Endress+Hauser
High-pressure Coriolis Flowmeter Proline Promass O 500
- SKU:
- Proline Promass O 500 Series
- MPN:
- Proline Promass O 500
- Weight:
- 0.00 Grams
Description
Application
The Promass O is engineered for exceptional accuracy in measuring liquids and gases under extreme process pressures, making it ideal for the oil and gas industry. Its robust design ensures suitability for offshore applications and resistance to stress corrosion cracking. With its advanced remote transmitter, the Promass O 500 enhances installation flexibility and operational safety in challenging environments. Heartbeat Technology ensures reliable process safety. The measuring principle is unaffected by fluid properties such as viscosity or density, providing premium accuracy even under the highest process pressures and in offshore conditions.
Device Properties
- Measuring tube made from 25Cr Duplex, 1.4410 (UNS S32750)
- Process pressure capability up to PN 250 (Class 1500)
- Available nominal diameters: DN 80 to 250 (3" to 10")
- Remote version with up to 4 I/O channels
- Backlit display with touch control and WLAN access
- Standard sensor-to-transmitter cable connection
Benefits
- Maximum safety with high resistance to stress corrosion cracking
- Reduced need for additional process measuring points thanks to multivariable measurement (flow, density, temperature)
- Space-saving installation—no inlet or outlet runs required
- Comprehensive access to process and diagnostic information through numerous, customizable I/O options and Ethernet connectivity
- Simplified system complexity with configurable I/O functionality
- Built-in verification via Heartbeat Technology for continuous process monitoring
Documents
You may want to read this product's catalog. If so, please click to view the Proline Promass O 500 Series datasheet.SPECIFICATIONS
Liquids Specifications
Measuring principle | Coriolis |
Product headline | Robust high-pressure flowmeter, as remote version with up to 4 I/Os. For premium accuracy at highest process pressures, fully suitable for offshore conditions. |
Sensor features | Maximum safety – highest resistance to stress corrosion cracking. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space-saving installation – no in-/outlet run needs. Measuring tube in 25Cr Duplex, 1.4410 (UNS S32750). Process pressure up to PN 250 (Class 1500). Nominal diameter: DN 80 to 250 (3 to 10"). |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Nominal diameter range | DN 80 to 250 (3 to 10") |
Wetted materials | Measuring tube: 25Cr duplex (Super Duplex), 1.4410 (UNS S32750) Connection: 25Cr duplex (Super Duplex), 1.4410 (F53) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.10 % (standard), 0.05 % (option) Volume flow (liquid): ±0.10 % Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 2,200,000 kg/h (0 to 80,850 lb/min) |
Max. process pressure | PN 250, Class 1500 |
Medium temperature range | –40 to +205 °C (–40 to +401 °F) |
Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
Sensor housing material | 1.4404 (316L), highest corrosion resistance Sensor connection housing (standard): AlSi10Mg, coated Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L |
Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat |
Degree of protection | Sensor remote version (standard): IP66/67, type 4X enclosure Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure |
Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
Outputs | 4 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
Inputs | Status input 4-20 mA input |
Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
Product safety | CE, C-tick, EAC marking |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) MI-005 Liquids other than water (Hydrocarbons), Cryogenic Liquids, LPG OIML R117 Liquids other than water, Cryogenic Liquids, LPG MI-002, PTB |
Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval, CCS approval |
Pressure approvals and certificates | PED, CRN, AD 2000 |
Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK |
Gas Specifications
Measuring principle | Coriolis |
Product headline | Robust high-pressure flowmeter, as remote version with up to 4 I/Os. For premium accuracy at highest process pressures, fully suitable for offshore conditions. |
Sensor features | Maximum safety – highest resistance to stress corrosion cracking. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space-saving installation – no in-/outlet run needs. Measuring tube in 25Cr Duplex, 1.4410 (UNS S32750). Process pressure up to PN 250 (Class 1500). Nominal diameter: DN 80 to 250 (3 to 10"). |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Nominal diameter range | DN 80 to 250 (3 to 10") |
Wetted materials | Measuring tube: 25Cr duplex (Super Duplex), 1.4410 (UNS S32750) Connection: 25Cr duplex (Super Duplex), 1.4410 (F53) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.10 % (standard), 0.05 % (option) Volume flow (liquid): ±0.10 % Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 2,200,000 kg/h (0 to 80,850 lb/min) |
Max. process pressure | PN 250, Class 1500 |
Medium temperature range | –40 to +205 °C (–40 to +401 °F) |
Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
Sensor housing material | 1.4404 (316L), highest corrosion resistance Sensor connection housing (standard): AlSi10Mg, coated Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L |
Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat |
Degree of protection | Sensor remote version (standard): IP66/67, type 4X enclosure Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure |
Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
Outputs | 4 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
Inputs | Status input 4-20 mA input |
Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
Product safety | CE, C-tick, EAC marking |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) MI-005 Liquids other than water (Hydrocarbons), Cryogenic Liquids, LPG OIML R117 Liquids other than water, Cryogenic Liquids, LPG MI-002, PTB |
Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval, CCS approval |
Pressure approvals and certificates | PED, CRN, AD 2000 |
Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK |
Steam Specifications
Measuring principle | Coriolis |
Product headline | Robust high-pressure flowmeter, as remote version with up to 4 I/Os. For premium accuracy at highest process pressures, fully suitable for offshore conditions. |
Sensor features | Maximum safety – highest resistance to stress corrosion cracking. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space-saving installation – no in-/outlet run needs. Measuring tube in 25Cr Duplex, 1.4410 (UNS S32750). Process pressure up to PN 250 (Class 1500). Nominal diameter: DN 80 to 250 (3 to 10"). |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Nominal diameter range | DN 80 to 150 (3 to 6") |
Wetted materials | Measuring tube: 25Cr duplex (Super Duplex), 1.4410 (UNS S32750) Connection: 25Cr duplex (Super Duplex), 1.4410 (F53) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.10 % (standard), 0.05 % (option) Volume flow (liquid): ±0.10 % Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 800,000 kg/h (0 to 29,400 lb/min) |
Max. process pressure | PN 250, Class 1500 |
Medium temperature range | –40 to +205 °C (–40 to +401 °F) |
Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
Sensor housing material | 1.4404 (316L), highest corrosion resistance Sensor connection housing (standard): AlSi10Mg, coated Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L |
Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat |
Degree of protection | Sensor remote version (standard): IP66/67, type 4X enclosure Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure |
Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
Outputs | 4 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
Inputs | Status input 4-20 mA input |
Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
Product safety | CE, C-tick, EAC marking |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) MI-005 Liquids other than water (Hydrocarbons), Cryogenic Liquids, LPG OIML R117 Liquids other than water, Cryogenic Liquids, LPG MI-002, PTB |
Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval, CCS approval |
Pressure approvals and certificates | PED, CRN, AD 2000 |
Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK |
Density/Concentration Specifications
Measuring principle | Coriolis |
Product headline | Robust high-pressure flowmeter, as remote version with up to 4 I/Os. For premium accuracy at highest process pressures, fully suitable for offshore conditions. |
Sensor features | Maximum safety – highest resistance to stress corrosion cracking. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space-saving installation – no in-/outlet run needs. Measuring tube in 25Cr Duplex, 1.4410 (UNS S32750). Process pressure up to PN 250 (Class 1500). Nominal diameter: DN 80 to 250 (3 to 10"). |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Nominal diameter range | DN 80 to 250 (3 to 10") |
Wetted materials | Measuring tube: 25Cr duplex (Super Duplex), 1.4410 (UNS S32750) Connection: 25Cr duplex (Super Duplex), 1.4410 (F53) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.10 % (standard), 0.05 % (option) Volume flow (liquid): ±0.10 % Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 2,200,000 kg/h (0 to 80,850 lb/min) |
Max. process pressure | PN 250, Class 1500 |
Medium temperature range | –40 to +205 °C (–40 to +401 °F) |
Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
Sensor housing material | 1.4404 (316L), highest corrosion resistance Sensor connection housing (standard): AlSi10Mg, coated Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L |
Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat |
Degree of protection | Sensor remote version (standard): IP66/67, type 4X enclosure Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure |
Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
Outputs | 4 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
Inputs | Status input 4-20 mA input |
Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
Product safety | CE, C-tick, EAC marking |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) MI-005 Liquids other than water (Hydrocarbons), Cryogenic Liquids, LPG OIML R117 Liquids other than water, Cryogenic Liquids, LPG MI-002, PTB |
Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval, CCS approval |
Pressure approvals and certificates | PED, CRN, AD 2000 |
Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK |