- Handles process pressures up to PN 250 (Class 1500)
- Nominal diameter range: DN 80 to 150 (3 to 6 inches)
- Durable, ultra-compact transmitter housing
- High ingress protection: IP69K
- Optional local display
Benefits
- Maximum safety: Exceptional resistance to stress corrosion cracking.
- Fewer measuring points: Provides multivariable measurement, covering flow, density, and temperature.
- Space-efficient installation: No need for in/outlet runs.
- Compact transmitter: Delivers full functionality in a minimal footprint.
- Time-saving operation: Local operation is possible without requiring additional software or hardware, thanks to the integrated web server.
- Integrated verification: Heartbeat Technology enables ongoing system verification without interrupting operations.
Documents
You may want to read this product's catalog. If so, please click to view the Proline Promass O 100 Series datasheet.SPECIFICATIONS
Liquids Specifications
Measuring principle | Coriolis |
Product headline | Robust high-pressure flowmeter with an ultra-compact transmitter. For premium accuracy at highest process pressures, fully suitable for offshore conditions. |
Sensor features | Maximum safety – highest resistance to stress corrosion cracking. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Measuring tube in 25Cr Duplex, 1.4410 (UNS S32750). Process pressure up to PN 250 (Class 1500). Nominal diameter: DN 80 to 150 (3 to 6"). |
Transmitter features | Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available. |
Nominal diameter range | DN 80 to 150 (3 to 6") |
Wetted materials | Measuring tube: 25Cr duplex (Super Duplex), 1.4410 (UNS S32750) Connection: 25Cr duplex (Super Duplex), 1.4410 (F53) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.1 (standard), 0.05 % (option) Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 800,000 kg/h (0 to 29,400 lb/min) |
Max. process pressure | PN 250, Class 1500 |
Medium temperature range | –40 to +205 °C (–40 to +401 °F) |
Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
Sensor housing material | 1.4404 (316L), highest corrosion resistance |
Transmitter housing material | Compact: AlSi10Mg, coated Compact/ultra‐compact: 1.4404 (316L) |
Degree of protection | Standard: IP66/67, type 4X enclosure Option: IP69 |
Display/Operation | 4‐line backlit display available (no local operation) Configuration via web browser and operating tools possible |
Outputs | 4-20 mA HART (active) Pulse/frequency/switch output (passive) |
Inputs | None |
Digital communication | HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET |
Power supply | DC 20 to 30 V |
Hazardous area approvals | ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC |
Product safety | CE, C-Tick, EAC marking |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval, CCS approval |
Pressure approvals and certificates | PED, CRN, AD 2000 |
Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK |
Gas Specifications
Measuring principle | Coriolis |
Product headline | Robust high-pressure flowmeter with an ultra-compact transmitter. For premium accuracy at highest process pressures, fully suitable for offshore conditions. |
Sensor features | Maximum safety – highest resistance to stress corrosion cracking. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Measuring tube in 25Cr Duplex, 1.4410 (UNS S32750). Process pressure up to PN 250 (Class 1500). Nominal diameter: DN 80 to 250 (3 to 10"). |
Transmitter features | Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available. |
Nominal diameter range | DN 80 to 150 (3 to 6") |
Wetted materials | Measuring tube: 25Cr duplex (Super Duplex), 1.4410 (UNS S32750) Connection: 25Cr duplex (Super Duplex), 1.4410 (F53) Measuring tube: 1.4539 (904L) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.1 (standard), 0.05 % (option) Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 800,000 kg/h (0 to 29,400 lb/min) |
Max. process pressure | PN 250, Class 1500 |
Medium temperature range | –40 to +205 °C (–40 to +401 °F) |
Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
Sensor housing material | 1.4404 (316L), highest corrosion resistance |
Transmitter housing material | Compact: AlSi10Mg, coated Compact/ultra‐compact: 1.4404 (316L) |
Degree of protection | Standard: IP66/67, type 4X enclosure Option: IP69 |
Display/Operation | 4‐line backlit display available (no local operation) Configuration via web browser and operating tools possible |
Outputs | 4-20 mA HART (active) Pulse/frequency/switch output (passive) |
Inputs | None |
Digital communication | HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET |
Power supply | DC 20 to 30 V |
Hazardous area approvals | ATEX, IECEx, cCSAus, INMETRO, NEPSI |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval, CCS approval |
Pressure approvals and certificates | PED, CRN, AD 2000 |
Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK |
Density/Concentration Specifications
Measuring principle | Coriolis |
Product headline | Robust high-pressure flowmeter with an ultra-compact transmitter. For premium accuracy at highest process pressures, fully suitable for offshore conditions. |
Sensor features | Maximum safety – highest resistance to stress corrosion cracking. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Measuring tube in 25Cr Duplex, 1.4410 (UNS S32750). Process pressure up to PN 250 (Class 1500). Nominal diameter: DN 80 to 250 (3 to 10"). |
Transmitter features | Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available. |
Nominal diameter range | DN 80 to 150 (3 to 6") |
Wetted materials | Measuring tube: 25Cr duplex (Super Duplex), 1.4410 (UNS S32750) Connection: 25Cr duplex (Super Duplex), 1.4410 (F53) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.1 (standard), 0.05 % (option) Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 800,000 kg/h (0 to 29,400 lb/min) |
Max. process pressure | PN 250, Class 1500 |
Medium temperature range | –40 to +205 °C (–40 to +401 °F) |
Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
Sensor housing material | 1.4404 (316L), highest corrosion resistance |
Transmitter housing material | Compact: AlSi10Mg, coated Compact/ultra‐compact: 1.4404 (316L) |
Degree of protection | Standard: IP66/67, type 4X enclosure Option: IP69 |
Display/Operation | 4‐line backlit display available (no local operation) Configuration via web browser and operating tools possible |
Outputs | 4-20 mA HART (active) Pulse/frequency/switch output (passive) |
Inputs | None |
Digital communication | HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET |
Power supply | DC 20 to 30 V |
Hazardous area approvals | ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC |
Product safety | CE, C-Tick |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval |
Pressure approvals and certificates | PED, CRN, AD 2000 |
Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK |