null
Endress+Hauser

Insertion Flowmeter with Remote Transmitter Proline Prosonic Flow I 400

(No reviews yet) Write a Review
SKU:
Proline Prosonic Flow I 400 Series
MPN:
Proline Prosonic Flow I 400
Weight:
0.00 Grams
+971 4 259 5133

Description

Application

The Prosonic Flow I 400 combines insertion sensor technology with the advanced features of our Proline 400 transmitters, such as Heartbeat Technology for reliable process monitoring and integrated web server access for straightforward installation and operation. Welded directly into the pipe wall, the Prosonic Flow I 400 is particularly well-suited for large pipelines, such as those used in water distribution systems and projects requiring a fixed installation. The measurement principle is independent of fluid density and conductivity, enabling bidirectional flow measurement for water and wastewater applications. Device properties:

  • Supports two parallel measurement paths
  • Suitable for large diameters: DN 200 to 4000 (8 to 160")
  • Medium temperature range: –40 to +80 °C (–40 to +176 °F)
  • Transmitter housing available in durable polycarbonate or aluminum
  • Remote version for wall mounting
  • Integrated data logger for monitoring measured values

Benefits

  • Low capital investment: Cost-effectiveness increases with larger pipe diameters (up to DN 4000/160")
  • Long-term stable signal: Maintenance-free direct installation of the sensor in the medium
  • Process transparency: Advanced diagnostic capabilities
  • Safe operation: No need to open the device, thanks to a display with touch control and background lighting
  • Full remote access: Convenient web server integration
  • Integrated diagnostics, verification, and monitoring: Heartbeat Technology ensures continuous reliability

SPECIFICATIONS

Liquids Specifications

 

 

 Measuring principle

 

 

Ultrasonic flow

 

 

Product headline

 

 

Insertion meter with Heartbeat Technology and web server for the water and wastewater industry.

Bidirectional flow measurement of water and wastewater.

 

 

Sensor features

 

 

Low capital investment – cost-effectiveness increases with pipe diameter (up to DN 2000/80"). Long-term stable signal – maintenance-free permanent mounting from outside with coupling pads. Process transparency – diagnostic capability.

Supports two parallel measurement paths. For large diameters: DN 200 to 4000 (8 to 160"). Medium temperatur: –40 to +80 °C (–40 to +176 °F).

 

 Transmitter features  

Safe operation – no need to open the device due to display with touch control, background lighting. Full remote access – web server. Integrated diagnostics, verification and monitoring – Heartbeat Technology.

Transmitter housing made of durable polycarbonate or aluminium. Remote version for wall mounting. Integrated data logger: measured values monitoring.

 

 

Nominal diameter range

 

 

DN200 to 4000 (8 to 160")

 

 

Wetted materials

 

 

Insertion system:

Sensor holder 1.4301 (304), 1.4404 (316L)

Sensor housing 1.4301 (304), 1.4404 (316L)

 

 

Measured variables

 

 

Volume flow, Flow velocity, Sound velocity

 

 

Max. measurement error

 

 

Volume flow: ±2% o.r. above DN200

 

 

Measuring range

 

 

0 to 15 m/s (0 to 50 ft/s)

 

 

Max. process pressure

 

 

N/A

 

 

Medium temperature range

 

 

–40 to +80 °C (–40 to +176 °F)

 

 

Ambient temperature range

 

 

-20 to 60°C (-4 to 140°F)

 

 

Sensor housing material

 

 

N/A

 

 

Transmitter housing material

 

 

Wall-mounted housing:

Polycarbonat; AlSi10Mg, coated

 

 

Degree of protection

 

 

Transmitter: IP66/67, Type 4X enclosure

Sensor: IP66/67, Type 4X enclosure, IP68, Type 6P enclosure (optional)

 

Display/Operation

 

4‐line backlit display with touch control (operation from outside)

Configuration via local display, web browser and operating tools possible

 

Outputs

 

3 ouputs:

4‐20 mA/4‐20 mA HART (active)

Pulse/frequency/switch output (passive)

Pulse/frequency/switch output (passive)

 

Inputs

 

 

Status input

 

 

Digital communication

 

 HART
 

Power supply

 

 

AC 100 to 240 V / AC/DC 24 V

Approvals

 

cCSAus

 

 

Other approvals and certificates

 

 

Other approvals and certificates

 

 

Product safety

 

 

CE, C-tick marking, EAC-marking

Metrological approvals and certificates

 

 

 Flowmeter verification

 

 

Verification performed on accredited calibration facilities (acc. to ISO/IEC 17025)

Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a

 

Marine approvals and certificates

 