null
Endress+Hauser

Manual or Automatic Retractable Assembly Cleanfit CPA472D

(No reviews yet) Write a Review
SKU:
Cleanfit CPA472D Series
MPN:
Cleanfit CPA472D
Weight:
0.00 Grams
+971 4 259 5133

Description

Application The Cleanfit CPA472D assembly is designed to withstand demanding process conditions. It offers a wide range of durable materials, ensuring safe sensor operation even in environments with high pressure, high temperatures, or aggressive media. This assembly enables sensor replacement without interrupting the process and supports automatic cleaning and calibration through an optional control system. Enjoy simplified, time-saving sensor management and extended sensor lifespan. The Cleanfit CPA472D is suitable for installation in tanks or pipes within the following industries:

  • Chemical industry
  • Power plants
  • Biodiesel production

It can handle pressures up to 10 bar.


Benefits

  • Exceptionally durable: Operates under pressures of up to 10 bar and temperatures reaching 140°C, including PEEK, PVDF, and conductive PVDF versions.
  • Superior chemical resistance for extended operational life.
  • Eliminates the need for process interruptions during electrode cleaning and calibration, reducing maintenance time and costs.
  • Versatile adaptability to various applications with a wide selection of materials and process connections.

Documents

You may want to read this product's catalog. If so, please click to view the Cleanfit CPA472D Series datasheet.

SPECIFICATIONS

pH Specification

Measuring principle Potentiometric
Application Chemical industry, biodiesel plants, power plants, plant design, tanks, process vats or pipes
Installation Retractable holder
Characteristic For tanks and process vats and pipelines or pipes (min. DN80)
The robust retractable assembly permits replacement of the electrode while the tank is full or under process conditions with pressures of up to 6 bar
Design Manual or pneumatical
Material Electrode holder, rinse chamber and raised face: PEEK, PVDF, conductive PVDF, Alloy C22, stainless steel 1.4571
Seals: EPDM, FPM (Viton) or FFKM (Kalrez®)
Dimension Immersion depth: 146 or 280 mm (5.75 or 7.87 inch)
Process temperature 0 to 140 °C (32 to 284 °F)
Process pressure 0 to max. 4 bar (0 to max. 58 psi) overpressure for manual actuation
0 to 10 bar (0 to 145 psi) overpressure for pneumatic actuation
Connection Process connections: Flange DN 50, DN 80, ANSI 2", JIS IS10K50A, internal thread G1¼

ORP/Redox Specification

Measuring principle Sensor ORP / Redox
Application Chemical industry, biodiesel plants, power plants, plant design, tanks, process vats or pipes
Installation Retractable holder
Characteristic For tanks and process vats and pipelines or pipes (min. DN80)
The robust retractable assembly permits replacement of the electrode while the tank is full or under process conditions with pressures of up to 6 bar
Design Manual or pneumatical
Material Electrode holder, rinse chamber and raised face: PEEK, PVDF, conductive PVDF, Alloy C22, stainless steel 1.4571
Seals: EPDM, FPM (Viton) or FFKM (Kalrez®)
Dimension Immersion depth: 146 or 280 mm (5.75 or 7.87 inch)
Process temperature 0 to 140 °C (32 to 284 °F)
Process pressure 0 to max. 4 bar (0 to max. 58 psi) overpressure for manual actuation
0 to 10 bar (0 to 145 psi) overpressure for pneumatic actuation
Connection Process connections: Flange DN 50, DN 80, ANSI 2", JIS IS10K50A, internal thread G1¼