null
Endress+Hauser

Hygienic Point Level Switch Liquiphant FTL63

(No reviews yet) Write a Review
SKU:
Hygienic Point Level Switch Liquiphant FTL63 series
Weight:
0.00 Grams
Call us: +971 4 259 5133

Description

Application

The Liquiphant FTL63 is specifically designed to meet the rigorous hygienic standards of the food and beverage, as well as life sciences industries. Utilizing advanced vibronic technology, it delivers reliable performance in all pumpable liquids, even in challenging conditions where other measurement methods fail due to varying conductivity, dielectric constant (DC value), deposits, foam, turbulence, or air bubbles. This makes it an ideal replacement for float switches, capacitive, or optical sensors.

The Liquiphant FTL63 is well-suited for point level detection in process and storage tanks, as well as pipelines.

  • Operates in process temperatures ranging from -50 to +150 °C (-58 to +302 °F)
  • Handles viscosities up to 10,000 mm²/s (cSt)
  • Sensor lengths available up to 3 m (10 ft)
  • Surface finishes include both mechanical and electropolished options
  • Certified for international hygienic standards (3-A, EHEDG, ASME BPE), with material conformity adhering to EC1935/2004, FDA, and GB4806 regulations
  • International explosion protection certificates, WHG overfill protection, and SIL compliance
  • Supports CIP/SIP cleaning processes

 


Benefits

  • Suitable for universal application in all pumpable liquids without the need for media adjustments, leveraging proven vibronic measurement technology
  • Ensures high levels of process and product safety through a certified hygienic design (3-A, EHEDG, ASME BPE) and verified material conformity with complete traceability, backed by certifications (EC1935/2004, FDA, and cGMP)
  • Simplifies commissioning with plug-and-play functionality and reduces maintenance requirements, featuring a test button or magnetic pin for easy function testing
  • Offers continuous diagnostics and traceable, documented verification on-demand without interrupting the process, thanks to Heartbeat Technology
  • Allows for intuitive operation through Bluetooth® technology and provides visual process status updates via a bright, color-coded LED display

 

SPECIFICATIONS

Pressure Specifications

Measuring principle Vibration Liquids

Characteristic / Application

Premium device for point level detection

in hygienic/aseptic applications.

Focus Food & Beverage and Life Sciences.

Compact sensor version with an optional pipe extension up to 3 m (9,85 ft).

Modular housing concept.

Wide range of certificates.

Specialities

Plug and play functionalities,

Heartbeat Technology,

LED Module,

Bluetooth® Operation and maintenance,

Surface finish: mechanical or electro-polished,

Density/Concentration measurement,

SIL 2/3 according to IEC 61508.

Supply / Communication

19 ..253V AC,

10...55V DC-PNP,

9...20V DC with relay DPDT,

19...253V AC or 19...55V DC with relay DPDT,

8/16mA HART,

NAMUR,

PFM

Ambient temperature

-50 °C...+70 °C

(-58 °F...+158 °F)

Process temperature

-50 °C...+150 °C

(-58 °F...+302 °F)

Process pressure / max. overpressure limit

Vacuum...64 bar

(Vacuum...928 psi)

Min. density of medium

0.5 g/cm³

(0.4 g/cm³ optional)

Main wetted parts 316L
Process connection

Threads (for weld-in adapter):

G3/4A, G1A

Process connection hygienic

Tri-Clamp,

DIN 11851, DIN11864-1

Ingold,

Flush mount,

DRD,

SMS1145,

Varivent (Varinline)

Sensor length

Compact sensor

Short tube (Liquiphant II)

148mm…3000mm (6,00…118")

Communication

HART

Bluetooth® wireless technology

Certificates / Approvals

ATEX, IEC Ex, CSA C/US, JPN Ex, KC Ex,

INMETRO Ex, NEPSI Ex/CCC, UK Ex

 Safety approvals  Overfill protection WHG;

SIL 2/ SIL 3

 Design approvals  Inspection certificate 3.1, EN10204,

CoC ASME BPE,

Conformity to cGMP,

EU Food Contact Material (EC) 1935/2004,

US Food Contact Material FDA CFR 21,

CN Food Contact Material GB 4806,

Declaration of Conformity ASME B31.3,

AD2000,

CRN approval

 Hygienic approvals  3-A,

EHEDG,

CoC-ASME BPE

 Options  LED module,

Bluetooth module,

Graphic touch display,

Customized settings,

Weld-in adapter

 Components  FTL325P Interface PFM

FTL325N Interface NAMUR

FML621 Density controller

 Density Specifications

Measuring principle Vibration Density
Product Headline

Hygienic point level switch for liquids.

Point level detection in process and storage tanks as well as in pipelines in hygienic and aseptic applications.

Characteristic / Application

Premium device for density measurement in hygienic/aseptic applications.

Focus Food & Beverage and Life Sciences.

Compact sensor version with an optional pipe extension up to 3 m (9,85 ft).

Modular housing concept.

Wide range of certificates

Supply / Communication

via density controller FML621

Ambient temperature

-40 °C...+70 °C

(-40...+158 °F)

Process temperature 0...+80 °C (+32…+176 °F)
Process pressure 0...25 bar (0…362 psi)
Wetted parts

316L

Hygienic

3-A,

EHEDG,

CoC-ASME BPE

Sensor length

Compact sensor

Short tube (Liquiphant II)

148mm…3000mm (6,00…118")

Output Pulse

Certificates / Approvals

ATEX, IEC Ex, CSA C/US, JPN Ex, KC Ex,

INMETRO Ex, NEPSI Ex/CCC, UK Ex

Specialities

Density/Concentration measurement in

combination with density controller FML621,

Surface finish: mechanical polished (up to 0.3 µm)

Components Density Computer FML621

 

Documents

You may want to read this product's catalog. If so, please click to view the Endress+Hauser Liquiphant FTL63 – hygienic point level switch for liquids Series datasheet.
View AllClose