Endress+Hauser
Premium Accuracy Coriolis Flowmeter Proline Promass F 500
- SKU:
- Proline Promass F 500 Series
- MPN:
- Proline Promass F 500
- Weight:
- 0.00 Grams
Description
Application
The Promass F sensor is known for its exceptional accuracy and reliability, making it suitable for a wide range of applications, even in challenging and fluctuating environments. Its innovative remote transmitter, the Promass F 500, enhances installation flexibility and ensures operational safety in demanding settings. With Heartbeat Technology, it provides reliable measurement and extends recalibration intervals.
- The measuring principle functions independently of fluid properties such as viscosity and density.
- Delivers the highest measurement accuracy for both liquids and gases, even under variable and demanding process conditions.
Device Properties:
- Mass flow measurement accuracy: ±0.05% (PremiumCal)
- Medium temperature range: -196 to 350 °C (-320 to 662 °F)
- Nominal diameter: DN 8 to 250 (³⁄₈ to 10")
- Remote version with up to 4 I/Os
- Backlit display with touch controls and WLAN access
- Standard cable between sensor and transmitter
Benefits
- Superior process safety: Resistant to fluctuating and harsh environments.
- Multi-parameter measurement: Combines flow, density, and temperature, reducing the need for multiple measuring points.
- Compact installation: No need for inlet or outlet runs, saving space.
- Comprehensive access: Full access to process and diagnostic data through numerous, customizable I/Os and Ethernet.
- Simplified configuration: Freely configurable I/O functionality, reducing complexity.
- Built-in verification: Integrated Heartbeat Technology for continuous monitoring and verification.
Documents
You may want to read this product's catalog. If so, please click to view the Proline Promass F 500 Series datasheet.SPECIFICATIONS
Liquids Specifications
Measuring principle | Coriolis |
Product headline | Flowmeter with premium accuracy and robustness, as remote version with up to 4 I/Os. Highest measurement performance for liquids and gases under varying, demanding process conditions. |
Sensor features | Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Mass flow: measurement error ±0.05 % (PremiumCal). Medium temperature: –196 to 350 °C (–320 to 662 °F). Nominal diameter: DN 8 to 250 (³⁄₈ to 10"). |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Nominal diameter range | DN 8 to 250 (⅜ to 10") |
Wetted materials | Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022). Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022); 1.4301 (F304) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.10 % (standard), 0.05 % (option). Volume flow (liquid): ±0.10 %. Mass flow (gas): ±0.25 %. Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 2 200 000 kg/h (0 to 80 840 lb/min) |
Max. process pressure | PN 100, Class 600, 63K |
Medium temperature range | Standard: –50 to +150 °C (–58…+302 °F). Option: –50 to +240 °C (–58…+464 °F). High temperature option: –50 to +350 °C (–58…+662 °F). Option: –196 to +150 °C (–320 to +302 °F) |
Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F). Option: –60 to +60 °C (–76 to +140 °F) |
Sensor housing material | Standard: 1.4301 (304), corrosion resistant. Option: 1.4404 (316L). Sensor connection housing (standard): AlSi10Mg, coated. Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L |
Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonate |
Degree of protection | Sensor remote version (standard): IP66/67, type 4X enclosure. Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure |
Display/Operation | 4-line backlit display with touch control (operation from outside). Configuration via local display and operating tools possible |
Outputs | 4 outputs: 4-20 mA HART (active/passive), 4-20 mA WirelessHART, 4-20 mA (active/passive), Pulse/frequency/switch output (active/passive), Double pulse output (active/passive), Relay output |
Inputs | Status input, 4-20 mA input |
Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
Power supply | DC 24 V, AC 100 to 230 V, AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
Product safety | CE, C-tick, EAC marking |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025). Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation). MI-005 (Liquids other than water, Hydrocarbons, LPG, cryogenic liquids). NTEP (Liquids other than water, LPG, cryogenic liquids). MC (Liquids other than water, gases, cryogenic liquids). MI-002, PTB |
Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval, CCS approval |
Pressure approvals and certificates | PED, CRN, AD 2000 |
Material certificates | 3.1 material. NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK |
Hygienic approvals and certificates | 3-A, EHEDG, cGMP |
Gas Specifications
Measuring principle | Coriolis |
Product headline | Flowmeter with premium accuracy and robustness, as remote version with up to 4 I/Os. Highest measurement performance for liquids and gases under varying, demanding process conditions. |
Sensor features | Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Mass flow: measurement error ±0.05 % (PremiumCal). Medium temperature: –196 to 350 °C (–320 to 662 °F). Nominal diameter: DN 8 to 250 (³⁄₈ to 10"). |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Nominal diameter range | DN 8 to 250 (⅜ to 10") |
Wetted materials | Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022). Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022); 1.4301 (F304) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.10 % (standard), 0.05 % (option). Volume flow (liquid): ±0.10 %. Mass flow (gas): ±0.25 %. Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 2 200 000 kg/h (0 to 80 840 lb/min) |
Max. process pressure | PN 100, Class 600, 63K |
Medium temperature range | Standard: –50 to +150 °C (–58 to +302 °F). Option: –50 to +240 °C (–58 to +464 °F). High temperature option: –50 to +350 °C (–58 to +662 °F). Option: –196 to +150 °C (–320 to +302 °F) |
Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F). Option: –60 to +60 °C (–76 to +140 °F) |
Sensor housing material | Standard: 1.4301 (304), corrosion resistant. Option: 1.4404 (316L). Sensor connection housing (standard): AlSi10Mg, coated. Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L |
Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonate |
Degree of protection | Sensor remote version (standard): IP66/67, type 4X enclosure. Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure. External WLAN antenna: IP67 |
Display/Operation | 4-line backlit display with touch control (operation from outside). Configuration via local display and operating tools possible |
Outputs | 4 outputs: 4-20 mA HART (active/passive), 4-20 mA WirelessHART, 4-20 mA (active/passive), Pulse/frequency/switch output (active/passive), Double pulse output (active/passive), Relay output |
Inputs | Status input, 4-20 mA input |
Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
Power supply | DC 24 V, AC 100 to 230 V, AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
Product safety | CE, C-tick, EAC marking |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025). Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation). MI-005 (Liquids other than water, Hydrocarbons, LPG, cryogenic liquids). NTEP (Liquids other than water, LPG, cryogenic liquids). MC (Liquids other than water, gases, cryogenic liquids). MI-002, PTB |
Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval, CCS approval |
Pressure approvals and certificates | PED, CRN, AD 2000 |
Material certificates | 3.1 material. NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK |
Hygienic approvals and certificates | 3-A, EHEDG, cGMP |
Steam Specifications
Measuring principle | Coriolis |
Product headline | Flowmeter with premium accuracy and robustness, as remote version with up to 4 I/Os. Highest measurement performance for liquids and gases under varying, demanding process conditions. |
Sensor features | Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Mass flow: measurement error ±0.05 % (PremiumCal). Medium temperature: –196 to 350 °C (–320 to 662 °F). Nominal diameter: DN 8 to 250 (³⁄₈ to 10"). |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Nominal diameter range | DN 8 to 250 (⅜ to 10") |
Wetted materials | Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022). Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022); 1.4301 (F304) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.10 % (standard), 0.05 % (option). Volume flow (liquid): ±0.10 %. Mass flow (gas): ±0.25 %. Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 2 200 000 kg/h (0 to 80 840 lb/min) |
Max. process pressure | PN 100, Class 600, 63K |
Medium temperature range | Standard: –50 to +150 °C (–58…+302 °F). Option: –50 to +240 °C (–58…+464 °F). High temperature option: –50 to +350 °C (–58…+662 °F). Option: –196 to +150 °C (–320 to +302 °F) |
Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F). Option: –60 to +60 °C (–76 to +140 °F) |
Sensor housing material | Standard: 1.4301 (304), corrosion resistant. Option: 1.4404 (316L). Sensor connection housing (standard): AlSi10Mg, coated. Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L |
Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonate |
Degree of protection | Sensor remote version (standard): IP66/67, type 4X enclosure. Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure. External WLAN antenna: IP67 |
Display/Operation | 4-line backlit display with touch control (operation from outside). Configuration via local display and operating tools possible |
Outputs | 4 outputs: 4-20 mA HART (active/passive), 4-20 mA WirelessHART, 4-20 mA (active/passive), Pulse/frequency/switch output (active/passive), Double pulse output (active/passive), Relay output |
Inputs | Status input, 4-20 mA input |
Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
Power supply | DC 24 V, AC 100 to 230 V, AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
Product safety | CE, C-tick, EAC marking |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025). Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation). MI-005 (Liquids other than water, Hydrocarbons, LPG, cryogenic liquids). NTEP (Liquids other than water, LPG, cryogenic liquids). MC (Liquids other than water, gases, cryogenic liquids). MI-002, PTB |
Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval, CCS approval |
Pressure approvals and certificates | PED, CRN, AD 2000 |
Material certificates | 3.1 material. NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK |
Hygienic approvals and certificates | cGMP |
Density Specifications
Measuring principle | Coriolis |
Product headline | Flowmeter with premium accuracy and robustness, as remote version with up to 4 I/Os. Highest measurement performance for liquids and gases under varying, demanding process conditions. |
Sensor features | Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space-saving installation – no in-/outlet run needs. Mass flow: measurement error ±0.05 % (PremiumCal). Medium temperature: –196 to 350 °C (–320 to 662 °F). Nominal diameter: DN 8 to 250 (³⁄₈ to 10"). |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Nominal diameter range | DN 8 to 250 (⅜ to 10") |
Wetted materials | Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022). Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022); 1.4301 (F304) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.10 % (standard), 0.05 % (option). Volume flow (liquid): ±0.10 %. Mass flow (gas): ±0.25 %. Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 2 200 000 kg/h (0 to 80 840 lb/min) |
Max. process pressure | PN 100, Class 600, 63K |
Medium temperature range | Standard: –50 to +150 °C (–58…+302 °F). Option: –50 to +240 °C (–58…+464 °F). High temperature option: –50 to +350 °C (–58…+662 °F). Option: –196 to +150 °C (–320 to +302 °F) |
Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F). Option: –60 to +60 °C (–76 to +140 °F) |
Sensor housing material | Standard: 1.4301 (304), corrosion resistant. Option: 1.4404 (316L). Sensor connection housing (standard): AlSi10Mg, coated. Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L |
Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonate |
Degree of protection | Sensor remote version (standard): IP66/67, type 4X enclosure. Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure |
Display/Operation | 4-line backlit display with touch control (operation from outside). Configuration via local display and operating tools possible |
Outputs | 4 outputs: 4-20 mA HART (active/passive), 4-20 mA WirelessHART, 4-20 mA (active/passive), Pulse/frequency/switch output (active/passive), Double pulse output (active/passive), Relay output |
Inputs | Status input, 4-20 mA input |
Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
Power supply | DC 24 V, AC 100 to 230 V, AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous area approvals | DC 24 V, AC 100 to 230 V, AC 100 to 230 V / DC 24 V (non-hazardous area) |
Density/Concentration Specifications
Measuring principle | Coriolis |
Product headline | Flowmeter with premium accuracy and robustness, as remote version with up to 4 I/Os. Highest measurement performance for liquids and gases under varying, demanding process conditions. |
Sensor features | Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space-saving installation – no in-/outlet run needs. Mass flow: measurement error ±0.05 % (PremiumCal). Medium temperature: –196 to 350 °C (–320 to 662 °F). Nominal diameter: DN 8 to 250 (³⁄₈ to 10"). |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Nominal diameter range | DN 8 to 250 (⅜ to 10") |
Wetted materials | Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022). Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022); 1.4301 (F304) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.10 % (standard), 0.05 % (option). Volume flow (liquid): ±0.10 %. Mass flow (gas): ±0.25 %. Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 2 200 000 kg/h (0 to 80 840 lb/min) |
Max. process pressure | PN 100, Class 600, 63K |
Medium temperature range | Standard: –50 to +150 °C (–58…+302 °F). Option: –50 to +240 °C (–58…+464 °F). High temperature option: –50 to +350 °C (–58…+662 °F). Option: –196 to +150 °C (–320 to +302 °F) |
Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F). Option: –60 to +60 °C (–76 to +140 °F) |
Sensor housing material | Standard: 1.4301 (304), corrosion resistant. Option: 1.4404 (316L). Sensor connection housing (standard): AlSi10Mg, coated. Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L |
Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonate |
Degree of protection | Sensor remote version (standard): IP66/67, type 4X enclosure. Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure |
Display/Operation | 4-line backlit display with touch control (operation from outside). Configuration via local display and operating tools possible |
Outputs | 4 outputs: 4-20 mA HART (active/passive), 4-20 mA WirelessHART, 4-20 mA (active/passive), Pulse/frequency/switch output (active/passive), Double pulse output (active/passive), Relay output |
Inputs | Status input, 4-20 mA input |
Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
Power supply | DC 24 V, AC 100 to 230 V, AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
Product safety | CE, C-tick, EAC marking |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025). Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation). MI-005 (Liquids other than water, Hydrocarbons, LPG, cryogenic liquids). NTEP (Liquids other than water, LPG, cryogenic liquids). MC (Liquids other than water, gases, cryogenic liquids). MI-002, PTB |
Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval, CCS approval |
Pressure approvals and certificates | PED, CRN, AD 2000 |
Material certificates | 3.1 material, NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK |
Hygienic approvals and certificates | 3-A, EHEDG, cGMP |