Application
The Soliwave FQR16 is a highly compact transceiver designed for non-contact point level detection in bulk solids, liquids, and for counting piece goods or detecting objects. Paired with the FDR16, it utilizes a microwave barrier system that enables non-contact measurement, making it ideal for installations in hard-to-reach or tight spaces due to its ultra-compact structure. For non-metallic containers, the system can even perform measurements externally.
The Soliwave FDR16 and FQR16 effectively detect minimum and maximum point levels in a wide range of bulk solids—from powdery to lumpy materials—and liquids, offering protection against overflow or dry running. Additionally, it supports piece goods counting and object detection across various industries, including primary materials, energy, and food processing.
Benefits
- Non-contact measurement method – detection largely unaffected by process conditions
- Enhanced safety – continuous self-diagnosis and comprehensive self-testing
- First microwave barrier with IP69 protection rating
- Compliant with EU regulation 1935/2004
- Easy and cost-efficient commissioning process
- Reliable detection – non-contact method ensures wear-free, maintenance-free operation
- Durable construction – robust stainless-steel housing
SPECIFICATIONS
Point Level / Solids Specifications
Measuring principle
|
Microwave barrier
|
Characteristic / Application
|
Microwave barrier Non-contact point level detection (min/max, e.g. full and empty detection for overflow and dry run protection) for all types of bulk solids (from powdery to lumpy) and liquids, also in potentially explosive atmospheres (dust Ex). Detection, counting, and positioning of objects Object detection on conveyor belts
|
Specialities |
Detection range: max. 20 m
|
Supply / Communication
|
18 V ... 30 V DC, Plug M12
|
Ambient temperature
|
-20°C ... +60°C (-4°F ... +140°F)
|
Process temperature
|
Non-contact installation: any Within installation: -20°C ... +60°C (-4°F ...+140°F) With high temperature adapter: up to +450°C (+842°F)
|
Process pressure / max. overpressure limit
|
Non-contact installation: any Within installation: 0.5 bar ... 6.8 bar (7.2 psi ... 99 psi) abs. With high pressure adapter: up to +21 bar (+305 psi) abs.
|
Min. density of medium
|
Solid weight: > 10 g/l
|
Main wetted parts
|
Non-contact installation: no wetted parts Contact installation: 316L, PTFE
|
Process connection
|
ISO228-1: G1", G1-1/2" ASME: NPT1-1/2"
|
Process connection hygienic
|
Non-contact installation |
Communication
|
3-wire-DC-PNP, 2 DC-PNP-outputs
|
Certificates / Approvals
|
ATEX, IEC Ex
|
Design approvals
|
EN10204-3.1
|
Hygienic approvals
|
EG1935/2004
|
Options
|
Mounting bracket Counternut Welding sleeve Connection cable Connecting cable High-pressure adapter High-temperature adapter Extension for HT adapter Mounting flange Sight glass fitting FAR50, FAR51, FAR52, FAR54
|
Components |
FDR16
|
Application limits
|
Solid weight: < 10 g/l
|
Documents