Endress+Hauser
Intrinsically Safe Temperature Sensor: iTHERM ModuLine TM131
- SKU:
- Intrinsically Safe Temperature Sensor: iTHERM ModuLine TM131 series
- Weight:
- 0.00 Grams
Description
Application
The iTHERM ModuLine TM131 is an intrinsically safe temperature sensor (available as RTD or TC assembly) designed for use with either a custom-manufactured thermowell or an existing one. It can be equipped with an optional head transmitter that supports all major communication protocols, including Bluetooth® technology. Special features such as the iTHERM QuickNeck for effortless, tool-free recalibration, along with vibration-resistant and rapid-response sensor and thermowell technologies (iTHERM StrongSens, QuickSens), ensure superior measurement accuracy and reliability. The sensor is suitable for a wide range of applications, with a measuring range from –200 to +1,100 °C (–328 to +2,012 °F), pressure resistance up to 100 bar (1,450 psi), and a protection rating of up to IP68. The sensor elements are highly vibration-resistant, enduring up to 60g. The design also enhances maintenance efficiency, allowing for sensor replacement without process interruption and safe, straightforward recalibration of the measurement point.
Benefits
- Enhanced Safety: A second process barrier with failure indication provides valuable health status information, ensuring greater safety.
- iTHERM QuickSens: Achieves the fastest response times of 1.5 seconds, enabling optimal process control.
- iTHERM StrongSens: Offers unmatched vibration resistance (> 60g), contributing to maximum plant safety.
- iTHERM QuickNeck: Delivers cost and time savings through simple, tool-free recalibration.
- Optional Bluetooth® Connectivity: Facilitates wireless communication and configuration.
- Global Certification: Compliant with international explosion protection standards, including ATEX, IECEx, CSA C/US, and NEPSI.
SPECIFICATIONS
Thermometer Specifications
Measuring principle
|
Resistance Temperature Detector
|
Characteristic / Application
|
metric style modular temperature assembly universal range of application suitable for hazardous areas with neck or iTHERM QuickNeck incl. thermowell / protection tube (metal) or to be installed into thermowell can be used with iTHERM StrongSens, iTHERM QuickSens insert for fast response times
|
Thermowell / protection tube
|
welded protection tube or to be used with thermowell
|
Insert / probe
|
mineral insulated (MI), flexible
|
Outer diameter protection tube / Insert
|
Thermowell: 9x1,25 mm 11x2 mm 12x2,5 mm 14x2 mm 16x3,5 1/4" SCH80 1/2" SCH80 1/2" SCH40
|
Max. immersion length on request
|
up to 4.500,0 mm (177'')
|
Material protection tube/ thermowell
|
316 (1.4401) 316L (1.4404) 316Ti (1.4571) Alloy 600 (2.4816) Alloy C276 (2.4819) Alloy 446 (1.4749) Alloy 321 (1.4541) Sheath PTFE Sheath Tantal
|
Process connection
|
Male thread: G3/8, G1/2", G3/4", G1" NPT1/2", NPT3/4", NPT 1" M14x1.5, M18x1.5, M20x1.5, M27x2, M33x2 R1/2", R3/4" Female thread: M20x1.5, M24x1.5 NPT1/2" Cap-nut: M20x1.5, G1/2", G3/4" Compression fitting: NPT1/2", G1/2", G1" Flange: DN15 PN40 B1, C DN25 PN20, PN40, PN100 B1, B2, C DN40 PN40 B1 DN50 PN40 B1 ASME 1" 150 RF ASME 1" 300 RF ASME 1 1/2" 150 RF ASME 2" 150 RF ASME 2" 300 RF
|
Tip shape
|
straight reduced tapered optimized for quick response times
|
Surface roughness Ra
|
< 0.76 μm (0.03 μin)
|
Operating temperature range
|
PT100 TF iTHERM StrongSens: -50 °C ...500 °C (-58 °F ...932 °F) PT100 TF iTHERM QuickSens: -50 °C …200 °C (-58 °F …392 °F) PT100 WW: -200 °C ...600 °C (-328 °F ...1.112 °F) PT100 TF: -50 °C ...400 °C (-58 °F ...752 °F) Typ K: max. 1.100 °C (max. 2.012 °F) Typ J: max. 800 °C (max. 1.472 °F) Typ N: max. 1.100 °C (max. 2.012 °F)
|
Max. process pressure (static)
|
depending on the configuration up to 100 bar
|
Accuracy
|
Class AA acc. to IEC 60751 Class A acc. to IEC 60751 Class B acc. to IEC 60751 Class special or standard acc. to ASTM E230 Class 1 or 2 acc. to IEC 60584-2
|
Response time
|
fastest response time with thermowell t90 starting at below 10 s depending on configuration
|
Integration head transmitter
|
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
|
Ex - approvals
|
ATEX ATEX IECEx NEPSI IECEx EAC Ex CSA C/US INMETRO
|
Certification
|
SIL, MID, DNV/GL
|
Documents
You may want to read this product's catalog. If so, please click to view the Endress+Hauser Intrinsically Safe Temperature Sensor: iTHERM ModuLine TM131 series datasheet.