  • Datexel Signal Converter Dual Channel HART Compatible Hazardous Area Current Loop Repeater - DAT5030IS-BH
  • Signal Converter Dual Channel HART Compatible Hazardous Area Current Loop Repeater - DAT5030 IS-BH

Description

Datexel Signal Converter Dual Channel HART Compatible Hazardous Area Current Loop Repeater - DAT5030 IS-BH

Intrinsically Safe, DIP – switch configurable, HART Compatible, EMC compliant – CE mark - High Quality

The DAT 5030 IS device is a galvanic isolated Intrinsically Safety Barrier, defined as “Associated Apparatus”.

The input can measure 0-20 mA or 4-20 mA current loops, both active or passive mode; auxiliary power supply is available to supply the current loop through the hazardous area (ZONE 0).

The measure is converted in output as voltage signal (0-10V or 2-10V) or current signal (0-20mA or 4-20mA). auxiliary power supply is available to supply the current loop connected to the output.

The input and output range can be set by means of the dip-switch available on the side of the enclosure (see configuration table). The calibration of the device can be made by means of trimmer (ZERO and SPAN) available on the side of the enclosure.

DAT 5030 IS has a 3-way isolation: input (connected to hazardous area devices) is 2000 Vac isolated from power supply and output (connected to safe area);

power supply and output are 1500 Vac isolated between them.

The device must be powered with a voltage between 20 and 30 Vdc; the “PWR” green led turned on indicate the correct power supply.

The DAT 5030 IS /A model is single channel, when the DAT 5030 IS /B model has two channels isolated between then and with independent setting and calibration; with this model, connecting in serial loop the two inputs, it can obtain a signal duplicator.

The DAT 5030 IS /AH and DAT 5030 IS /BH models (single and double channel) are capable to transfer the bidirectional HART signal between input and output (the input must be active, that is the current loop must be powered by the auxiliary supply).

The DAT 5030 IS is housed in a rough self-extinguish plastic enclosure of 22.5 mm thickness suitable for DIN rail mounting.

The advantages and features for Datexel Signal Converter DAT5030IS-BH

  • Protection mode: II (1) G [ Ex ia Ga] IIC, II (1) D [ Ex ia Da] IIIC according to the Directive ATEX 2014/34/EU
  • Power supply for current loop in hazardous area (ZONE 0)
  • 0-20mA or 4-20mA active or passive configurable input
  • 0-10V, 2-10V, 0-20mA, 4-20mA configurable output
  • DIP – switch configurable
  • Single or Double Channel
  • HART Compatible on request
  • 2000 Vac galvanic isolation between input and output
  • EMC compliance – CE mark
  • DIN rail mounting suitable

Input for Datexel Signal Converter DAT5030IS-BH

  • Input signal Active or passive current loop
  • Range 0÷20 mA or 4÷20 mA configurable

Output Datexel Signal Converter DAT5030IS-BH

  • Output signal 4÷20 mA, 0÷20 mA, 0÷10 V or 2÷10 V configurable
  • Load resistance Voltage: > 5 KW Current: < 500 W
  • Auxiliary Supply > 12V @ 20mA
  • Power supply voltage (**) 20 ÷ 30 Vdc
  • Current consumption 80 mA per channel with Vaux operating
  • Polarity inverted protection 60 Vdc max

Performances

  • Calibration error ± 0.1 % f.s.
  • Linearity error (*) ± 0.2 % f.s.
  • Thermal drift 0.02 % f.s./°C
  • Response time < 0.2 sec.

Electromagnetic Compatibility (EMC)

  • ( for industrial environments ) Immunity: EN 61000-6-2; Emission : EN 61000-6-4
  • Operating temperature -20 ÷ 60 °C
  • Storage temperature -40 ÷ 85 °C
  • Relative humidity (not cond.) 0 ÷ 90%
  • Weight approx. 160 g

 

Series Information

Intrinsically safe smart series ATEX94/9/EC

The Intrinsically Safe SMART Series devices, type-approved according to Directive ATEX94/9/EC, are subdivided into three different product categories: universal input transmitters to be installed in a potentially explosive atmosphere (Zone 0) codes:

DAT 2015 IS, DAT 4035 IS, DAT 1010 IS, DAT 1015 IS, DAT 1065 IS.

Converters / Barriers for universal input or current loop (0-4…..20 mA), suitable for installation in safe zone for connections towards zone 0. codes:

DAT 4235 IS in the following versions:

A= Converter/Barrier, B= Double trip amplifier,

C= Converter/Barrier + Double trip amplifier.

DAT 5030 IS in the following versions:

A= Single-channel barrier, AH= HART transparent single-channel

barrier, B= Double-channel barrier, BH= HART transparent

double-channel barrier.

About Datexel:

Founded in 1992 from the commitment and aspiration of several partners as a small provincial company, through the years DATEXEL has become an established reality on Italian and international markets as a manufacturer of electronic equipment for industrial automation and control process.

The range of DATEXEL products includes: Transmitters, signal and temperature Converters (both analogue and digital), galvanic Isolators, signal Splitters, I/O Modules, Trip Amplifiers, Power Supply Units, current loop Isolators, analogue and digital Displays.

Documents

To View Data Sheet for Datexel Signal Converter Dual Channel HART Compatible Hazardous Area Current Loop Repeater - DAT5030IS-BH Please Click Here
View AllClose

Warranty Information

One Year Warranty
View AllClose

Additional Information

Input:
2 X 4-20mA, 0-20mA HART
Output:
2 X Voltage 0-10V, 2-10V, 2 X Current 4-20mA, 0-20mA, HART
Power Supply:
18 to 32 Vdc. Reverse polarity protection 60 Vdc
Current Consumption:
Current output 35 mA max. Voltage output 25 mA max
Temperature rating:
Operative-4°F +158°F - 20°C +70°C Temperature Storage Temperature - 40°F+185°F - 40°C+85°C.
Humidity:
(non condensing) 0-90%
Housing:
Material self-extinguishing
Dimensions:
3 1/2" x 4 1/2 " x 1/2", 90 x 112x x 12.5 mm
Weight::
160 g
EMC:
For industrial environments. Immunity: EN 61000-6-2. Emission: EN 61000-6-4
Configuration:
PC Configurable and DIP Switch Configurable