null
Endress+Hauser

Hygienic Coriolis Flowmeter Proline Promass S 500

(No reviews yet) Write a Review
SKU:
Proline Promass S 500 Series
MPN:
Proline Promass S 500
Weight:
0.00 Grams
+971 4 259 5133

Description

Application

The Promass S flowmeter is designed with a focus on hygienic applications, particularly in the food and beverage industry where optimal cleanability is essential. Its self-drainable, single-tube system ensures gentle handling of fluids, making it ideal for sensitive processes. The innovative remote transmitter, Promass S 500, offers flexible installation and enhances operational safety, even in challenging environments. Additionally, the integrated Heartbeat Technology guarantees continuous process safety. The measuring principle is independent of fluid properties, such as viscosity or density, ensuring reliable performance across a wide range of conditions. Key Features:

  • Ideal for applications requiring stringent hygiene and cleanability
  • Wide variety of hygienic process connections
  • Compliant with 3-A and EHEDG standards
  • Fast recovery from CIP/SIP procedures
  • Remote version with up to 4 I/Os, and an IP69-rated hygienic sensor housing
  • Backlit display with touch control and WLAN access
  • Standard sensor-to-transmitter cable for ease of use

Benefits

  • Enhanced process safety: The self-drainable tube design ensures optimal cleanability.
  • Multifunctional measurement: Measures flow, density, and temperature, reducing the need for multiple instruments.
  • Space-efficient installation: No need for inlet or outlet runs, saving valuable space.
  • Comprehensive access to data: Multiple I/Os and Ethernet connectivity provide full access to process and diagnostic information.
  • Reduced complexity: Configurable I/O functionality simplifies system design and operation.
  • Built-in verification: Heartbeat Technology allows continuous monitoring and verification without interrupting operations.

Documents

You may want to read this product's catalog. If so, please click to view the Proline Promass S 500 Series datasheet.

SPECIFICATIONS

Liquids Specifications

Measuring principle Coriolis
Product headline Easy-to-clean device with self-drainable single-tube system, as remote version with up to 4 I/Os.
Dedicated to applications requiring optimal cleanability under hygienic conditions.
Sensor features Increased process safety – easily cleanable and fully self-drainable tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Large range of hygienic process connections. 3-A and EHEDG conform. Fast recovery from CIP/SIP.
Transmitter features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version with up to 4 I/Os; hygienic sensor connection housing with IP69. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.
Nominal diameter range DN 8 to 50 (⅜ to 2")
Wetted materials Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 70,000 kg/h (0 to 2,570 lb/min)
Max. process pressure PN 40, Class 150, 20K
Medium temperature range –50 to +150 °C (–58 to +302 °F)
Ambient temperature range Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): 1.4301 (304); 1.4404 (316L)
Transmitter housing material AlSi10Mg, coated; Polycarbonate
Degree of protection Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP69
Transmitter remote version: IP66/67, Type 4X enclosure
Display/Operation 4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Outputs 4 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Inputs Status input
4-20 mA input
Digital communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Power supply DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
Product safety CE, C-Tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Pressure approvals and certificates PED, CRN
Material certificates 3.1 material
Hygienic approvals and certificates 3-A, EHEDG, cGMP

Gas Specifications

Measuring principle Coriolis
Product headline Easy-to-clean device with self-drainable single-tube system, as remote version with up to 4 I/Os.
Dedicated to applications requiring optimal cleanability under hygienic conditions.
Sensor features Increased process safety – easily cleanable and fully self-drainable tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Large range of hygienic process connections. 3-A and EHEDG conform. Fast recovery from CIP/SIP.
Transmitter features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version with up to 4 I/Os; hygienic sensor connection housing with IP69. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.
Hygienic approvals and certificates cGMP

Density Specifications

Measuring principle Coriolis
Product headline Easy-to-clean device with self-drainable single-tube system, as remote version with up to 4 I/Os.
Dedicated to applications requiring optimal cleanability under hygienic conditions.

Density/Concentration Specification

Measuring principle Coriolis
Product headline Easy-to-clean device with self-drainable single-tube system, as remote version with up to 4 I/Os.
Dedicated to applications requiring optimal cleanability under hygienic conditions.
Sensor features Increased process safety – easily cleanable and fully self-drainable tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Large range of hygienic process connections. 3-A and EHEDG conform. Fast recovery from CIP/SIP.
Transmitter features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version with up to 4 I/Os; hygienic sensor connection housing with IP69. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.
Nominal diameter range DN 8 to 50 (⅜ to 2")
Wetted materials Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 70,000 kg/h (0 to 2,570 lb/min)
Max. process pressure PN 40, Class 150, 20K
Medium temperature range –50 to +150 °C (–58 to +302 °F)
Ambient temperature range Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): 1.4301 (304); 1.4404 (316L)
Transmitter housing material AlSi10Mg, coated; Polycarbonate
Degree of protection Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP69
Transmitter remote version: IP66/67, Type 4X enclosure
Display/Operation 4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Outputs 4 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Inputs Status input
4-20 mA input
Digital communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Power supply DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
Product safety CE, C-Tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Pressure approvals and certificates PED, CRN
Material certificates 3.1 material
Hygienic approvals and certificates 3-A, EHEDG, cGMP
View AllClose