Description
Application
Field of Application
The Promass P 100 combines the superior performance of a bent-tube flowmeter with the cleanability of a straight-tube design, all without compromise. With the smallest transmitter housing on the market, it provides full functionality in the most compact space. It is specifically designed for use in sterile environments where space is limited, making it the ideal choice for system integrators, skid builders, and equipment manufacturers.
The measuring principle is independent of fluid properties such as viscosity and density, ensuring reliable operation. This flowmeter is specially tailored for sterile conditions in the life sciences industry.
Device Properties
- Compliant with ASME BPE, 3-A, and EHEDG standards, featuring low delta ferrite levels
- Electropolished measuring tube made from 1.4435 (316L) stainless steel
- Quick recovery after CIP/SIP processes
- Sturdy, ultra-compact transmitter housing
- High ingress protection: IP69K
- Optional local display for ease of use
Benefits
- Ensures the highest process quality by fully adhering to industry standards
- Reduces the need for multiple measuring points with multivariable measurement (flow, density, temperature)
- Space-efficient installation with no requirement for in/outlet runs
- Compact transmitter offering full functionality in minimal space
- Saves time with local operation – no need for additional software or hardware, thanks to the integrated web server
- Includes built-in verification with Heartbeat Technology for continuous system monitoring
SPECIFICATIONS
Pressure Specifications
Measuring principle | Coriolis |
Product headline |
Specialist for life sciences with an ultra-compact transmitter. Dedicated to applications under sterile conditions in the life sciences industry. |
Sensor features |
Highest process quality – fully compliant to industry requirements. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. ASME BPE, 3‐A and EHEDG conform & low delta ferrite. Electropolished measuring tube in 1.4435 (316L). Fast recovery from CIP/SIP. |
Transmitter features |
Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology. Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available. |
Nominal diameter range | DN 8 to 50 (⅜ to 2") |
Wetted materials |
Measuring tube: 1.4435 (316L) Connection: 1.4435 (316L); 1.4404 (316/316L) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
Max. measurement error |
Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 70 000 kg/h (0 to 2570 lb/min) |
Max. process pressure | PN 63, Class 300, 40K |
Medium temperature range |
Standard: –50 to +150 °C (–58 to +302 °F) Option: –50 to +205 °C (–58 to +401 °F) |
Ambient temperature range |
Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
Sensor housing material | 1.4301 (304), corrosion resistant |
Transmitter housing material | Compact: AlSi10Mg, coated
Compact/ultra‐compact: 1.4301 (304) |
Degree of protection | Standard: IP66/67, type 4X enclosure
Option: IP69 |
Display/Operation | 4‐line backlit display available (no local operation)
Configuration via web browser and operating tools possible |
Outputs | 4‐20 mA HART (active)
Pulse/frequency/switch output (passive) |
Inputs | None |
Digital communication | HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET |
Power supply | DC 20 to 30 V |
Hazardous area approvals | ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC |
Product safety | CE, C-Tick, EAC marking |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Verification: Heartbeat Technology complies with requirements for traceable verification according to ISO 9001:2008, chapter 7.6. a (TUV attestation) |
Pressure approvals and certificates | PED, CRN |
Material certificates | 3.1 material |
Hygienic approvals and certificates | 3-A, EHEDG, ASME BPE, ISPE, cGMP |
Gas Specifications
Measuring principle | Coriolis |
Hygienic approvals and certificates | cGMP |
Density Concentration Specification
Measuring principle | Coriolis |
Product headline | Specialist for life sciences with an ultra-compact transmitter.
Dedicated to applications under sterile conditions in the life sciences industry. |
Sensor features | Highest process quality – fully compliant to industry requirements. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
ASME BPE, 3‐A and EHEDG conform & low delta ferrite. Electropolished measuring tube in 1.4435 (316L). Fast recovery from CIP/SIP. |
Transmitter features |
Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology. Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available. |
Nominal diameter range | DN 8 to 50 (⅜ to 2") |
Wetted materials | Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 % Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 70 000 kg/h (0 to 2570 lb/min) |
Max. process pressure | PN 63, Class 300, 40K |
Medium temperature range | Standard: –50 to +150 °C (–58 to +302 °F)
Option: –50 to +205 °C (–58 to +401 °F) |
Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F) |
Sensor housing material | 1.4301 (304), corrosion resistant |
Transmitter housing material | Compact: AlSi10Mg, coated
Compact/ultra‐compact: 1.4301 (304) |
Degree of protection | Standard: IP66/67, type 4X enclosure
Option: IP69 |
Display/Operation | 4‐line backlit display available (no local operation)
Configuration via web browser and operating tools possible |
Outputs | 4‐20 mA HART (active)
Pulse/frequency/switch output (passive) |
Inputs | None |
Digital communication | HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET |
Power supply | DC 20 to 30 V |
Hazardous area approvals | ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC |
Product safety | CE, C-Tick, EAC marking |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Verification: Heartbeat Technology complies with requirements for traceable verification according to ISO 9001:2008, chapter 7.6. a (TUV attestation) |
Pressure approvals and certificates | PED, CRN |
Material certificates | 3.1 material |
Hygienic approvals and certificates | 3-A, EHEDG, ASME BPE, ISPE, cGMP |
Documents
You may want to read this product's catalog. If so, please click to view the Endress+Hauser Proline Promass P 100 Series datasheet.