Endress+Hauser
Hydrostatic Level measurement Deltapilot FMB52
- SKU:
- Hydrostatic Level measurement Deltapilot FMB52 Series
- Weight:
- 0.00 Grams
Description
Application
The Deltapilot FMB52, featuring a cable design with a fixed process connection, is equipped with a Contite measuring cell and is primarily utilized in the process and environmental industries. It is ideal for measuring levels in liquids and paste-like substances within both open and closed containers, with no impact from potential foam formation. Additionally, it is suitable for use in SIL2 safety systems.
Key Applications:
- Level measurement in various media
Process Connections:
- Threads and flanges
Temperature Ranges:
- PE cable: -10 to +70°C (+14 to +158°F)
- FEP cable: -10 to +80°C (+14 to +176°F)
Measuring Range:
- 0.1 to 10 bar / 100 m H2O (1.5 to 150 psi / 300 ft H2O)
Accuracy:
- Standard: ±0.2%
- Optional: ±0.1%
The device also comes with international explosion protection certifications, overfill prevention according to WHG, SIL compliance, and approval for use with drinking water.
Benefits
The Deltapilot FMB52 offers several advantages:
- Reliable Performance: Features a hermetically sealed Contite measuring cell that is resistant to condensate, ensuring high reference accuracy of ±0.2%, with an optional upgrade to ±0.1%, and minimal temperature-related effects.
- Modular Design: Allows for easy replacement of the display or electronics, enhancing the flexibility and longevity of the device.
- Versatile Integration: Seamlessly integrates into various systems (HART/PA/FF) without dependency on specific platforms.
- User-Friendly Operation: Provides simple and safe operation through menu guidance, accessible on-site via the display module, or remotely via 4 to 20mA with HART, PROFIBUS PA, or FOUNDATION Fieldbus.
Global Compliance: Supports international deployment with a broad range of approvals, ensuring compatibility with various industry standards
SPECIFICATIONS
Pressure Specifications
Continuous / Liquids Specifications
Measuring principle
|
Hydrostatic pressure
|
Characteristic |
Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell: Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences Cable version
|
Supply voltage
|
4...20 mA HART 10,5...45 VDC (Non Ex): Ex ia: 10,5...30 VDC PROFIBUS PA: 9...32 VDC (Non Ex) FOUNDATION Fieldbus: 9...32 VDC (Non Ex)
|
Reference Accuracy
|
Standard 0.2% Optional 0.1%
|
Long term stability
|
0.05 % of URL/year
|
Process temperature
|
PE cable: -10°C…70°C / 14°F…158°F FEP cable: -10°C…80°C / 14°F…176°F
|
Ambient temperature
|
-40°C...85°C (-40°F...185°F)
|
Measuring cell
|
100 mbar...10 bar (1.5 psi...150 psi)
|
Smallest calibratable span
|
10 mbar (1.45 psi)
|
Vacuum resistance
|
0 mbar abs.
|
Max. Turn down
|
100:1
|
Max. overpressure limit
|
40 bar (600 psi)
|
Process connection
|
Thread: G1 1/2, MNPT1 1/2 Flange: DN40...DN100, ASME 2"...4", JIS 10K
|
Material process membrane
|
316L, AlloyC, Gold-Rhodium PE, FEP
|
Material gasket
|
Viton, EPDM, Kalrez, none
|
Fill fluid
|
Inert oil, Synthetic oil
|
Material housing
|
316L, Die-cast aluminum
|
Communication
|
4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus
|
Certificates / Approvals
|
ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex
|
Safety approvals
|
Overfill protection WHG SIL
|
Marine approvals
|
GL/ ABS/ LR/ BV/ DNV
|
Specialities
|
Modularity to differential pressure and process pressure devices (replacable display, universal electronics) Diagnostic functions
|
Drinking water approvals
|
KTW/ NSF/ ACS
|
Design approvals
|
EN10204-3.1 NACE MR0175
|
Measuring principle
|
Hydrostatic
|
Characteristic / Application
|
Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell: Hermetically sealed, condensate-resistant and climatic-proofed Cable version
|
Specialities |
Modularity to differential pressure and process pressure devices (replacable display, universal electronics) diagnostic functions Hermetically sealed Contite measuring cell (condensate-resistant and climatic-proofed)
|
Supply / Communication
|
4...20mA HART: 10,5...45V DC Ex ia: 10,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC (Non Ex)
|
Accuracy |
Standard 0.2% Optional 0.1%
|
Long term stability
|
0.05 % of URL/year
|
Ambient temperature
|
-40°C...85°C (-40°F...185°F)
|
Process temperature
|
PE cable: -10°C…70°C / 14°F…158°F FEP cable: -10°C…80°C / 14°F…176°F
|
Process pressure / max. overpressure limit
|
40 bar (600 psi)
|
Pressure measuring range
|
100 mbar...10 bar (1.5 psi...150 psi)
|
Main wetted parts
|
Alloy C 316L Cable (PE/FEP) optional coating AuPt optional coating AuRh
|
Process connection
|
Thread: G1 1/2, MNPT1 1/2 Flange: DN40...DN100, ASME 2"...4", JIS 10K
|
Max. measurement distance
|
100 m (328 ft) H2O
|
Communication
|
4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus
|
Certificates / Approvals
|
ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI
|
Safety approvals
|
Overfill protection WHG SIL
|
Design approvals
|
EN10204-3.1 NACE MR0175
|
Marine approval
|
GL/ ABS/ LR/ BV/ DNV
|
Drinking water approvals
|
KTW/ NSF/ ACS
|
Options
|
Separate housing Initial device settings Overvoltage protection
|
Application limits
|
If pressurized, usage of two pressure transmitters to measure the differential pressure (electronic dP) Observe ratio head pressure : hydrostatic pressure In case of an open tank or shaft use FMB53 with mounting clamp.
|
Documents
You may want to read this product's catalog. If so, please click to view the Endress+Hauser Hydrostatic Level measurement Deltapilot FMB52 Series datasheet.