Description
Datexel Isolated Module Multiple Input, Current Output - DAT3011
1 SSR Digital Output + 2 SPST Relay Outputs, Watch-Dog Alarm, UL/CE Mark – Italian Made
The DAT 3011 device is able to acquire RTD or Tc sensors, mV, V or mA input signals connected to the universal analogue input in engineering units in digital format.
Moreover, it is available a second isolated analogue input for V or mA. The device is able to acquire up to 3 digital inputs and to drive one solid-state relay and two SPST relays. The Data are transmitted with MODBUS RTU/MODBUS ASCII protocol on the RS-485 network.
The device guarantees high accuracy and a stable measure versus time and temperature. To ensure the plant safety two Watch-Dog timer alarms are provided.
The isolation between the parts of circuit removes eventual ground-loop effects, allowing the use of the device even in the heavy environmental conditions.
The DAT 3011 is in compliance with the Directive UL 61010-1 for US market and with the Directive CSA C22.2 No 61010-1 for the Canadian market.
The device is housed in a rough self-extinguishing plastic container which, thanks to its thin profile of 22.5mm only, allows a high density mounting on EN-50022 standard DIN rail.
Datexel Isolated Module DAT3011 features are as follows:
- Field-Bus remote data acquisition
- Modbus Slave device on RS-485
- Modbus RTU/Modbus ASCII Protocol
- 1 Universal Analogue Input + 1 Analogue Input V/mA
- 2 Analogue Outputs 0-20mA
- 3 Digital Inputs with pulse counters up to 3 kHz
- 1 SSR Digital Output + 2 SPST Relay Outputs
- Watch-Dog Alarm
- Remotely Configurable
- 1500 Vac galvanic isolation on all the ways
- High Accuracy
- UL / CE mark
- DIN rail mounting in compliance with EN-50022
Datexel Isolated Module DAT3022 Input
- Voltage (mV, V)
- Thermocouple (J, K, S, R, B, E, T, N)
- RTD 2,3 wires Pt100-Pt1000-Ni100-Ni1000
- Resistance 2,3 wires
- Potentiometer
- Current 20 mA
OUTPUT
- Current 0 mA 20 mA
Data Transmission
- Baud Rate 115.2 kbps
- Max. distance 1.2 km – 4000 ft
DIGITAL INPUTS
- Number of Channels 3
- Pulse Counters (32 bit) 3 up to 3 kHz
- Input voltage OFF State: 0÷3 V
- (bipolar) ON State: 10÷30 V
- Input Impedance 4.7 kW
- Frequency Measure 1 Hz (min)÷200 Hz (max)
DIGITAL OUTPUTS
- N.1 SSR Output
- Voltage 30 Vac / 48 Vdc
- Current (resistive load) 0.4 A max
- N.2 Relays SPST
ISOLATION
- (Power supply - RS485 – Universal input – V, mA Input – Digital Inputs – Analogue Outputs) 1500 Vac, 50 Hz, 1 min
POWER SUPPLY
- Power supply voltage 18 .. 30 Vdc
- Reverse polarity protection 60 Vdc max
- Current consumption 100 mA max.
ENVIRONMENTAL CONDITIONS
- Operative Temperature -10°C .. +60°C
- UL Operative Temperature -10°C .. +40°C
- Storage Temperature -40°C.. +85°C
- Humidity (not condensed) 0 .. 90 %
- Maximum Altitude 2000 m
- Installation Indoor
- Category of installation II
- Pollution Degree 2
MECHANICAL SPECIFICATIONS
- Material Self-extinguish plastic
- IP Code IP20
- Wiring wires with diameter 0.8÷2.1 mm2 /AWG 14-18
- Tightening Torque 0.5 N m
- Mounting in compliance with DIN rail standard EN-50022
- Weight about 150 g.
CERTIFICATIONS
- EMC ( for industrial environments) Immunity EN 61000-6-2 Emission EN 61000-6-4
UL
- US Standard UL 61010-1
Series Information
“DAT3000 SERIES” data acquisition and control modules
The distributed I/O modules of the DAT3000 series represent a complete solution for the acquisition and control of the analog and digital I/O signals.
The series is composed of:
• Serial line converters and repeaters (DAT3580, DAT3580 USB, DAT3580 MBTCP, DAT3590).
• Modules for digital inputs and outputs (DAT3130, DAT3140, DAT3148/8, DAT3148/12, DAT3188/4, DAT3188/8).
• Modules for analog inputs (DAT3011, DAT3014, DAT3015, DAT3016, DAT3017, DAT3018, DAT3019).
• Modules with analog outputs (DAT3022, DAT3024, DAT3028).
The devices communicate on the RS-485 serial line by the MODBUS RTU communication protocol and are able to communicate with the host computer on multipoint net using only two wires.
About Datexel:
Founded in 1992 from the commitment and aspiration of several partners as a small provincial company, through the years DATEXEL has become an established reality on Italian and international markets as a manufacturer of electronic equipment for industrial automation and control process.
The range of DATEXEL products includes: Transmitters, signal and temperature Converters (both analogue and digital), galvanic Isolators, signal Splitters, I/O Modules, Trip Amplifiers, Power Supply Units, current loop Isolators, analogue and digital Displays.
Documents
To View Data Sheet for Datexel Isolated Module Multiple Input, Current Output - DAT3011 Please Click Here
Additional Information
RS485: |
Modbus RTU Slave |
Input: |
Multiple |
Channel 0: |
mV -100 to 100mV Volts -100mV to 10V Current 4-20mA, 0-20mA. RTD Pt100, Pt 1000, Ni100, Ni1000. Resistance 0-2000 Ohm Potentiometer 20-2000 Ohm Thermocouple J,K,R,S,B,E,T, N |
Channel 1: |
mV -100 to 100mV Volts -100mV to 10V Current 4-20mA, 0-20mA Digital |
Channel 1, 2 and 3: |
Off condition 0-3 V, On condition 10-30V |
Output: |
Analog |
Channel 1 and 2: |
Current 4-20mA Digital |
Channel 1: |
Solid Sate Relay |
Channel 2 and 3: |
SPST Relay 2 A 250Vac |
Power Supply: |
Voltage 9 - 30 Vdc. Reverse polarity protection 60 Vdc |
Current Consumption: |
60 mA up to 170 mA max |
Temperature rating: |
Operative Temperature -4°F +140°F -20°C +60°C Storage Temperature -40°F +185°F -40°C +85°C |
Humidity: |
(not condensing) 0-90% |
Housing: |
Material self-extinguishing |
Dimensions: |
W x L x H 3 3/4X 3 1/2 X 1 7/8 inch, 90 x 74 x 48mm |
Weight: |
150 g |
EMC: |
Immunity EN 61000-6-2 Emission EN 61000-6-4 |
Isolation: |
Between Modbus Master, Slave/Power supply 1500Vac, 50Hz, 1 Minute |
Configuration: |
PC Configurable |