Endress+Hauser
High-temperature Electromagnetic Flowmeter Proline Promag P 200
- SKU:
- High-temperature Electromagnetic Flowmeter Proline Promag P 200
- Weight:
- 0.00 Grams
Description
Application
The Promag P is specifically designed for chemical and industrial processes involving corrosive liquids and high-temperature mediums. With its innovative loop-powered technology, the Promag P 200 ensures cost-efficient and easy integration into existing systems. Its intrinsically safe design (Ex ia) guarantees maximum operational safety in hazardous environments. The device’s Heartbeat Technology continuously monitors process safety, providing reliable performance at all times.
The bidirectional measurement principle operates independently of pressure, density, temperature, and viscosity.
Designed for chemical and industrial processes with corrosive liquids and high-temperature applications.
Device Features
- Maximum nominal diameter: DN 200 (8")
- Full range of Ex certifications
- PTFE or PFA lining options
- Loop-powered operation
- Durable two-chamber housing
- Plant safety ensured through global approvals (SIL, hazardous area certifications)
Benefits
- Broad application versatility – Compatible with a wide range of wetted materials
- Energy-efficient flow measurement – No pressure loss due to design without cross-section constriction
- Maintenance-free – No moving parts for reduced upkeep
- Simplified wiring – Dedicated connection compartment for easy installation
- Safe and convenient operation – No need to open the device; features a touch-controlled display with background lighting
- Built-in verification – Heartbeat Technology for continuous process monitorin
SPECIFICATIONS
Pressure Specifications
Measuring principle |
Electromagnetic |
Product headline |
The flowmeter for highest medium temperatures with genuine loop-powered technology. Dedicated to chemical and process applications with corrosive liquids and high medium temperatures. |
Sensor features |
Diverse applications – wide variety of wetted materials. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts. Nominal diameter: max. DN 200 (8"). All common Ex approvals. Liner made of PTFE or PFA. |
Transmitter features |
Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area). |
Nominal diameter range | DN 15 to 200 (½ to 8") |
Wetted materials |
Liner: PFA; PTFE Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum |
Measured variables | Volume flow, mass flow |
Max. measurement error | Volume flow: ±0.5 % o.r. ± 2 mm/s (0.08 in/s) |
Measuring range | 4 dm3/min to 1100 m3/h (1 to 4850 gal/min) |
Max. process pressure | PN 40, Class 300, 20K |
Medium temperature range |
Liner material PFA: –20 to +150 °C (–4 to +302 °F) Liner material PTFE: –40 to +130 °C (–40 to +266 °F) |
Ambient temperature range |
Flange material carbon steel: –10 to +60 °C (+14 to +140 °F) Flange material stainless steel: –40 to +60 °C (–40 to +140 °F) |
Sensor housing material | AlSi10Mg, coated |
Transmitter housing material | AlSi10Mg, coated |
Degree of protection | IP66/67, type 4X enclosure |
Display/Operation |
4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available |
Outputs |
4‐20 mA HART (passive) Pulse/frequency/switch output (passive) |
Inputs | None |
Digital communication | HART, PROFIBUS PA, FOUNDATION Fieldbus |
Power supply | DC 18 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output) |
Hazardous area approvals |
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, JPN, UK Ex |
Other approvals and certificates |
Product safety CE, C-Tick |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates |
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
Pressure approvals and certificates | CRN, PED |
Material certificates | 3.1 material |
Hygienic approvals and certificates | Drinking water approvals: ACS, NSF 61 |
Documents