Endress+Hauser
Highly Accurate Ultrasonic Flowmeter Proline Prosonic Flow 92F
- SKU:
- Highly Accurate Ultrasonic Flowmeter Proline Prosonic Flow 92F
- Weight:
- 0.00 Grams
Description
Application
The Prosonic Flow F is an inline sensor designed with a robust industrial build for precise ultrasonic fluid measurement. Paired with the loop-powered Prosonic Flow 92 transmitter, it delivers seamless system integration and high accuracy at a competitive price point. The Prosonic Flow 92F is particularly suitable for applications in the chemical and petrochemical sectors.
The measurement principle is unaffected by variables such as pressure, density, temperature, conductivity, and viscosity.
It is an ideal solution for measuring homogeneous conductive and non-conductive liquids in chemical and petrochemical processes.
Device Features:
- Fully compliant with NACE MR0175 and MR0103 standards.
- Available in nominal diameters ranging from DN 25 to 300 (1" to 12").
- Suitable for medium temperatures between –40 and 200 °C (–40 to 392 °F).
- Available in both compact and remote versions.
- Features a 2-line backlit display with push-button operation.
- Supports HART, PROFIBUS PA, and FOUNDATION Fieldbus communication protocols.
Benefits
- Reliable design for process industries: Approved for international hazardous areas.
- No additional pressure loss: Thanks to its full-bore design.
- Enhanced process transparency: Equipped with diagnostic capabilities.
- Simplified installation and cost savings: Due to the loop-powered transmitter.
- Comprehensive industry compliance: Adheres to IEC, ATEX, FM, CSA, JPN, and NEPSI standards.
- Efficient servicing: With automatic data recovery for maintenance purposes.
SPECIFICATIONS
Pressure Specifications
Measuring principle | Ultrasonic flow |
Product headline |
Higly accurate, loop-powered flowmeter with innovative parallel path design for minimum inlet runs. Inline device for homogeneous conductive and non-conductive liquids in the chemical and petrochemical industry. |
Sensor features |
Safe design for process industries – international hazardous area approvals. No additional pressure loss – full-bore design. Process transparency – diagnostic capability. Full compliance according to NACE MR0175 and MR010. Nominal diameter: DN 25 to 300 (1 to 12"). Medium temperature: –40 to 200 °C (–40 to 392 °F). |
Transmitter features |
Easy installation and reduced installation costs – loop-powered transmitter. Fully industry compliant – IEC/ATEX/FM/CSA/JPN/NEPSI. Automatic recovery of data for servicing. Device as compact or remote version. 2-line backlit display with push buttons. HART, PROFIBUS PA, FOUNDATION Fieldbus. |
Nominal diameter range |
2 path version: DN80 to 300 (3 to12") 3 path version: DN25 to 50 (1 to 2") 4 path version: DN 80 to 300 (3 to 12") |
Wetted materials |
Sensor: A351-CF3M (DN25 to 100) 1.4404/TP316/TP316L or A106 GrB (DN150 to 300) Transducer: 1.4404/316/316L Flanges : 1.4404/316/316L or A105/1.0432 |
Measured variables | Volume flow, calculated mass flow, sound velocity, flow velocity, signal strength |
Max. measurement error |
Volume flow (standard): - ±0.5 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s) Volume flow (option): - ±0.3 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s) |
Measuring range | 0.5 to 10 m/s (1.6 to 33 ft/s) |
Max. process pressure | PN 40 / ASME Cl. 300 / JIS 20K |
Medium temperature range |
-40 to +150 °C (-40 to +302 °F) -40 to +200 °C (-40 to +392 °F) optional |
Ambient temperature range |
-40 to +60 °C (-40 to +140 °F) compact -40 to +80 °C (-40 to +176 °F) remote sensor -40 to +60 °C (-40 to +140 °F) remote transmitter |
Transmitter housing material | AlSi10Mg, coated |
Degree of protection |
IP67, type 4X enclosure IP68 type 6P enclosure (option for remote) |
Display/Operation | 2 lines backlit display with 3 push buttons |
Outputs |
1x 4-20 mA HART 1x Pulse/frequency/switch output (passive) |
Inputs | N/A |
Digital communication | HART, FOUNDATION Fieldbus |
Power supply | 2 wire loop powered |
Hazardous area approvals | ATEX,FM, CSA, JPNm UK Ex |
Other approvals and certificates |
3.1 material (wetted parts), calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), CRN, AD2000 PED, EAC marking |
Product safety | EAC marking |
Metrological approvals and certificates | calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) |
Pressure approvals and certificates | CRN, PED, AD2000 |
Material certificates | 3.1 material (wetted parts) |
Documents
You may want to read this product's catalog. If so, please click to view the Endress+Hauser Proline Prosonic Flow 92F Series datasheet.