Application

The durable Promass E is well-known for its reliable performance in accurately measuring liquids and gases across a variety of standard applications. Its ultra-compact transmitter ensures full functionality in the smallest space, enabling easy integration into systems, making it a top choice for skid builders, equipment manufacturers, and system integrators. Heartbeat Technology ensures measurement precision and facilitates verification in line with compliance standards.

  • The measurement principle functions independently of the fluid's physical properties such as viscosity or density.
  • Accurate measurement of liquids and gases for a broad range of standard applications.

Device Properties:

  • Compact dual-tube sensor
  • Medium temperature capability up to +150 °C (+302 °F)
  • Process pressure: up to 100 bar (1450 psi)
  • Sturdy, ultra-compact transmitter housing
  • High ingress protection rating: IP69
  • Optional local display

Benefits

  • Cost-effective: A versatile solution, offering an alternative to traditional volumetric flowmeters.
  • Fewer measuring points: Multivariable measurements including flow, density, and temperature.
  • Space-efficient installation: No need for in-/outlet runs.
  • Compact transmitter: Full functionality within a minimal footprint.
  • Time-saving local operation: No additional software or hardware required, thanks to the integrated web server.
  • Integrated verification: Ensures reliability with Heartbeat Technology.

SPECIFICATIONS

Liquids Specifications

Measuring principle

 


 

Coriolis

 

 

 

Product headline

 

 

Flowmeter with minimized total cost of ownership and an ultra-compact transmitter.

Accurate measurement of liquids and gases for a wide range of standard applications.

 

 

Sensor features

 

 

Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.

Compact dual-tube sensor. Medium temperature up to +150 °C (+302 °F). Process pressure up to 100 bar (1450 psi).

 

 

Transmitter features

 

 

Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology.

Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available.

 

 

 

Nominal diameter range

 

 

DN 8 to 80 (⅜ to 3")

 

Wetted materials

 

Measuring tube: 1.4539 (904L)

Connection: 1.4404 (316/316L)

 

Measured variables

 

Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

 

Max. measurement error

 

Mass flow (liquid): ±0.15 % (standard), ±0.10 % (option)

Volume flow (liquid): ±0.15 %

Mass flow (gas): ±0.50 %

Density (liquid): ±0.0005 g/cm³

 

 

Measuring range

 

 

0 to 180 000 kg/h (0 to 6600 lb/min)

 

Max. process pressure

 

PN 100, Class 600, 63K

 

Medium temperature range

 

–40 to +150 °C (–40 to +302°F)

 

Ambient temperature range

 

 

Standard: –40 to +60 °C (–40 to +140 °F)

Option: –50 to +60 °C (–58 to +140°F)

 

 

Sensor housing material

 

 

1.4301 (304), corrosion resistant

 

Transmitter housing material

 

Compact: AlSi10Mg, coated

Compact/ultra‐compact: 1.4301 (304)

 

Degree of protection

 

Standard: IP66/67, type 4X enclosure

Option: IP69

 

Display/Operation

 

4‐line backlit display available (no local operation)

Configuration via web browser and operating tools possible

 

Outputs

 

 

4‐20 mA HART (active)

Pulse/frequency/switch output (passive)

 

 

Inputs

 

 

None

 

 

Digital communication

 

HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET

Power supply

 

DC 20 to 30 V

 

Hazardous area approvals

 

ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC

 

Product safety

 

 

CE, C-Tick, EAC marking

 

 

Metrological approvals and certificates

 

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)

Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

 

Hygienic approvals and certificates

 

 

3-A, EHEDG, cGMP

 

 

Material certificates

 

 

3.1 material

 

 

Marine approvals and certificates

 

 

 

LR approval, DNV approval, ABS approval, BV approval, CCS approval

 

 

Pressure approvals and certificates

 

PED, CRN

 

Gas Specifications

Measuring principle

 

 

Coriolis

 

 

Product headline

 

 

Flowmeter with minimized total cost of ownership and an ultra-compact transmitter.

Accurate measurement of liquids and gases for a wide range of standard applications.

 

Sensor features

 

 

Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.

Compact dual-tube sensor. Medium temperature up to +150 °C (+302 °F). Process pressure up to 100 bar (1450 psi).

 

Transmitter features

 

 

Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology.

Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available.

 

 Nominal diameter range  

DN 8 to 80 (⅜ to 3")

 

 

Wetted materials

 

 

Measuring tube: 1.4539 (904L)

Connection: 1.4404 (316/316L)

 

 

Measured variables

 

 

Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

 

 

Max. measurement error

 

 

Mass flow (liquid): ±0.15 % (standard), ±0.10 % (option)

Volume flow (liquid): ±0.15 %

Mass flow (gas): ±0.50 %

Density (liquid): ±0.0005 g/cm³

 

Measuring range

 

 

0 to 180 000 kg/h (0 to 6600 lb/min)

 

Max. process pressure

 

PN 100, Class 600, 63K

Medium temperature range

 

 

–40 to +150 °C (–40 to +302°F)

 

 

Ambient temperature range

 

 

Standard: –40 to +60 °C (–40 to +140 °F)

Option: –50 to +60 °C (–58 to +140°F)

 

 

Sensor housing material

 

 

1.4301 (304), corrosion resistant

 

 

Transmitter housing material

 

 

Compact: AlSi10Mg, coated

Compact/ultra‐compact: 1.4301 (304)

 

Degree of protection

Standard: IP66/67, type 4X enclosure

Option: IP69

 

 

Display/Operation

 

 

4‐line backlit display available (no local operation)

Configuration via web browser and operating tools possible

Outputs

 

4‐20 mA HART (active)

Pulse/frequency/switch output (passive)

Inputs

 

None

 

Digital communication

 

HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET

 

Power supply

 

 

DC 20 to 30 V

 

 

Hazardous area approvals

 

 

ATEX, IECEx, cCSAus, INMETRO, NEPSI

 

 

Product safety

 

 

CE, C-Tick, EAC marking

 

 

Metrological approvals and certificates

 

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)

Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

 

Marine approvals and certificates

 

LR approval, DNV approval, ABS approval, BV approval, CCS approval

 

 

Material certificates

 

 

3.1 material

 

 

Hygienic approvals and certificates

 

 

3-A, EHEDG, cGMP

 

Pressure approvals and certificates

 

PED, CRN

 

 

Documents

You may want to read this product's catalog. If so, please click to view the Proline Promass E 100 Series datasheet.
View AllClose