Description
Datexel Isolated Module Thermocouple to RS485 Modbus - DAT3018
8 input channels, UL/CE mark, Watch-Dog Alarm, Galvanic Isolation – Great Quality
The DAT 3018 device is able to acquire up to 8 analogue input signals. The data are transmitted with MODBUS RTU/MODBUS ASCII protocol on the RS-485 network (RS-232 interface is available).
It is possible to connect on input thermocouples or voltage signals up to ± 1V . The Cold Junction compensation for thermocouples is internally performed.
The device guarantees high accuracy and stable measure versus time and temperature.
To ensure the plant safety, two Watch-Dog timer alarms are provided.
The isolation between the parts of circuit removes eventual ground-loop effects, allowing the use of the device even in the heavy environmental conditions.
The DAT 3018 is in compliance with the Directive UL 61010-1 for US market and with the Directive CSA C22.2 No 61010-1 for the Canadian market.
The device is housed in a rough self-extinguishing plastic container which, thanks to its thin profile of 17.5mm only, allows a high density mounting on EN-50022 standard DIN rail.
COMMUNICATION PROTOCOLS
The DAT3018 is designed to work with the MODBUS RTU/MODBUS ASCII protocol: standard protocol in field-bus; allows to directly interface DAT3000 series devices to the larger part of PLCs and SCADA applications available on the market.
The advantages and features for Datexel Isolated Module DAT3018
- Field-Bus remote data acquisition
- Modbus Slave device on RS-485
- Modbus RTU/ Modbus ASCII protocol
- 8 channels input
- Input configurable for Tc J, K, R, S, B, E, T, N and voltage up to ± 1V
- Watch-Dog Alarm
- Remotely Configurable
- 2000 Vac 3-ways Galvanic Isolation
- High Accuracy
- UL / CE mark
- DIN rail mounting in compliance with EN-50022
INPUT Datexel Isolated Module DAT3018
- Voltage (mV)
- Thermocouple (J, K, R, S, B, E, T, N)
Data Transmission
- Baud Rate 38.4 Kbps
- Max. distance 1.2 Km – 4000 ft
POWER SUPPLY
- Power supply voltage 10 .. 30 Vdc
- Reverse polarity protection 60 Vdc max
- Current Consumption 30 mA max
ISOLATION
- Input – RS485 2000 Vac 50 Hz, 1 min.
- Supply – Input 2000 Vac 50 Hz, 1 min.
- Supply – RS485 2000 Vac 50 Hz, 1 min.
Environmental Conditions
- Operative Temperature -10°C .. +60°C
- UL Operative Temperature -10°C .. +40°C
- Storage Temperature -40°C .. +85°C
- Relative humidity (not cond.) 0 ÷ 90 %
- Maximum Altitude 2000 m
- Installation Indoor
- Category of installation II
- Pollution Degree 2
Mechanical Specifications
- Material Self-extinguish plastic
- IP Code IP20
- Wiring wires with diameter 0.8÷2.1 mm2 /AWG 14-18
- Tightening Torque 0.8 N m
- Mounting in compliance with DIN rail standard EN-50022
- Weight about 150 g
EMC (for industrial environments)
- Immunity EN 61000-6-2
- Emission EN 61000-6-4
UL
- US Standard UL 61010-1
Series Information
“DAT3000 SERIES” data acquisition and control modules
The distributed I/O modules of the DAT3000 series represent a complete solution for the acquisition and control of the analog and digital I/O signals.
The series is composed of:
• Serial line converters and repeaters (DAT3580, DAT3580 USB, DAT3580 MBTCP, DAT3590).
• Modules for digital inputs and outputs (DAT3130, DAT3140, DAT3148/8, DAT3148/12, DAT3188/4, DAT3188/8).
• Modules for analog inputs (DAT3011, DAT3014, DAT3015, DAT3016, DAT3017, DAT3018, DAT3019).
• Modules with analog outputs (DAT3022, DAT3024, DAT3028).
The devices communicate on the RS-485 serial line by the MODBUS RTU communication protocol and are able to communicate with the host computer on multipoint net using only two wires
About Datexel:
Founded in 1992 from the commitment and aspiration of several partners as a small provincial company, through the years DATEXEL has become an established reality on Italian and international markets as a manufacturer of electronic equipment for industrial automation and control process.
The range of DATEXEL products includes: Transmitters, signal and temperature Converters (both analogue and digital), galvanic Isolators, signal Splitters, I/O Modules, Trip Amplifiers, Power Supply Units, current loop Isolators, analogue and digital Displays.
Documents
To View Data Sheet for Datexel Isolated Module Thermocouple to RS485 Modbus - DAT3018 Please Click HereAdditional Information
Input: |
Thermocouple (J, K, S, R, B, E, T, N) Voltage (mV) |
Voltage: |
-1 to 1Volt |
RS485: |
Modbus RTU Slave |
RS232: |
Modbus Slave |
Power Supply: |
10 - 30 Vdc. Reverse polarity protection 60 Vdc |
Current Consumption: |
30 mA |
Temperature rating: |
Operative Temperature -4°F +140°F -20°C +60°C Storage Temperature -40°F +185°F -40°C +85°C |
Humidity: |
(not condensing) 0-90% |
Housing: |
Material self-extinguishing |
Dimensions: |
W x L x H 3 3/4X 3 1/2 X 1 7/8 inch, 90 x 74 x 48mm |
Weight: |
160 g |
EMC: |
Immunity EN 61000-6-2 Emission EN 61000-6-4 |
Isolation: |
Between Modbus Master, Slave/Power supply 1500Vac, 50Hz, 1 Minute |
Configuration: |
PC Configurable |