null
Endress+Hauser

Microwave barrier transceiver Soliwave FDR57

(No reviews yet) Write a Review
SKU:
Soliwave FDR57 Series
Weight:
0.00 Grams
Call us: +971 4 259 5133

Description

Application

The Soliwave FDR57 microwave barrier transceiver operates using a non-contact method to detect point levels and monitor bulk flow (flow/no flow, trend). It is well-suited for detecting and counting objects, analyzing deposits, and overseeing filling processes and material transfer points. The device can be easily installed in various locations, such as containers, pipelines, hoppers, filling stations, shafts, filters, or free fall chutes. Measurement through non-metallic container walls is possible from the exterior.

Key features include:

  • Non-contact, wear-free limit detection (min/max) and flow monitoring for bulk solids.
  • Detection, counting, and positioning of objects.
  • Detection and analysis of deposits and contamination in filters.
  • Monitoring of filling processes and material transfer points.
  • Suitable for high-temperature applications up to 450°C (842°F).
  • Supports high-pressure applications up to 20 bar (290 psi).
  • Certified for international explosion protection standards.

 


Benefits

  • Easy installation using R 1½, 1½ NPT thread, or G 1½ connections (with lock nut).
  • Durable mechanical design ensures long-term cost savings: no wear and tear, optional ceramic sensor diaphragm for process-wetted applications, maintenance-free with extended service life.
  • Mechanically compatible with FQR50/FDR50 and FQR56/FDR56 models, enabling reuse of existing process connections and accessories like adapter flanges, installation brackets, and sight glasses.
  • Enhanced safety in point level monitoring with optional integrated bulk flow monitoring.
  • Reliable performance with minimal dependence on process conditions.
  • Effective even in challenging applications where other measurement techniques may not succeed.
  • Simple and efficient operation using the Nivotester FTR525 with a graphical display, reducing both setup time and costs.

 

SPECIFICATIONS

Point Level / Solids Specifications

Measuring principle

 

Microwave barrier

 

Characteristic / Application

 

Transceiver

Non-contact point level detection and flow monitoring

Detecting, counting and positioning of objects

Monitoring of material transfer points

Detection and analysis of deposits and contamination

Installation:

Non-contact installation (tranmission window) or front-flush installation (contact)

 

Specialities

With optional integrated bulk flow monitoring

Parallel mode with up to 5 channels

Detection range limit: max. 100 m

Detection range flow: max. 10 m, depending on bulk solids

 

Supply / Communication

 

Via process transmitter with control unit Nivotester FTR525

 

Ambient temperature

 

-40 °C...+70 °C

(-40 °F...+158 °F)

 

Process temperature

 

Non-contact installation: any

Within installation:

-40°C ... +70°C

(-40°F ... +158°F)

With high temperature adapter:

up to +450°C (+842°F)

 

Process pressure / max. overpressure limit

 

Non-contact installation: any

Within installation:

0.5 bar ... 6.8 bar

(7.2 psi ... 99 psi) abs.

With high pressure adapter:

up to +21 bar (+305 psi) abs.

 

Min. density of medium

 

Solid weight: > 10 g/l

 

Main wetted parts

 

Non-contact installation:

no wetted parts

Within installation:

316Ti, PTFE or Ceramic

 

Process connection

 

Threads:

1-1/2" R, 1-1/2" G, 1-1/2" NPT

 

Communication

 

Via process transmitter with control unit Nivotester FTR525

 

Certificates / Approvals

 

ATEX, CSA C/US, IEC Ex

 

Design approvals

 

EN10204-3.1

 

Options

 

Sight glass

High temperature adapter

High pressure adapter

Installation bracket

FAR50, FAR51, FAR52, FAR53, FAR54, FAR55

 

Components

 

Transmitter: FQR57

Process transmitter: FTR525

 

Application limits

 

Solid weight: < 10 g/l

 

 

 

Documents

You may want to read this product's catalog. If so, please click to view the Endress+Hauser Soliwave FDR57 Series datasheet.