Application The innovative Promass X, featuring a patented four-tube design, delivers premium accuracy (0.05%) and exceptional performance for high-capacity operations, particularly in demanding onshore and offshore applications in the oil and gas industry. Its remote transmitter, the Promass X 500, enhances installation flexibility and ensures operational safety in harsh environments. The Heartbeat Technology guarantees reliable measurements and compliance with verification standards. The measuring principle is unaffected by fluid properties such as viscosity and density. It is ideal for high flow rates and provides exceptional performance in oil and gas applications, both onshore and offshore. Device Properties

  • Nominal diameter: DN 300 to 400 (12 to 16”)
  • Four-tube design with minimal pressure drop
  • Exterior made entirely of 1.4435 (316L) stainless steel
  • Remote version with up to 4 input/output connections
  • Backlit display with touch control and WLAN access
  • Standard cable connection between sensor and transmitter

Benefits

  • Enhanced profitability: Achieves premium accuracy for large volumes with a single installation point.
  • Reduced measuring points: Measures multiple variables, including flow, density, and temperature, in one device.
  • Space-efficient installation: No need for inlet or outlet runs.
  • Comprehensive process access: Numerous customizable I/Os and Ethernet connections for full access to diagnostic and process information.
  • Simplified system: Customizable I/O functions reduce complexity and system variation.
  • Built-in verification: Heartbeat Technology for continuous measurement reliability and integrated verification.

Documents

You may want to read this product's catalog. If so, please click to view the Proline Promass X 500 Series datasheet.

SPECIFICATIONS

Liquids Specifications

Measuring principle Coriolis
Product headline Highest capacity four-tube flowmeter, as remote version with up to 4 I/Os. For highest flow rates and outstanding performance in on/offshore oil and gas applications.
Sensor features Increased profit – single installation point providing premium accuracy for large quantities. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Nominal diameter: DN 300 to 400 (12 to 16"). Four-tube system with low pressure drop. Complete exterior design made of 1.4435 (316L).
Transmitter features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.
Nominal diameter range DN 300 to 400 (12 to 16")
Wetted materials Measuring tube: 1.4404 (316/316L)
Connection: 1.4404 (316/316L)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration
Max. measurement error Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 4100 t/h (0 to 4520 tn. sh./h)
Max. process pressure PN 100, Class 600
Medium temperature range –50 to +180 °C (–58 to +356 °F)
Ambient temperature range Standard: –40 to +60 °C (–40 to +140 °F)
Option: –60 to +60 °C (–76 to +140 °F)
Sensor housing material 1.4404 (316L), highest corrosion resistance
Sensor connection housing (standard): 1.4409 (CF3M), similar to 316L
Transmitter housing material AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
Degree of protection Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure
Display/Operation 4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Outputs 4 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Inputs Status input
4-20 mA input
Digital communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Power supply DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
Product safety CE, C-tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
MI-005 Liquids other than water (Hydrocarbons), LPG, cryogenic
MI-002, PTB
Marine approvals and certificates LR approval, DNV approval, ABS approval, BV approval, CCS approval
Pressure approvals and certificates PED, CRN
Material certificates 3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK

Gas Specifications

Measuring principle Coriolis
Product headline Highest capacity four-tube flowmeter, as remote version with up to 4 I/Os. For highest flow rates and outstanding performance in on/offshore oil and gas applications.
Sensor features Increased profit – single installation point providing premium accuracy for large quantities. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Nominal diameter: DN 300 to 400 (12 to 16"). Four-tube system with low pressure drop. Complete exterior design made of 1.4435 (316L).
Transmitter features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.
Nominal diameter range DN 300 to 400 (12 to 16")
Wetted materials Measuring tube: 1.4404 (316/316L)
Connection: 1.4404 (316/316L)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration
Max. measurement error Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 4100 t/h (0 to 4520 tn. sh./h)
Max. process pressure PN 100, Class 600
Medium temperature range –50 to +180 °C (–58 to +356 °F)
Ambient temperature range Standard: –40 to +60 °C (–40 to +140 °F)
Option: –60 to +60 °C (–76 to +140 °F)
Sensor housing material 1.4404 (316L), highest corrosion resistance
Sensor connection housing (standard): 1.4409 (CF3M), similar to 316L
Transmitter housing material AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
Degree of protection Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure
Display/Operation 4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Outputs 4 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Inputs Status input
4-20 mA input
Digital communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Power supply DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
Product safety CE, C-tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
MI-005 Liquids other than water (Hydrocarbons), LPG, cryogenic
MI-002, PTB
Marine approvals and certificates LR approval, DNV approval, ABS approval, BV approval, CCS approval
Pressure approvals and certificates PED, CRN
Material certificates 3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK

Density/Concentration Specifications

Measuring principle Coriolis
Product headline Highest capacity four-tube flowmeter, as remote version with up to 4 I/Os. For highest flow rates and outstanding performance in on/offshore oil and gas applications.
Sensor features Increased profit – single installation point providing premium accuracy for large quantities. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Nominal diameter: DN 300 to 400 (12 to 16"). Four-tube system with low pressure drop. Complete exterior design made of 1.4435 (316L).
Transmitter features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.
Nominal diameter range DN 300 to 400 (12 to 16")
Wetted materials Measuring tube: 1.4404 (316/316L)
Connection: 1.4404 (316/316L)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration
Max. measurement error Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 4100 t/h (0 to 4520 tn. sh./h)
Max. process pressure PN 100, Class 600
Medium temperature range –50 to +180 °C (–58 to +356 °F)
Ambient temperature range Standard: –40 to +60 °C (–40 to +140 °F)
Option: –60 to +60 °C (–76 to +140 °F)
Sensor housing material 1.4404 (316L), highest corrosion resistance
Sensor connection housing (standard): 1.4409 (CF3M), similar to 316L
Transmitter housing material AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
Degree of protection Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure
Display/Operation 4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Outputs 4 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Inputs Status input
4-20 mA input
Digital communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Power supply DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
Product safety CE, C-tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
MI-005 Liquids other than water (Hydrocarbons), LPG, cryogenic
MI-002, PTB
Marine approvals and certificates LR approval, DNV approval, ABS approval, BV approval, CCS approval
Pressure approvals and certificates PED, CRN
Material certificates 3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK
View AllClose