null
Endress+Hauser

Hygienic Coriolis Flowmeter Proline Promass S 300

(No reviews yet) Write a Review
SKU:
Proline Promass S 300 Series
MPN:
Proline Promass S 300
Weight:
0.00 Grams
+971 4 259 5133

Description

Application

The Promass S is designed with a focus on hygienic standards, making it ideal for applications in the food and beverage industry where cleanability is crucial. Its self-draining, single-tube construction ensures gentle handling of fluids. The compact Promass S 300 transmitter offers enhanced flexibility for both operation and system integration, with features like one-sided access, remote display, and advanced connectivity options. Equipped with Heartbeat Technology, it ensures continuous process safety. The measuring principle works independently of fluid properties like viscosity and density, making it suitable for applications that demand optimal cleanability under hygienic conditions.

Device Properties:

  • Wide selection of hygienic process connections
  • Compliant with 3-A and EHEDG standards
  • Quick recovery from CIP/SIP procedures
  • Compact, dual-compartment housing with up to three I/O options
  • Backlit display with touch control and WLAN access
  • Optional remote display available

Benefits

  • Enhanced process safety with a fully cleanable, self-drainable tube design
  • Reduced need for multiple measurement points due to multivariable measurement capabilities (flow, density, temperature)
  • Space-efficient installation with no need for inlet/outlet runs
  • Full access to process and diagnostic data through numerous configurable I/Os and Ethernet connectivity
  • Simplified setup with freely configurable I/O functionality
  • Built-in verification via Heartbeat Technology for continuous system monitoring

Documents

You may want to read this product's catalog. If so, please click to view the Proline Promass S 300 Series datasheet.

SPECIFICATIONS

Liquids Specifications

Measuring principle Coriolis
Product headline Easy‐to‐clean, self‐drainable single‐tube system with a compact, easily accessible transmitter.
Dedicated to applications requiring optimal cleanability under hygienic conditions.
Sensor features Increased process safety – easily cleanable and fully self-drainable tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Large range of hygienic process connections. 3-A and EHEDG conform. Fast recovery from CIP/SIP.
Transmitter features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Compact hygienic dual-compartment housing with IP69 and up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.
Nominal diameter range DN 8 to 50 (⅜ to 2")
Wetted materials Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 70,000 kg/h (0 to 2,570 lb/min)
Max. process pressure PN 40, Class 150, 20K
Medium temperature range –50 to +150 °C (–58 to +302 °F)
Ambient temperature range Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material AlSi10Mg, coated; stainless steel for hygienic transmitter design
Degree of protection IP66/67, type 4X enclosure
IP69
Display/Operation 4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
Outputs 3 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Inputs Status input
4-20 mA input
Digital communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Power supply DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC
Product safety CE, C-Tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Pressure approvals and certificates PED, CRN
Material certificates 3.1 material
Hygienic approvals and certificates 3-A, EHEDG, cGMP

Gas Specifications

Measuring principle Coriolis
Sensor features Increased process safety – easily cleanable and fully self-drainable tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Large range of hygienic process connections. 3-A and EHEDG conform. Fast recovery from CIP/SIP.
Hygienic approvals and certificates cGMP

Density Specifications

Measuring principle Coriolis
Product headline Easy‐to‐clean, self‐drainable single‐tube system with a compact, easily accessible transmitter.
Dedicated to applications requiring optimal cleanability under hygienic conditions.
Sensor features Increased process safety – easily cleanable and fully self-drainable tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Large range of hygienic process connections. 3-A and EHEDG conform. Fast recovery from CIP/SIP.
Transmitter features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Compact hygienic dual-compartment housing with IP69 and up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.
Nominal diameter range DN 8 to 50 (⅜ to 2")
Wetted materials Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 70,000 kg/h (0 to 2,570 lb/min)
Max. process pressure PN 40, Class 150, 20K
Medium temperature range –50 to +150 °C (–58 to +302 °F)
Ambient temperature range Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material AlSi10Mg, coated; stainless steel for hygienic transmitter design
Degree of protection IP66/67, type 4X enclosure
IP69
Display/Operation 4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
Outputs 3 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Inputs Status input
4-20 mA input
Digital communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Power supply DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC
Product safety CE, C-Tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Pressure approvals and certificates PED, CRN
Material certificates 3.1 material
Hygienic approvals and certificates 3-A, EHEDG, cGMP

Density/Concentration Specification

Measuring principle Coriolis
Product headline Easy‐to‐clean, self‐drainable single‐tube system with a compact, easily accessible transmitter.
Dedicated to applications requiring optimal cleanability under hygienic conditions.
Sensor features Increased process safety – easily cleanable and fully self-drainable tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Large range of hygienic process connections. 3-A and EHEDG conform. Fast recovery from CIP/SIP.
Transmitter features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Compact hygienic dual-compartment housing with IP69 and up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.
Nominal diameter range DN 8 to 50 (⅜ to 2")
Wetted materials Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 70,000 kg/h (0 to 2,570 lb/min)
Max. process pressure PN 40, Class 150, 20K
Medium temperature range –50 to +150 °C (–58 to +302 °F)
Ambient temperature range Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material AlSi10Mg, coated; stainless steel for hygienic transmitter design
Degree of protection IP66/67, type 4X enclosure
IP69
Display/Operation 4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
Outputs 3 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Inputs Status input
4-20 mA input
Digital communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Power supply DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC
Product safety CE, C-Tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Pressure approvals and certificates PED, CRN
Material certificates 3.1 material
Hygienic approvals and certificates 3-A, EHEDG, cGMP
View AllClose