Endress+Hauser
Mid-range Coriolis Flowmeter Proline Promass E 100
- SKU:
- Proline Promass E 100 Series
- MPN:
- Proline Promass E 100
- Weight:
- 0.00 Grams
Description
Application
The durable Promass E is well-known for its reliable performance in accurately measuring liquids and gases across a variety of standard applications. Its ultra-compact transmitter ensures full functionality in the smallest space, enabling easy integration into systems, making it a top choice for skid builders, equipment manufacturers, and system integrators. Heartbeat Technology ensures measurement precision and facilitates verification in line with compliance standards.
- The measurement principle functions independently of the fluid's physical properties such as viscosity or density.
- Accurate measurement of liquids and gases for a broad range of standard applications.
Device Properties:
- Compact dual-tube sensor
- Medium temperature capability up to +150 °C (+302 °F)
- Process pressure: up to 100 bar (1450 psi)
- Sturdy, ultra-compact transmitter housing
- High ingress protection rating: IP69
- Optional local display
Benefits
- Cost-effective: A versatile solution, offering an alternative to traditional volumetric flowmeters.
- Fewer measuring points: Multivariable measurements including flow, density, and temperature.
- Space-efficient installation: No need for in-/outlet runs.
- Compact transmitter: Full functionality within a minimal footprint.
- Time-saving local operation: No additional software or hardware required, thanks to the integrated web server.
- Integrated verification: Ensures reliability with Heartbeat Technology.
SPECIFICATIONS
Liquids Specifications
Measuring principle
|
Coriolis
|
Product headline
|
Flowmeter with minimized total cost of ownership and an ultra-compact transmitter. Accurate measurement of liquids and gases for a wide range of standard applications.
|
Sensor features
|
Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Compact dual-tube sensor. Medium temperature up to +150 °C (+302 °F). Process pressure up to 100 bar (1450 psi).
|
Transmitter features
|
Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology. Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available.
|
Nominal diameter range
|
DN 8 to 80 (⅜ to 3")
|
Wetted materials
|
Measuring tube: 1.4539 (904L) Connection: 1.4404 (316/316L)
|
Measured variables
|
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
|
Max. measurement error
|
Mass flow (liquid): ±0.15 % (standard), ±0.10 % (option) Volume flow (liquid): ±0.15 % Mass flow (gas): ±0.50 % Density (liquid): ±0.0005 g/cm³
|
Measuring range
|
0 to 180 000 kg/h (0 to 6600 lb/min)
|
Max. process pressure
|
PN 100, Class 600, 63K
|
Medium temperature range
|
–40 to +150 °C (–40 to +302°F)
|
Ambient temperature range
|
Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140°F)
|
Sensor housing material
|
1.4301 (304), corrosion resistant
|
Transmitter housing material
|
Compact: AlSi10Mg, coated Compact/ultra‐compact: 1.4301 (304)
|
Degree of protection
|
Standard: IP66/67, type 4X enclosure Option: IP69
|
Display/Operation
|
4‐line backlit display available (no local operation) Configuration via web browser and operating tools possible |
Outputs
|
4‐20 mA HART (active) Pulse/frequency/switch output (passive)
|
Inputs
|
None
|
Digital communication
|
HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET |
Power supply
|
DC 20 to 30 V
|
Hazardous area approvals
|
ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC
|
Product safety
|
CE, C-Tick, EAC marking
|
Metrological approvals and certificates
|
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
|
Hygienic approvals and certificates
|
3-A, EHEDG, cGMP
|
Material certificates
|
3.1 material
|
Marine approvals and certificates
|
LR approval, DNV approval, ABS approval, BV approval, CCS approval
|
Pressure approvals and certificates
|
PED, CRN
|
Gas Specifications
Measuring principle
|
Coriolis
|
Product headline
|
Flowmeter with minimized total cost of ownership and an ultra-compact transmitter. Accurate measurement of liquids and gases for a wide range of standard applications. |
Sensor features
|
Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Compact dual-tube sensor. Medium temperature up to +150 °C (+302 °F). Process pressure up to 100 bar (1450 psi). |
Transmitter features
|
Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology. Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available.
|
Nominal diameter range |
DN 8 to 80 (⅜ to 3")
|
Wetted materials
|
Measuring tube: 1.4539 (904L) Connection: 1.4404 (316/316L)
|
Measured variables
|
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
|
Max. measurement error
|
Mass flow (liquid): ±0.15 % (standard), ±0.10 % (option) Volume flow (liquid): ±0.15 % Mass flow (gas): ±0.50 % Density (liquid): ±0.0005 g/cm³ |
Measuring range
|
0 to 180 000 kg/h (0 to 6600 lb/min)
|
Max. process pressure
|
PN 100, Class 600, 63K |
Medium temperature range
|
–40 to +150 °C (–40 to +302°F)
|
Ambient temperature range
|
Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140°F)
|
Sensor housing material
|
1.4301 (304), corrosion resistant
|
Transmitter housing material
|
Compact: AlSi10Mg, coated Compact/ultra‐compact: 1.4301 (304)
|
Degree of protection |
Standard: IP66/67, type 4X enclosure Option: IP69
|
Display/Operation
|
4‐line backlit display available (no local operation) Configuration via web browser and operating tools possible |
Outputs
|
4‐20 mA HART (active) Pulse/frequency/switch output (passive) |
Inputs
|
None
|
Digital communication
|
HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET
|
Power supply
|
DC 20 to 30 V
|
Hazardous area approvals
|
ATEX, IECEx, cCSAus, INMETRO, NEPSI
|
Product safety
|
CE, C-Tick, EAC marking
|
Metrological approvals and certificates
|
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
|
Marine approvals and certificates
|
LR approval, DNV approval, ABS approval, BV approval, CCS approval
|
Material certificates
|
3.1 material
|
Hygienic approvals and certificates
|
3-A, EHEDG, cGMP
|
Pressure approvals and certificates
|
PED, CRN
|
Documents