The Deltapilot FMB70, equipped with a condensate-resistant Contite measuring cell and a dual-chamber housing, is ideal for both process and hygienic applications. It is specifically designed for level measurement in liquid and paste-like media within open or closed containers, and it operates reliably even in the presence of foam. The built-in HistoROM/M-DAT data module simplifies the management of process and device parameters. This device is designed in compliance with IEC 61508, making it suitable for use in SIL3 safety systems.
It can be utilized for both level and pressure measurement.
- Process connections: Threads, flanges, and hygienic connections
- Temperature range: –10 to +100°C (14 to 212°F), with short-term tolerance up to +135°C (275°F) for 30 minutes
- Measuring range: 0.1 to 10 bar relative (1.5 to 150 psi)
- Accuracy: ±0.075%
This device comes with international explosion protection certifications, overfill prevention in accordance with WHG, SIL certification, hygienic approvals, and marine certifications.
Benefits
The Contite measuring cell is hermetically sealed and resistant to condensate, offering high reference accuracy of ±0.1%, or optionally ±0.075%, with minimal temperature effects due to active temperature compensation. The Deltapilot FMB70 ensures exceptional batch-to-batch repeatability and long-term stability.
Its modular design allows for easy replacement of the display or electronics, while the HistoROM/M-DAT data module ensures secure backup of instrument settings and measured values. The device is functionally monitored from the measuring cell to the electronics and allows for seamless integration into any system (HART/PA/FF). Additionally, it is suitable for international use, supported by a wide range of certifications and approvals.
SPECIFICATIONS
Pressure Specifications
Measuring principle
|
Hydrostatic pressure
|
Characteristic
|
Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell: Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences Compact version
|
Supply voltage
|
4...20 mA HART 10,5...45 VDC (Non Ex): Ex ia: 10,5...30 VDC PROFIBUS PA: 9...32 VDC (Non Ex) FOUNDATION Fieldbus: 9...32 VDC (Non Ex)
|
Reference Accuracy
|
Standard 0.1% Optional 0.075%
|
Long term stability
|
0.05 % of URL/year
|
Process temperature
|
-10°C...100°C (14°F...212°F)
|
Ambient temperature
|
-40°C...85°C (-40°F...185°F)
|
Measuring cell
|
100 mbar...10 bar (1.5 psi...150 psi)
|
Smallest calibratable span
|
25 mbar (3.63 psi)
|
Vacuum resistance
|
0 mbar abs. |
Max. overpressure limit
|
40 bar (600 psi)
|
Process connection
|
Thread: G1 1/2, MNPT1/2 Flange: DN40...DN100, ASME 1 1/2"...4", JIS 10K
|
Process connection hygienic
|
Tri-Clamp DIN11851 DIN11864-1 NEUMO Varivent N SMS DRD
|
Material process membrane
|
316L, AlloyC, Gold-Rhodium
|
Material gasket
|
None, measuring cell welded
|
Fill fluid
|
Inert oil, Synthetic oil
|
Material housing
|
316L, Die-cast aluminum |
Communication |
4 ... 20 mA HART PROFIBUS PA FOUNDATION Fieldbus
|
Certificates / Approvals
|
ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC, UK Ex |
Safety approvals
|
SIL
|
Design approvals
|
EN10204-3.1 NACE MR0175 MR0103
|
Hygienic approvals
|
3A, EHEDG CoC ASME-BPE
|
Marine approvals
|
GL, DNV
|
Drinking water approvals
|
NSF
|
Specialities
|
Gold-rhodium coated membrane
|
Continuous / Liquids Specifications
Measuring principle
|
Hydrostatic |
Characteristic / Application
|
Compact pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell: Hermetically sealed, condensate-resistant and climatic-proofed
|
Specialities
|
Diagnostic functions |
Supply / Communication
|
4...20mA HART: 10,5...45V DC Ex ia: 10,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC (Non Ex)
|
Accuracy
|
Standard 0.1% Optional 0.075%
|
Long term stability
|
0.05 % of URL/year |
Ambient temperature
|
-40°C...+85°C (-40°F...+185°F)
|
Process temperature
|
-10°C...+100°C (+14°F...+212°F)
|
Process pressure / max. overpressure limit
|
40 bar (600 psi)
|
Pressure measuring range
|
100 mbar...10 bar (1.5 psi...150 psi)
|
Main wetted parts
|
Alloy C 316L
|
Process connection
|
Thread: G1 1/2, MNPT1/2 Flange: DN40...DN100, ASME 1 1/2"...4", JIS 10K
|
Process connection hygienic
|
Tri-Clamp DIN11851 DIN11864-1 NEUMO Varivent N SMS DRD
|
Max. measurement distance
|
100 m (328 ft) H2O
|
Communication
|
4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus
|
Certificates / Approvals
|
ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC
|
Safety approvals
|
SIL
|
Design approvals
|
EN10204-3.1 NACE MR0175, MR0103
|
Hygienic approvals
|
3A, EHEDG CoC ASME-BPE
|
Marine approval
|
GL/ DNV |
Drinking water approvals
|
NSF |
Options |
HistoROM/M-Dat 4-line digital display SS- or Aluminiumhousing Separate housing
|
Application limits
|
Measuring cell: Contite, condensate-proof, watertight, metal welded If pressurized, possibly use differential pressure measurement with two pressure transmitters. Observe ratio head pressure : hydrostatic Pressure
|
Documents