Description
Application
The Promass I's straight single-tube design allows for in-line viscosity measurement, along with mass flow, density, and temperature measurement. With its advanced remote transmitter, the Promass I 500 ensures maximum installation flexibility and operational safety in challenging environments. The inclusion of Heartbeat Technology guarantees reliable measurement and verification compliance. The measuring principle functions independently of fluid properties such as viscosity or density, making it ideal for both liquid and gas measurement in applications where low pressure loss and gentle fluid handling are required.
Device Properties
- Straight, easy-to-clean single-tube system
- TMB technology
- Measuring tube constructed from Titanium
- Remote version with up to 4 I/Os
- Backlit display with touch control and WLAN access
- Standard cable between sensor and transmitter
Benefits
- Energy efficiency: The full-bore design ensures minimal pressure loss.
- Multivariable measurement: Fewer process measuring points required, as it measures flow, density, and temperature simultaneously.
- Compact installation: No need for in-/outlet runs, saving space.
- Enhanced diagnostics: Full access to process and diagnostic data through various I/O configurations and Ethernet.
- Simplified configuration: Freely configurable I/O functionality reduces complexity.
- Built-in verification: Heartbeat Technology provides integrated system verification.
Documents
You may want to read this product's catalog. If so, please click to view the Proline Promass I 500 Series datasheet.SPECIFICATIONS
Liquids Specifications
Measuring principle | Coriolis |
Product headline | Combines in-line viscosity and flow measurement with a transmitter remote version with up to 4 I/Os. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment. |
Sensor features | Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium. |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Nominal diameter range | DN 8 to 80 (⅜ to 3") |
Wetted materials | Measuring tube: Titanium grade 9; Connection: Titanium grade 2 |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity |
Max. measurement error | Mass flow (liquid): ±0.10 %, Volume flow (liquid): ±0.10 %, Mass flow (gas): ±0.50 %, Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 180,000 kg/h (0 to 6600 lb/min) |
Max. process pressure | PN 100, Class 600, 63K |
Medium temperature range | –50 to +150 °C (–58 to +302 °F) |
Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F); Option: –50 to +60 °C (–58 to +140 °F) |
Sensor housing material | 1.4301 (304), corrosion resistant |
Sensor connection housing (standard) | AlSi10Mg, coated |
Sensor connection housing (option) | 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L |
Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonate |
Degree of protection | Sensor remote version (standard): IP66/67, type 4X enclosure, Option: IP69. Transmitter remote version: IP66/67, Type 4X enclosure |
Display/Operation | 4-line backlit display with touch control (operation from outside), Configuration via local display and operating tools possible |
Outputs | 4 outputs: 4-20 mA HART (active/passive), 4-20 mA WirelessHART, 4-20 mA (active/passive), Pulse/frequency/switch output (active/passive), Double pulse output (active/passive), Relay output |
Inputs | Status input, 4-20 mA input |
Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
Power supply | DC 24 V, AC 100 to 230 V, AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
Product safety | CE, C-Tick, EAC marking |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
Pressure approvals and certificates | PED, CRN |
Material certificates | 3.1 material |
Hygienic approvals and certificates | 3-A, EHEDG, cGMP |
Gas Specifications
Measuring principle | Coriolis |
Product headline | Combines in-line viscosity and flow measurement with a transmitter remote version with up to 4 I/Os. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment. |
Sensor features | Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium. |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Nominal diameter range | DN 8 to 80 (⅜ to 3") |
Wetted materials | Measuring tube: Titanium grade 9; Connection: Titanium grade 2 |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity |
Max. measurement error | Mass flow (liquid): ±0.10 %, Volume flow (liquid): ±0.10 %, Mass flow (gas): ±0.50 %, Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 180,000 kg/h (0 to 6600 lb/min) |
Max. process pressure | PN 100, Class 600, 63K |
Medium temperature range | –50 to +150 °C (–58 to +302 °F) |
Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F); Option: –50 to +60 °C (–58 to +140 °F) |
Sensor housing material | 1.4301 (304), corrosion resistant |
Sensor connection housing (standard) | AlSi10Mg, coated |
Sensor connection housing (option) | 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L |
Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonate |
Degree of protection | Sensor remote version (standard): IP66/67, type 4X enclosure, Option: IP69. Transmitter remote version: IP66/67, Type 4X enclosure |
Display/Operation | 4-line backlit display with touch control (operation from outside), Configuration via local display and operating tools possible |
Outputs | 4 outputs: 4-20 mA HART (active/passive), 4-20 mA WirelessHART, 4-20 mA (active/passive), Pulse/frequency/switch output (active/passive), Double pulse output (active/passive), Relay output |
Inputs | Status input, 4-20 mA input |
Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
Power supply | DC 24 V, AC 100 to 230 V, AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
Product safety | CE, C-Tick, EAC marking |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
Pressure approvals and certificates | PED, CRN |
Material certificates | 3.1 material |
Hygienic approvals and certificates | 3-A, EHEDG, cGMP |
Viscosity Specifications
Measuring principle | Coriolis |
Product headline | Combines in-line viscosity and flow measurement with a transmitter remote version with up to 4 I/Os. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment. |
Sensor features | Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium. |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Nominal diameter range | DN 8 to 80 (⅜ to 3") |
Wetted materials | Measuring tube: Titanium grade 9; Connection: Titanium grade 2 |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity |
Max. measurement error | Mass flow (liquid): ±0.10 %, Volume flow (liquid): ±0.10 %, Mass flow (gas): ±0.50 %, Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 180,000 kg/h (0 to 6600 lb/min) |
Max. process pressure | PN 100, Class 600, 63K |
Medium temperature range | –50 to +150 °C (–58 to +302 °F) |
Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F); Option: –50 to +60 °C (–58 to +140 °F) |
Sensor housing material | 1.4301 (304), corrosion resistant |
Sensor connection housing (standard) | AlSi10Mg, coated |
Sensor connection housing (option) | 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L |
Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonate |
Degree of protection | Sensor remote version (standard): IP66/67, type 4X enclosure, Option: IP69. Transmitter remote version: IP66/67, Type 4X enclosure |
Display/Operation | 4-line backlit display with touch control (operation from outside), Configuration via local display and operating tools possible |
Outputs | 4 outputs: 4-20 mA HART (active/passive), 4-20 mA WirelessHART, 4-20 mA (active/passive), Pulse/frequency/switch output (active/passive), Double pulse output (active/passive), Relay output |
Inputs | Status input, 4-20 mA input |
Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
Power supply | DC 24 V, AC 100 to 230 V, AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
Product safety | CE, C-Tick, EAC marking |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
Pressure approvals and certificates | PED, CRN |
Material certificates | 3.1 material |
Hygienic approvals and certificates | 3-A, EHEDG, cGMP |
Density Specifications
Measuring principle | Coriolis |
Product headline | Combines in-line viscosity and flow measurement with a transmitter remote version with up to 4 I/Os. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment. |
Sensor features | Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium. |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Density/Concentration Specifications
Measuring principle | Coriolis |
Product headline | Combines in-line viscosity and flow measurement with a transmitter remote version with up to 4 I/Os. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment. |
Sensor features | Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium. |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Nominal diameter range | DN 8 to 80 (⅜ to 3") |
Wetted materials | Measuring tube: Titanium grade 9 Connection: Titanium grade 2 |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity |
Max. measurement error | Mass flow (liquid): ±0.10 % Volume flow (liquid): ±0.10 % Mass flow (gas): ±0.50 % Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 180,000 kg/h (0 to 6600 lb/min) |
Max. process pressure | PN 100, Class 600, 63K |
Medium temperature range | –50 to +150 °C (–58 to +302 °F) |
Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
Sensor housing material | 1.4301 (304), corrosion resistant Sensor connection housing (standard): AlSi10Mg, coated Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L |
Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonate |
Degree of protection | Sensor remote version (standard): IP66/67, type 4X enclosure Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure |
Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
Outputs | 4 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
Inputs | Status input 4-20 mA input |
Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
Product safety | CE, C-tick, EAC marking |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
Pressure approvals and certificates | PED, CRN |
Material certificates | 3.1 material |
Hygienic approvals and certificates | 3-A, EHEDG, cGMP |