Endress+Hauser
High-pressure Mating Pipes Flowmeter Proline Prowirl O 200
- SKU:
- Proline Prowirl O 200 series
- Weight:
- 0.00 Grams
Description
Application
The Prowirl O is ideally designed for reliable process control in demanding gas and steam applications with high process pressure. Its construction ensures maximum safety in both main and ancillary processes. Utilizing genuine loop-powered technology, the Prowirl O 200 allows for cost-effective and seamless integration into existing infrastructures, providing the highest level of operational safety in hazardous environments. Heartbeat Technology guarantees continuous process safety.
Preferred for measuring wet, saturated, and superheated steam, as well as gases and liquids (including cryogenic applications).
Specialized for applications with high process pressure.
Device properties:
- Saturated steam mass flow up to PN 250 (Class 1500)
- Full compliance with NACE (MR0175/MR0103)
- Flexible positioning of the pressure cell
- Display module with data transfer function
- Robust dual-compartment housing
- Plant safety: worldwide certifications (SIL, hazardous area)
Benefits
- Improved process control with integrated temperature and pressure measurement for steam and gases
- Enhanced mechanical integrity for flow measurement with a specialized sensor design
- Consistent accuracy down to Re 10,000 with the most linear vortex meter body
- Long-term stability through a robust, drift-free capacitive sensor
- Convenient wiring with a separate connection compartment and various Ethernet options
- Safe operation with no need to open the device
- Integrated verification with Heartbeat Technology
SPECIFICATIONS
Liquids Specifications
Measuring principle
|
Vortex |
Product headline
|
Flowmeter optimized for requirements of high-pressure mating pipes. Better process control – integrated temperature and pressure measurement for steam and gases. The specialist for applications with high process pressure.
|
Sensor features
|
Increased mechanical integrity for flow measurement – special sensor design. Same accuracy down to Re 10 000 – most linear Vortex meter body. Long-term stability – robust drift-free capacitive sensor. Saturated steam mass flow up to PN 250 (Class 1500). Full compliance with NACE (MR0175/MR0103). Flexible positioning of pressure cell.
|
Transmitter features
|
Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
|
Nominal diameter range
|
DN 15 to 300 (½ to 12")
|
Wetted materials
|
Measuring tube: 1.4408 (CF3M) DSC sensor: UNS N07718 similar to Alloy 718, 2.4668 Process connection: 1.4404/F316/F316L
|
Measured variables
|
Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
|
Max. measurement error
|
Volume flow (liquid): ±0.75 % Volume flow (steam, gas): ±1.00 % Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated) Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure compensation) Mass flow (liquid): ±0.85%
|
Measuring range
|
Liquid: 0.1 to 1700 m³/h (0.061 to 1000 ft³/min) depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) Steam, gas: 0.52 to 22000 m³/h (0.31 to 13000 ft³/min) depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
|
Max. process pressure |
PN 250, Class 1500, 40K
|
Medium temperature range
|
Standard: –40 to +260 °C (–40 to +500 °F) High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
|
Ambient temperature range
|
Compact version (standard): –40 to +80 °C (–40 to +176 °F) Compact version (option): –50 to +80 °C (–58 to +176 °F) Remote version (standard): –40 to +85 °C (–40 to +185 °F) Remote version (option): –50 to +85 °C (–58 to +185 °F)
|
Sensor housing material
|
Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)
|
Transmitter housing material
|
AlSi10Mg, coated; 1.4404 (316L)
|
Degree of protection
|
Compact version: IP66/67, type 4X enclosure Sensor remote version: IP66/67, type 4X enclosure Transmitter remote version: IP66/67, type 4X enclosure
|
Display/Operation
|
4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available
|
Outputs |
4‐20 mA HART (passive) 4‐20 mA (passive) Pulse/frequency/switch output (passive)
|
Inputs
|
4‐20 mA (passive) |
Digital communication
|
HART, PROFIBUS PA, FOUNDATION Fieldbus
|
Power supply
|
DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output) DC 12 to 30 V (4‐20 mA HART, 4‐20 mA) DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input) DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)
|
Hazardous area approvals
|
ATEX, IECEx, cCSAus, JPN
|
Product safety
|
CE, C-TICK, EAC, UK Ex |
Functional safety
|
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates
|
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
|
Marine approvals and certificates
|
ABS, LR, BV, DNV
|
Pressure approvals and certificates
|
PED, CRN
|
Material certificates
|
3.1 material NACE MR0175/MR0103, PMI (on request); only Class 900/1500: welding test acc. to ISO 15614‐1, similar to ASME IX (on request)
|
Gas Specifications
Measuring principle
|
Vortex |
Product headline
|
Flowmeter optimized for requirements of high-pressure mating pipes. Better process control – integrated temperature and pressure measurement for steam and gases. The specialist for applications with high process pressure.
|
Sensor features
|
Increased mechanical integrity for flow measurement – special sensor design. Same accuracy down to Re 10 000 – most linear Vortex meter body. Long-term stability – robust drift-free capacitive sensor. Saturated steam mass flow up to PN 250 (Class 1500). Full compliance with NACE (MR0175/MR0103). Flexible positioning of pressure cell.
|
Transmitter features
|
Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
|
Nominal diameter range
|
DN 15 to 300 (½ to 12") |
Wetted materials
|
Measuring tube: 1.4408 (CF3M) DSC sensor: UNS N07718 similar to Alloy 718, 2.4668 Process connection: 1.4404/F316/F316L
|
Measured variables
|
Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
|
Max. measurement error
|
Volume flow (liquid): ±0.75 % Volume flow (steam, gas): ±1.00 % Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated) Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure compensation) Mass flow (liquid): ±0.85%
|
Measuring range
|
Liquid: 0.1 to 1700 m³/h (0.061 to 1000 ft³/min) depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) Steam, gas: 0.52 to 22000 m³/h (0.31 to 13000 ft³/min) depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
|
Max. process pressure
|
PN 250, Class 1500, 40K |
Medium temperature range
|
Standard: –40 to +260 °C (–40 to +500 °F) High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
|
Ambient temperature range |
Compact version (standard): –40 to +80 °C (–40 to +176 °F) Compact version (option): –50 to +80 °C (–58 to +176 °F) Remote version (standard): –40 to +85 °C (–40 to +185 °F) Remote version (option): –50 to +85 °C (–58 to +185 °F)
|
Sensor housing material
|
Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)
|
Transmitter housing material
|
AlSi10Mg, coated; 1.4404 (316L)
|
Degree of protection
|
Compact version: IP66/67, type 4X enclosure Sensor remote version: IP66/67, type 4X enclosure Transmitter remote version: IP66/67, type 4X enclosure
|
Display/Operation
|
4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available
|
Outputs
|
4‐20 mA HART (passive) 4‐20 mA (passive) Pulse/frequency/switch output (passive)
|
Inputs
|
4‐20 mA (passive)
|
Digital communication
|
HART, PROFIBUS PA, FOUNDATION Fieldbus
|
Power supply
|
DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output) DC 12 to 30 V (4‐20 mA HART, 4‐20 mA) DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input) DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)
|
Hazardous area approvals
|
ATEX, IECEx, cCSAus, JPN, EAC, UK Ex
|
Product safety
|
CE, C-TICK, EAC
|
Functional safety
|
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates
|
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
|
Marine approvals and certificates
|
ABS, LR, BV, DNV
|
Pressure approvals and certificates
|
PED, CRN
|
Material certificates
|
3.1 material NACE MR0175/MR0103, PMI (on request); only Class 900/1500: welding test acc. to ISO 15614‐1, similar to ASME IX (on request)
|
Steam Specifications
Measuring principle
|
Vortex |
Product headline
|
Flowmeter optimized for requirements of high-pressure mating pipes. Better process control – integrated temperature and pressure measurement for steam and gases. The specialist for applications with high process pressure.
|
Sensor features
|
Increased mechanical integrity for flow measurement – special sensor design. Same accuracy down to Re 10 000 – most linear Vortex meter body. Long-term stability – robust drift-free capacitive sensor. Saturated steam mass flow up to PN 250 (Class 1500). Full compliance with NACE (MR0175/MR0103). Flexible positioning of pressure cell.
|
Transmitter features
|
Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
|
Nominal diameter range
|
DN 15 to 300 (½ to 12")
|
Wetted materials
|
Measuring tube: 1.4408 (CF3M) DSC sensor: UNS N07718 similar to Alloy 718, 2.4668 Process connection: 1.4404/F316/F316L
|
Measured variables
|
Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
|
Max. measurement error
|
Volume flow (liquid): ±0.75 % Volume flow (steam, gas): ±1.00 % Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated) Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure compensation) Mass flow (liquid): ±0.85%
|
Measuring range
|
Liquid: 0.1 to 1700 m³/h (0.061 to 1000 ft³/min) depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) Steam, gas: 0.52 to 22000 m³/h (0.31 to 13000 ft³/min) depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
|
Max. process pressure
|
PN 250, Class 1500, 40K
|
Medium temperature range
|
Standard: –40 to +260 °C (–40 to +500 °F) High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
|
Ambient temperature range
|
Compact version (standard): –40 to +80 °C (–40 to +176 °F) Compact version (option): –50 to +80 °C (–58 to +176 °F) Remote version (standard): –40 to +85 °C (–40 to +185 °F) Remote version (option): –50 to +85 °C (–58 to +185 °F)
|
Sensor housing material
|
Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)
|
Transmitter housing material
|
AlSi10Mg, coated; 1.4404 (316L)
|
Degree of protection
|
Compact version: IP66/67, type 4X enclosure Sensor remote version: IP66/67, type 4X enclosure Transmitter remote version: IP66/67, type 4X enclosure
|
Display/Operation |
4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available
|
Outputs
|
4‐20 mA HART (passive) 4‐20 mA (passive) Pulse/frequency/switch output (passive)
|
Inputs
|
4‐20 mA (passive)
|
Digital communication
|
HART, PROFIBUS PA, FOUNDATION Fieldbus
|
Power supply
|
DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output) DC 12 to 30 V (4‐20 mA HART, 4‐20 mA) DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input) DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)
|
Hazardous area approvals
|
ATEX, IECEx, cCSAus, JPN, EAC, UK Ex
|
Product safety
|
CE, C-TICK, EAC |
Functional safety
|
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates
|
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
|
Marine approvals and certificates
|
ABS, LR, BV, DNV
|
Pressure approvals and certificates
|
PED, CRN
|
Material certificates
|
3.1 material NACE MR0175/MR0103, PMI (on request); only Class 900/1500: welding test acc. to ISO 15614‐1, similar to ASME IX (on request)
|
Documents
You may want to read this product's catalog. If so, please click to view the Endress+Hauser Proline Prowirl O 200 series datasheet.