null
Endress+Hauser

Multivariable Measuring Coriolis Flowmeter CNGmass D8CB

(No reviews yet) Write a Review
SKU:
CNGmass D8CB Series
MPN:
CNGmass D8CB
Weight:
0.00 Grams
+971 4 259 5133

Description

Application

The demand for natural gas continues to rise! Compressed natural gas (CNG) has been a well-established alternative fuel for vehicles for some time, known for being the cleanest option for combustion engines. The new CNGmass is specifically engineered for use in dispensers. This Coriolis flowmeter ensures highly accurate mass flow measurements, regardless of pressure or temperature variations. Its measurement principle functions independently of physical fluid properties, such as viscosity or density, ensuring precise readings. Ideal for accurate measurement of compressed natural gas (CNG) in high-pressure refueling environments. Device Properties:

  • Flow rates up to 150 kg/min (330 lb/min)
  • Process pressure up to 350 bar (5080 psi)
  • Includes a rupture disc for added safety
  • Durable and compact transmitter housing
  • Modbus RS485 connectivity
  • Tailored to meet specific application requirements

Benefits

  • Exceptional operational safety – Reliable performance even under challenging process conditions.
  • Reduced measuring points – Offers multivariable measurement capabilities (flow, density, temperature) in a single device.
  • Compact installation – Requires no in/outlet runs, saving space.
  • Space-efficient transmitter – Delivers full functionality in a minimal footprint.
  • Quick start-up – Comes pre-configured for fast commissioning.
  • Easy maintenance – Automatic data recovery during servicing

Documents

You may want to read this product's catalog. If so, please click to view the CNGmass D8CB Series datasheet.

SPECIFICATIONS

Liquids Specifications

Measuring principle Coriolis
Product headline The refueling application flowmeter with seamless system integration. Accurate measurement of compressed natural gas (CNG) in high pressure refueling applications.
Sensor features Excellent operational safety – reliable under extreme process conditions. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Flow rates up to 150 kg/min (330 lb/min). Process pressure up to 350 bar (5080 psi).
Transmitter features Space‐saving transmitter – full functionality on the smallest footprint. Fast commissioning – pre‐configured devices. Automatic recovery of data for servicing. Robust, compact transmitter housing. Modbus RS485.
Nominal diameter range DN 8 to 25 (⅜ to 1")
Wetted materials Measuring tube: 1.4435 (316L)
Connection: 1.4404 (316/316L)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. measurement error Mass flow: ±0.5 % of batch
Measuring range 0 to 150 kg/min (0 to 330 lb/min)
Max. process pressure 350 bar (5080 psi)
Medium temperature range –50 to +125 °C (–58 to +257 °F)
Ambient temperature range –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material AlSi10Mg, coated
Degree of protection IP66/67, type 4X enclosure
Display/Operation No local operation
Configuration via operating tools possible
Outputs None
Inputs None
Digital communication Modbus RS485
Power supply DC 20 to 30 V
Hazardous area approvals ATEX, IECEx, cCSAus, NEPSI, INMETRO
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Pressure approvals and certificates CRN
Material certificates 3.1 material

Gas Specifications

Measuring principle Coriolis
Product headline The refueling application flowmeter with seamless system integration. Accurate measurement of compressed natural gas (CNG) in high pressure refueling applications.
Sensor features Excellent operational safety – reliable under extreme process conditions. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Flow rates up to 150 kg/min (330 lb/min). Process pressure up to 350 bar (5080 psi).
Transmitter features Space‐saving transmitter – full functionality on the smallest footprint. Fast commissioning – pre‐configured devices. Automatic recovery of data for servicing. Robust, compact transmitter housing. Modbus RS485.
Nominal diameter range DN 8 to 25 (⅜ to 1")
Wetted materials Measuring tube: 1.4435 (316L)
Connection: 1.4404 (316/316L)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. measurement error Mass flow: ±0.5 % of batch
Measuring range 0 to 150 kg/min (0 to 330 lb/min)
Max. process pressure 350 bar (5080 psi)
Medium temperature range –50 to +125 °C (–58 to +257 °F)
Ambient temperature range –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material AlSi10Mg, coated
Degree of protection IP66/67, type 4X enclosure
Display/Operation No local operation
Configuration via operating tools possible
Outputs None
Inputs None
Digital communication Modbus RS485
Power supply DC 20 to 30 V
Hazardous area approvals ATEX, IECEx, cCSAus, NEPSI, INMETRO
Other approvals and certificates 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
CRN
View AllClose